← All vessels
TALARA
TALARA is a 2010 tank ship. The Coast Guard has recorded 23 inspections since 2010, most recently in November 2024, along with 12 deficiencies and 10 operational controls, 1 with no removal date recorded.
Records from 2010 to 2024. Most recent: inspection, 8 November 2024.
- Built
- 2010
- Last inspected
- 8 November 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 12 recorded · 0 without a recorded resolution
- Controls
- 1 with no removal date recorded
Identity
9569994 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7TW5
1079481
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1079481
Inspections, by type
…with no type recorded7
Years with a record
10 calendar years (2010–2024)
The 23 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it89187 - Displacement, Metric Ton
73371 - Dead Weight, Metric Ton
42010 - Convention (Subpart B), Gross Ton
22361 - Convention (Subpart B), Net Ton
73371 - Dead Weight, Metric Ton
42010 - Convention (Subpart B), Gross Ton
22361 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 23
8 November 2024
PSC B · COC-TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8031749
2 October 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6826620
28 August 2019
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6797366
24 August 2019
Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6790451
20 July 2018
COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6482297
27 May 2018
COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6425106
23 April 2018
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6397765
4 November 2017
COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6297621
26 October 2016
COC-CHEM & TVE Renew · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6029817
25 October 2016
COE-Offshore
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6029702
21 October 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6027133
11 September 2015
Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5232516
22 August 2014
COC-TVE Renew · COE-Dockside · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4948231
26 June 2014
ISPS I Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4900177
26 June 2014
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4900595
14 May 2014
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4858543
15 July 2012
COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4364340
26 January 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3933746
26 January 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3945846
13 November 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3891757
18 October 2010
Deficiency Check · ISPS I Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3871773
14 October 2010
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3864850
14 October 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3870063
Deficiency record · 12
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 8 November 2024
Resolved
The machinery and other pressure vessels, associated piping systems, and fittings shall be of a design and construction adequate for the service for which they are intended
PSCO observed inert gas system scrubber leaking water from seawater inlet piping.
74Solas(20) II-1/26.1
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 August 2019
Resolved
07105 - Fire Safety - Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self-closing. Self-closing door leading to steering gear room was unoperational.
74SOLAS09CHII-2/REG 9.4.2.1
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 24 August 2019
Resolved
10103 - Safety of Navigation - All ships of 3,000 gross tonnage and upwards shall in addition to meeting the requirements of paragraph 2.5. have a 3 GHz radar.
74SOLAS14CONSCHV/REG 19.2.7.1
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 4 November 2017
Resolved
WHERE THE EMERGENCY SOURCE OF ELECTRICAL POWER IS A GENERATOR, IT SHALL BE STARTED AUTOMATICALLY UPON FAILURE OF THE MAIN SOURCE OF ELECTRICAL POWER SUPPLY. DURING FAILURE POWER TEST EMERGENCY GENERATOR FAILED TO AUTOMATICALLY START. 74 SOLAS (2014) II-1/REG 43.3.1.2. 10c
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 4 November 2017
Resolved
EACH EMERGENCY GENERATOR SET ARRANGED TO BE AUTOMATICALLY STARTED SHALL BE EQUIPPED WITH THE STARTING DEVICES APPROVED BY THE ADMINISTRATION WITH A STORED ENERGY CAPABILITY OF ATLEAST THREE CONSECUTIVE STARTS. A SECOND SOURCE OF ENERGY SHALL BE PROVIDED FOR AN ADDITIONAL THREE STARTS WITHIN 30 MIN. SECONDARY MEANS OF START (BATTERY) FAILED TO START EMERGENCY GENERATOR. 74 SOLAS (2014) II-1/REG. 44/2 10c
Electrical › Electric Generation Source (emergency) › Generator
Issued 11 September 2015
Resolved
Emergency generating sets arranged to be started automatically shall provide a second source of energy for an additional three starts withing 30 min. Secondary start hydraulic pump on E-gen does not function, lost pressure and leaking hydraulic fluid. 74SOLAS(2014 Cons)II-1/44.2 10c
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 11 September 2015
Resolved
After any survey has been completed no change shall be made in machinery or other items covered by the survey. Ships incinerator insulation and heat portection is damaged, cracked and missing. 74SOLAS(2014 Cons)CH 1/11(b) 40ac
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 11 September 2015
Resolved
Fire fighters outfits shall comply with the FSS Code. Personal equipment shall consist of protective clothing of material to protect the skin from heat radiating from the fire. 02 Fire fighting outfits have tears in the protective outer layer. 74SOLAS(2014 Cons)Ch II-2/10.1.1 FSS Code CH 3.2.1.1.1 17ac
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 15 July 2012
Resolved
0299- Other(Crew)- PSCO observed that there was no records for Ballast Water Management training. Provide copy of training records to USCG. -33CFR151.2035
Operations/Management › Drills/Instruction › Not Conducted
Issued 15 July 2012
Resolved
0299- Other(Crew) - PSCO observed that there was no training records for the Vessel General Permit. -40CFR122.2
Deck/Cargo › Inert Gas System › Gas Regulating Valve
Issued 15 July 2012
Resolved
1840- Instrumentation- For inert gas systems of both flue gas type and the inert gas generator type, audible and visual alarms shall be provided to indicate. PSCO observed that the IG Main gas pressure low level alarm is set at 50 mmWG per the IG mainual. -FSS Code 2.4.3.1.8
Documentation › Certificates/Documents › IOPP Certificate
Issued 15 July 2012
Resolved
0150- IOPP- The government of a party to the present convention may, at the request of the administration, cause a ship to be surveyed. PSCO observed that the endorsement for the thru put of the Oily Water Separator was not annotated on the IOPP Form B Supplement. -MARPOL 73/78 Annex I/8
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.