← All vessels
KRITI BAY
KRITI BAY is a 2010 tank ship. The Coast Guard has recorded 33 inspections since 2010, most recently in October 2023, along with 14 deficiencies and 13 operational controls.
Records from 2010 to 2023. Most recent: inspection, 10 October 2023.
- Built
- 2010
- Last inspected
- 10 October 2023
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 14 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9418573 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
A8RF5
1077877
Flag
LIBERIA
—
Maury page id
psix-1077877
Inspections, by type
…with no type recorded10
Years with a record
11 calendar years (2010–2023)
The 33 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it49499 - Dead Weight, Metric Ton
59767 - Displacement, Metric Ton
29734 - Convention (Subpart B), Gross Ton
13013 - Convention (Subpart B), Net Ton
59767 - Displacement, Metric Ton
29734 - Convention (Subpart B), Gross Ton
13013 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 33
10 October 2023
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7805808
19 September 2023
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7791047
6 February 2023
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7632939
26 September 2022
PSC B · COC-CHEM & TVE Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7566133
24 July 2022
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7514799
14 April 2022
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7431248
11 April 2022
Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7428559
12 October 2021
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7330735
12 October 2021
Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7331026
31 August 2021
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7300896
23 July 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7265632
21 July 2021
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7263795
2 July 2021
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7242854
29 January 2021
COC-CHEM & TVE Annual · PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7129822
24 January 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7129910
17 August 2019
COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6787750
15 August 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6513070
2 August 2018
ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6488000
25 July 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6490754
3 July 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6453105
2 April 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6383582
13 March 2018
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6371312
5 March 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6366234
22 February 2018
Deficiency Check · Administrative Inspection · Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6351765
13 April 2017
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6123936
9 April 2017
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6121132
22 November 2016
COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6045228
25 September 2015
Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5728815
29 May 2014
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4873740
14 July 2011
COC-CHEM Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4073926
10 December 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3908068
26 November 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3899033
20 November 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3891586
Deficiency record · 14
08 - Alarms › N/A - No Subsystem › General alarm
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
PSCO observed an audible/visual general annunciator indicator in engine space next to the shaft was inoperable.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 September 2022
Resolved
The main door to the engine control room, an A-60 door, was deteriorated and in need of replacement. Door no longer operates as intended.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 11 April 2022
Resolved
IG System shall be capable of delivering inert gas with an oxygen of not more than 5% to the cargo tanks at any flow rate. IG system was unable to deliver proper inert gas flow rate to maintain cargo operations. This resulted in a loss of pressure and shut down. PSCO observed 02 spikes in oxygen while on board.
FSS 15.2.2.1.2.5
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 11 April 2022
Resolved
A water seal shall be capable of maintaining an adequate supply at all times. PSCO observed 03 low level alarms on deck water seal while on board.
FSS 15.2.2.3.1.4
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 October 2021
Resolved
The machinery shall be adequate for the service which it is intended. Vessel experienced a main engine malfunction.
74SOLAS(20)II-1/26 Action 60ac
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 29 January 2021
Resolved
For tankers of 20,000 tons deadweight and upwards be capable of preventating dangerous accumulation of explosive mixtures. PSCO observed that ships crew installed a fixed piping connection between the N2 system and the IG main. Request clarification Certificate issuing authority. Rectify prior to cargo operations.
SOLAS 74 amend II-2 5.5 & 5.5.4
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 29 January 2021
Resolved
For tankers 20,000 tonnes deadweight and upwards shall be designed, constructed, and tested to the satisfaction of administration. PSCO observed that there was no double block/bleed located in the hazardous zone. Prior to putting N2 system into service properly instal iaw SOLAS 74 amend II-2 5.5 & 5.5.4
Electrical › Lighting (service) › Lighting Fixture
Issued 1 March 2018
Resolved
1135 - Electrical installations shall be such as to minimize the risk of fire and explosion from flammable products.
PSCOs found 7 explosion-proof lights within hazardous area that are no longer functioning as designed - 1 tube type light with water, salt, and debris inside near starboard side forecastle, 3 globe type lights with dead bugs inside in sample locker room, and 3 globe lights with dead bugs inside cargo tank seawater heater room.
