Records from 1996 to 2021. Most recent: operational control imposed, 13 July 2021.
Inspection history · 21
12 July 2021
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7254429
18 March 2021
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7158863
24 September 2020
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7064600
24 September 2020
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7075692
22 January 2015
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5056946
13 March 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4822568
2 March 2012
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4255048
27 February 2012
Industry Initiated Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4254309
9 December 2011
Type not recorded
No type recorded · Violation Case Coordination Center · Activity 4205112
3 December 2011
Type not recorded
No type recorded · Station Venice · USCG Heartland District (CGD-H) · Activity 4200724
18 August 2005
Annual Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2475681
23 December 2004
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 2276180
21 January 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1989978
30 August 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1896625
30 August 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1989398
25 April 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1780489
25 April 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1780503
25 April 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1780507
12 April 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1773447
21 February 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214581
18 September 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 157142
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 July 2021
No resolution recorded
All seals and gaskets must be properly maintained to
prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. Found excessive oil in bilge. Vessel shall determine cause of leaks, repair and clean.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 13 July 2021
No resolution recorded
The condition of the vessel and its equipment must be
acceptable to the cognizant OCMI. Vessel was found to
have holes in bulwarks and leak in aft void tanks. Vessel must identify all areas of wastage and submit repair proposal.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 July 2021
No resolution recorded
Each towing vessel must be fitted with a general alarm that is activated at each operation station and can notify persons onboard in the event of an emergency. Vessel general alarm is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 July 2021
No resolution recorded
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
Batteries and battery charger in engine room are unsecured.
Condition: Placed in Improper Service
Action required: 30 - Ship detained
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 July 2021
No resolution recorded
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Both main propulsion engines have no cover over flywheel.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 26 July 2021 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 March 2021
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the 75% of the vessels that has not obtained a valid COI. This vessel was given 90 days to complete the required COI inspection, but failed to do so. The vessel shall be made available for a Coast Guard COI inspection prior to vessel movement. The vessel is no longer allowed to operate until cleared by the US Coast Guard.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 16 June 2021
Resolved 1 May 2023
Resolution: Deficiency closed due to length of time in unresolved status. Ensure deficiency is inspected for compliance upon future inspection.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 14 October 2020
Resolved
Decks and bulkheads designed to be watertight or weathertight must be maintained in that condition. The engine room starboardside forward overhead deck under the accommodation space/galley has a 6inch by 9 inch deteriorated hole. Submit repair plan proposal to OCMI for approval.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 October 2020
Resolved 22 October 2020
Resolution: Vessel rep repaired the wasted steel, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo ports and other similar openings
Issued 14 October 2020
Resolved
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. Approximately 2 feet of water present in the forepeak, remove water.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 October 2020
Resolved 22 October 2020
Resolution: Water removed from the forepeak
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 14 October 2020
Resolved
A towing vessel must carry adequate and up-to-date charts, maps and nautical publications for the intended voyage. Publications onboard were not up-to-date and were dated 2017.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2020
Resolved 22 October 2020
Resolution: vessel provided updated pubs
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 September 2020
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. Found excessive oil in bilge. Vessel shall determine cause of leaks, repair and clean.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 24 October 2020
Resolved 14 October 2020
Resolution: Vessel cleaned out all of the bilges.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 September 2020
Resolved
Each towing vessel must have a self-priming, power-driven, fixed fire pump. No fixed or portable fire pump.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 24 October 2020
Resolved 14 October 2020
Resolution: Vessel provided a portable fire pump and witnessed the pump run, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
Open ended/uninsulated wires throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 24 October 2020
Resolved 14 October 2020
Resolution: Vessel rep removed the loose wires in the bilge.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 24 September 2020
Resolved
All portable fire extinguishers, semi-portable fire-extinguishing systems, fire-detection systems, and fixed fire-extinguishing systems, including ventilation, machinery shutdowns, and fixed fire-extinguishing system pressure-operated dampers on board the vessel, must be inspected or tested at least once every 12 months.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 24 October 2020
Resolved 14 October 2020
Resolution: Vessel rep provided third party service report.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 September 2020
Resolved
Each lifejacket must have a lifejacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the lifejacket.
All lights on jackets were expired or missing.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 24 October 2020
Resolved 14 October 2020
Resolution: All lights replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 September 2020
Resolved
All machinery and equipment that is not in proper working order (including missing or malfunctioning guards or safety devices) must be removed; made safe through marking, tagging, or covering; or otherwise made unusable. Both main propulsion engines have no cover over flywheel.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 24 October 2020
Resolved 14 October 2020
Resolution: guard was installed over both flywheels
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 September 2020
Resolved
A towing vessel must carry lifebuoys as follows: Be approved under approval series 160.050 or 160.150. lifebuoys were deteriorated and improper battery installed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 October 2020
Resolved 14 October 2020
Resolution: vessel rep replaced, all sat
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 September 2020
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarm must be provided: high bilge levels. Alarms must be visible and audible at each operating station. The bilge alarm was not operable nor visible and audible at the operating station.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 October 2020
Resolved 22 October 2020
Resolution: tests functioned properly
Fire Fighting › Fire Hoses › Condition
Issued 22 January 2015
Resolved
Fire hose not attached or readily available.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 23 January 2015
Resolution: Pump stored with hose attached.
Fire Fighting › Fire Pumps › Capacity
Issued 22 January 2015
Resolved
Fire pump not operational.
Action required: 705 - Other - as specified
Resolved 23 January 2015
Resolution: Company replaced fire pump and demonstrated that it was operational.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 22 January 2015
Resolved
Fixed fire detection system is non operational.
Action required: 705 - Other - as specified
Resolved 23 January 2015
Resolution: Fire detection system was serviced satisfactorily.
Engineering › Bilge Water Management System › Not Installed
Issued 22 January 2015
Resolved
Excessive accumulation of fuel in the bilges
Action required: 705 - Other - as specified
Resolved 23 January 2015
Resolution: Oil was removed via comapny''s vac truck.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 22 January 2015
Resolved
Master held expired credential with improper endorsement while operating in the Western Rivers. Relief Capt required.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 22 January 2015
Resolution: Relief captain with valid credential and correct endorsements contacted the Op Two To Tango Division from vessel phone.