Documentation record
Registered dimensions (L × B × D)73.6 ft × 25.0 ft × 9.7 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALBINA ENGINE & MACHINE · PORTLAND, OR, UNITED STATES · built 1971
Hull materialSteel
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORTLAND, OR
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 29 June 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Net Ton
98 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 27
4 December 2025
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8277479
20 August 2025
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8214963
10 October 2024
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7965406
12 October 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7784857
15 July 2022
Initial Certification · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7507584
5 August 2021
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7278328
5 November 2013
Industry Initiated Exam · Deficiency Check · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4739721
21 September 2012
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4456437
29 April 2011
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4004085
2 April 2010
Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3716006
27 January 2010
Industry Initiated Exam · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3670741
1 May 2008
DAPI Audit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3196839
15 January 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3130743
23 March 2007
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2895347
13 March 2007
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2888020
29 November 2006
Deficiency Check · Uninspected Other · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2833992
16 May 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2650714
28 February 2005
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2300864
5 November 2004
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2235522
10 June 2004
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2094488
27 May 2004
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2081352
13 February 2004
Type not recorded
No type recorded · USCGC PETREL (WPB 87350) · USCG Southwest District (CGD-SW) · Activity 2008823
3 August 2002
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1906207
20 February 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 730472
29 January 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 92060
31 October 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 707031
29 September 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 371949
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 August 2025
Resolved
Port fuel tank was found wasted, submit repair plan for approval.
Repair plan submitted and approved for repair NLT 31OCT2026. See documents
Action required: 705 - Other - as specified
Due 31 October 2026
Resolved 22 June 2026
Resolution: Repairlan submitted Drydock due Oct
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 October 2023
Resolved
Fixed fire-extinguishing systems, including ventilation, machinery shutdowns, and fixed fire-extinguishing system pressure-operated dampers on board the vessel, must be inspected or tested at least once every 12 months. Fixed CO2 system for engine room has not had annual servicing completed and is three months over due.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 October 2023
Resolution: Vessel completed annual servicing with break water.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 12 October 2023
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: High bilge levels. Vessels bilge alarm in the engine room is not working as required.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 October 2023
Resolution: Vessel repaired bilge level alarm for engine room.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 October 2023
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. Fuel filters in the engine room that have drain valves in the bottom do not have plugs in the bottom further preventing fuel from being drained into the bilge by accident.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2023
Resolved 7 November 2023
Resolution: New drain valves were installed with plugs attached.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 October 2023
Resolved
Each vessel must be designed and constructed to minimize fire hazards insofar as reasonable and practicable. Aft engine room door does not latch freely and dogs do not work as designed that would prevent CO2 from working properly within the space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2023
Resolved 7 November 2023
Resolution: Dogs to aft engine room door locked into the new seal properly. Latch shut satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 12 October 2023
Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040. Four rocket projectiles, each complete with bridle and leader of fire-resistant materials. Two of the projectiles shall be of the buoyant type. Vessel only has two rocket projectiles.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2023
Resolved 7 November 2023
Resolution: Vessel was provided (2) additional rocket projectiles.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 12 October 2023
Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040. (2) An auxiliary line that: (i) Is at least 450 meters (1,500 feet) long; (ii) Has a breaking strength of at least 40 kilonewtons (9,000 pounds-force); and (iii) Is, if synthetic, of a dark color or certified by the manufacturer to be resistant to deterioration from ultraviolet light. Vessel does not have required aux. line.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2023
Resolved 7 November 2023
Resolution: Vessel was provided 1,500 feet of auxiliary line for line throwing appliance.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2023
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. 01 Port side main deck light fixture is broken.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2023
Resolved 7 November 2023
Resolution: Vessel installed new main deck lighting fixture. Tested satisfactory.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 July 2022
Resolved
ALL OWNERS OF MORE THAN 1 EXISTING VSL MUST ENSURE THE VSL IS ISSUED A VALID COI NLT 19 JULY 2022 AS PER SUB M PHASE IN SCHEDULE.
VSL IS RESTRICTED FROM MOVEMENT UNTIL A COI INSPECTION IS COMPLETED AND THE VSL IS ISSUED A COI FROM THE [name withheld]
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 August 2022
Resolution: Conducted initial inspection for certification.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 August 2021
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the associated fleet that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 November 2021
Resolved 26 August 2021
Resolution: Co only needed def issued to 1 vessel. Removed this one. Co at 9 of 13.
Documentation › Logs/Records › Drug Test Records
Issued 2 April 2010
Resolved
Supervisors have no proof of 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR 16.401.
Due 30 April 2010
Resolved 4 June 2010
Documentation › Logs/Records › Logbook (official)
Issued 29 November 2006
Resolved
log pre underway tests
Action required: 705 - Other - as specified
Resolved 28 August 2007
Resolution: company developed checklist for incorporation into smooth log.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 29 November 2006
Resolved
service fixed co2 system
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 December 2006
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 29 November 2006
Resolved
install vent closure in engine room
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 December 2006
Documentation › Logs/Records › Garbage Recordkeeping
Issued 29 November 2006
Resolved
post garbage plan
Due 29 December 2006
Resolved 13 March 2007
Electrical › Electric Supply System (service) › Cable
Issued 29 November 2006
Resolved
cover open electrical boxes and recepticals
Due 29 December 2006
Resolved 13 March 2007
Engineering › Fuel Oil Service System › Valve
Issued 29 November 2006
Resolved
install fuel oil shut offs
Due 29 December 2006
Resolved 23 March 2007
Resolution: test sat
Fire Fighting › Fire Pumps › Power Source
Issued 29 November 2006
Resolved
provide remote fire pump start
Due 29 December 2006
Resolved 23 March 2007
Resolution: remote start/stop installed
Accommodation/Occupational Safety
Issued 29 September 1994
Resolved
ON 29SEP94, THE MASTER, PAUL C. DIGGS JR. OF THE DOCUMENTED TOWING VESSEL MEA'E OWNED BY HAWAIIAN TUG AND BARGE CORP., A U.S. DOCUMENTED OCEANGOING SHIP GREATER THAN 40 FEET IN LEGNTH AND USED FOR COMMERCE, WAS NOT MAINTAINING A RECORD OF GARBAGE DISCHARGE OPERATIONS.
Condition: Unknown
Due 29 September 1994
Resolved 31 October 1994
Documentation
Issued 29 September 1994
Resolved
ON 29SEP94 PAUL C. DIGGS JR. MASTER OF THE MEA'E WHO IS THE PERSON IN CHARGE OF THE VESSEL WAS NOT ABLE TO PRODUCE A VALID CERTIFICATE OF DOCUMENTATION AS REQUIRED BY 46 C.F.R. 45-5 AND 46 C.F.R 45-7.
Condition: Unknown
Due 29 September 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past