(17ac) 74 SOLAS 14 VII/10.1 REF IBC 10.1.2.1
Documentation › Certificates/Documents › International Certificate of Fitness (IBC Code)
Issued 22 February 2018
Resolved
1135 - An international Certificate of Fitness (COF) for the carriage of dangerous chemicals in bulk shall be issued to a chemical tanker engaged in international voyages. The Certificate shall be drawn up in the form corresponding to the model given in the appendix.
Vessel is currently loaded with 2,525 m³ of acetone, a Chapter 18 cargo, in tank #1. Acetone is not listed on the vessel's COF or COF addendum (Vessel does not have a separate IPPC-NLS for Chapter 18 cargoes). This constitutes transport of a substance not authorized/mentioned in the vessel's COF.
(74 SOLAS 14 VII/10.1 REF IBC 1.5.4) (30abc)
Deck/Cargo › Cargo Stowage › General
Issued 22 February 2018
Resolved
1135 - The quantity of cargo required to be carried in a type II ship shall not exceed 3,000 m³ in any one tank.
Vessel currently has 3,180 m3 of 1,3 Cyclopentadiene dimer (molten) in tank #6P. 1,3 Cyclopentadiene dimer (molten) must be carried on a ship type II per column “e” of chapter 17 of the IBC.
(74 SOLAS 14 VII/10.1 REF IBC 16.1.2) (30abc)
Deck/Cargo › Inert Gas System › Deck Distribution System
Issued 22 February 2018
Resolved
1850 - For tankers of = 20,000 DWT, the protection of cargo tanks shall be achieved by a fixed inert gas system IAW the requirements of the FSS Code. The system shall be operated as to render and maintain the atmosphere of the cargo tanks non-flammable at all times, except when such tanks are gas free.
Vessel is 49,999 DWT. #1 -#6 port and starboard cargo tanks are >3,000m³ in size so exemption from IG requirements in SOLAS II-2/4.5.5.2.2 does not apply.
Vessel is currently loaded with acetone (1P) and benzene (2P, 2S, 3P, 3S, 4P, 4S, 5P, 5S, 6S). Both cargoes have a flashpoint <60°C (Acetone -9.4°C, Benzene -11°C). Crew stated that tanks were not inerted prior to loading. PSCOs witnessed measuring of O2 content in tanks and found multiple tanks in the flammable range (tanks 4P, 3P, 2P, and 2S at 15.3%, 15.5%, 15.0%, and 16.6% respectively).
(74 SOLAS 14 II-2/4.5.5 REF 2007 FSS 15.2.1.2)
(30abc)
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 22 February 2018
Resolved
2535- The company should establish procedures procedures, plans and instructions, including checklists as appropriate, for key shipboard operations. SMS CHP-001-7/42 Section 1.8.5(g) states that “for tanks in excess of 3,000m³ and cargo with a flashpoint of 60°c, tanks must be inerted before loading". This procedure is also incorporated in checklist CHP-FM03, item #25.
Vessel is currently loaded with acetone (1P, flashpoint -9.4°c) and benzene (2P, 2S,3P,3S,4P,4S,5P,5S,6S; flashpoint -11°c). All aforementioned tanks are >3,000m³ in size. Tanks were not inerted prior to loading and during exam PSCOs found multiple tanks to have O2 content of >15% by volume.
(74 SOLAS 14 IX/3.1 REF ISM 7) (30bc)
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 22 February 2018
Resolved
Each vessel vapor connection flange face must have a 1/2" diameter permanent stud projecting outward at least 1 inch long.
All 4 vapor connection flange faces lack a permanently affixed stud. PSCOs were able to unscrew and remove bolts by hand. All bolts were not projecting outward and one flange's hole was not aligned with stud.
(16c) 46 CFR 39.2001 (j)
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 14 July 2011
Resolved
0899-Other acid prev.- Each transfer pipe must not leak under static liquid pressure at least 1.5 times the maximum allowable working pressure. Vessel could not provide documentation attesting to satisfactory liquid pressure test of the bunker pipes or cargo pipes. Provide documentation to the CG prior to bunkering or cargo operations. -33CFR156.170
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.