Records from 2016 to 2025. Most recent: inspection, 26 September 2025.
Inspection history · 22
26 September 2025
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8239461
26 September 2025
COE-Administrative
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8241793
21 January 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8066846
12 December 2024
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8044346
12 December 2024
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8046519
15 July 2023
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7742950
11 July 2022
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7497171
21 March 2022
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7415525
24 December 2021
In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7374163
17 December 2021
PSC B
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7364445
11 July 2021
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7252517
7 May 2021
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7191507
23 October 2020
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7082793
19 September 2019
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6813025
2 April 2019
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6654654
13 December 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6597037
4 April 2017
Ballast Water Examination · NPV Safety Exam · Random ISPS/MTSA/PSC
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6117708
30 March 2017
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6116455
25 August 2016
ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5983201
25 May 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5886859
30 April 2016
Type not recorded
No type recorded · Station Alexandria Bay · USCG Great Lakes District (CGD-GL) · Activity 5866056
29 April 2016
Ballast Water Examination · COE-Offshore · ISPS III Exam · Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5885884
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 12 December 2024
Resolved
Life boat launching appliances shall be capable of recovering the lifeboat with its crew. The vessel's davit system is inoperable and unable to recover lifeboat.
74SOLAS(2020)III/34
LSA Code 6.1.1.8
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 December 2024
Resolved 12 December 2024
Resolution: Flag dispensation issued for Rescue Boat. Sector Charleston reissued Form B to a 40ac.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 12 December 2024
Resolved
Emergency generating sets arranged to be automatically started shall be equipped with a stored energy capability of at least three consecutive starts. Emergency generator battery set was unable to start the emergency generator.
74SOLAS(2020)II-2/44.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 December 2024
Resolution: Crew replaced the emergency generator batteries.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 12 December 2024
Resolved
Each rescue boat launching appliance shall be fitted with a p powered winch motor capable of raising the rescue boat from the water. The vessel's rescue boat davit system is inoperable and unable to recover the rescue boat. 74SOLAS(2020)III/34 - LSA Code 6.1.1.9
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 December 2024
Resolved 21 January 2025
Resolution: Class report was received attesting to the repair and proper operation to the vessels davit launch system for the vessels rescue boat. See attach Class report for further information.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 December 2021
Resolved
AFTER ANY SURVEY, NO CHANGE SHALL BE MADE TO A SHIPSTRUCTURE/ARRANGEMENT WITHOUT SANCTION OF THE ADMINISTRATION. IT WAS REPORTED THAT THE VESSEL ALLIDED WITH A PIER ON DURING ITS DEPARTURE FROM THE MSU TOLEDO ZONE, CAUSING DAMAGE TO THE SIDESHELL ON THE STARBOARD QUARTER OF THE VESSEL. THE VESSEL MASTER STATED THAT NO DAMAGE WAS NOTED TO THE INTERNAL FRAMEWORK AND THAT NO PENETRATIONS WERE FOUND IN THE SIDESHELL. THE VESSEL WAS NO LONGER IN THE MSU TOLEDO ZONE WHEN THE REPORT WAS RECEIVED.
31DEC2021: Due date updated to reflected DNV requirement for permanent repairs.
Action required: 705 - Other - as specified
Due 2 May 2022
Resolved 19 January 2022
Resolution: Permanent repairs have been completed to the satisfaction of Class.