MAURY USCG vessel records Sign in
← All vessels

TALARA

TALARA is a 2010 tank ship. The Coast Guard has recorded 23 inspections since 2010, most recently in November 2024, along with 12 deficiencies and 10 operational controls, 1 with no removal date recorded.

Records from 2010 to 2024. Most recent: inspection, 8 November 2024.

Built
2010
Last inspected
8 November 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9569994 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1079481
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1079481

Inspections, by type

…with no type recorded7
Years with a record 10 calendar years (2010–2024)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it89187 - Displacement, Metric Ton
73371 - Dead Weight, Metric Ton
42010 - Convention (Subpart B), Gross Ton
22361 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 23

8 November 2024 PSC B · COC-TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8031749
2 October 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6826620
28 August 2019 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6797366
24 August 2019 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6790451
20 July 2018 COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6482297
27 May 2018 COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6425106
23 April 2018 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6397765
4 November 2017 COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6297621
26 October 2016 COC-CHEM & TVE Renew · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6029817
25 October 2016 COE-Offshore
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6029702
21 October 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6027133
11 September 2015 Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5232516
22 August 2014 COC-TVE Renew · COE-Dockside · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4948231
26 June 2014 ISPS I Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4900177
26 June 2014 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4900595
14 May 2014 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4858543
15 July 2012 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4364340
26 January 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3933746
26 January 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3945846
13 November 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3891757
18 October 2010 Deficiency Check · ISPS I Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3871773
14 October 2010 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3864850
14 October 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3870063

Deficiency record · 12

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 8 November 2024 Resolved
The machinery and other pressure vessels, associated piping systems, and fittings shall be of a design and construction adequate for the service for which they are intended PSCO observed inert gas system scrubber leaking water from seawater inlet piping. 74Solas(20) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2024
Resolved 14 November 2024
Resolution: Vessel sent in documentation and service report of repairs to leaking pipe.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 August 2019 Resolved
07105 - Fire Safety - Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self-closing. Self-closing door leading to steering gear room was unoperational. 74SOLAS09CHII-2/REG 9.4.2.1
Action required: 10 - Deficiency Rectified
Resolved 28 August 2019
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 24 August 2019 Resolved
10103 - Safety of Navigation - All ships of 3,000 gross tonnage and upwards shall in addition to meeting the requirements of paragraph 2.5. have a 3 GHz radar. 74SOLAS14CONSCHV/REG 19.2.7.1
Action required: 15 - Rectify deficiencies by next port
Resolved 28 August 2019
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 4 November 2017 Resolved
WHERE THE EMERGENCY SOURCE OF ELECTRICAL POWER IS A GENERATOR, IT SHALL BE STARTED AUTOMATICALLY UPON FAILURE OF THE MAIN SOURCE OF ELECTRICAL POWER SUPPLY. DURING FAILURE POWER TEST EMERGENCY GENERATOR FAILED TO AUTOMATICALLY START. 74 SOLAS (2014) II-1/REG 43.3.1.2. 10c
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 November 2017
Resolution: Corrected on the spot
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 4 November 2017 Resolved
EACH EMERGENCY GENERATOR SET ARRANGED TO BE AUTOMATICALLY STARTED SHALL BE EQUIPPED WITH THE STARTING DEVICES APPROVED BY THE ADMINISTRATION WITH A STORED ENERGY CAPABILITY OF ATLEAST THREE CONSECUTIVE STARTS. A SECOND SOURCE OF ENERGY SHALL BE PROVIDED FOR AN ADDITIONAL THREE STARTS WITHIN 30 MIN. SECONDARY MEANS OF START (BATTERY) FAILED TO START EMERGENCY GENERATOR. 74 SOLAS (2014) II-1/REG. 44/2 10c
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 4 November 2017
Resolution: Corrected on the spot
Electrical › Electric Generation Source (emergency) › Generator
Issued 11 September 2015 Resolved
Emergency generating sets arranged to be started automatically shall provide a second source of energy for an additional three starts withing 30 min. Secondary start hydraulic pump on E-gen does not function, lost pressure and leaking hydraulic fluid. 74SOLAS(2014 Cons)II-1/44.2 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 September 2015
Resolved 11 September 2015
Resolution: Secondary means of starting E-gen repaired while PSC team on board.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 11 September 2015 Resolved
After any survey has been completed no change shall be made in machinery or other items covered by the survey. Ships incinerator insulation and heat portection is damaged, cracked and missing. 74SOLAS(2014 Cons)CH 1/11(b) 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 September 2015
Resolution: Received satisfactory class report from DNV-GL stating that PLIBRICO SUPER F AB is suitable repair for incinerator and repairs examined and found in order.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 11 September 2015 Resolved
Fire fighters outfits shall comply with the FSS Code. Personal equipment shall consist of protective clothing of material to protect the skin from heat radiating from the fire. 02 Fire fighting outfits have tears in the protective outer layer. 74SOLAS(2014 Cons)Ch II-2/10.1.1 FSS Code CH 3.2.1.1.1 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2015
Resolution: Received satifactory class report from DNV-GL stating they confirm 4 new fire fighting outfits replaced and found in order.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 15 July 2012 Resolved
0299- Other(Crew)- PSCO observed that there was no records for Ballast Water Management training. Provide copy of training records to USCG. -33CFR151.2035
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 July 2012
Resolved 10 August 2012
Resolution: Received a copy of ballast water management training from the M/V CAPE TALARA satisfying requirement.
Operations/Management › Drills/Instruction › Not Conducted
Issued 15 July 2012 Resolved
0299- Other(Crew) - PSCO observed that there was no training records for the Vessel General Permit. -40CFR122.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 July 2012
Resolved 15 July 2012
Resolution: Defeciency rectified on the spot. Witnessed training of entire crew on VGP.
Deck/Cargo › Inert Gas System › Gas Regulating Valve
Issued 15 July 2012 Resolved
1840- Instrumentation- For inert gas systems of both flue gas type and the inert gas generator type, audible and visual alarms shall be provided to indicate. PSCO observed that the IG Main gas pressure low level alarm is set at 50 mmWG per the IG mainual. -FSS Code 2.4.3.1.8
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 July 2012
Resolved 10 August 2012
Resolution: Received IG instruction manual from Aalborg Industries satisfying requirement.
Documentation › Certificates/Documents › IOPP Certificate
Issued 15 July 2012 Resolved
0150- IOPP- The government of a party to the present convention may, at the request of the administration, cause a ship to be surveyed. PSCO observed that the endorsement for the thru put of the Oily Water Separator was not annotated on the IOPP Form B Supplement. -MARPOL 73/78 Annex I/8
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 July 2012
Resolved 10 August 2012
Resolution: Received a copy of the IOPP Form B Supplement from GL satisfying requirement.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.