← All vessels
MARIA FAITH
MARIA FAITH is a 2008 tank ship. The Coast Guard has recorded 7 inspections since 2015, most recently in May 2026, along with 14 deficiencies — 2 with no resolution recorded — and 3 operational controls.
Records from 2015 to 2026. Most recent: inspection, 22 May 2026.
- Built
- 2008
- Last inspected
- 22 May 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 14 recorded · 2 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9374296 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7A3947
1079502
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1079502
Inspections, by type
…with no type recorded2
…past their stated due date2
Years with a record
4 calendar years (2015–2026)
The 7 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it47125 - Dead Weight, Metric Ton
29266 - Convention (Subpart B), Gross Ton
12026 - Convention (Subpart B), Net Ton
29266 - Convention (Subpart B), Gross Ton
12026 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 7
22 May 2026
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8376511
15 May 2026
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8373826
27 April 2026
PSC A · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8352233
15 May 2024
PSC A · COC-CHEM & TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7912250
15 April 2016
Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual · COE-Offshore
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5854844
11 April 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5851367
1 October 2015
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5732744
Deficiency record · 14
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 22 May 2026
No resolution recorded
In tankers, electrical equipment , cables and wiring shall not be installed in hazardous locations unless it conforms with the standards not inferior to those acceptable to the organization. PSCO found exposed wiring and wastage on high level and overfill alarms/ radar domes electrical conduit manifold on all cargo tanks. Deficiency must be rectified prior to cargo operations.
Solas 11-1/ 45.11
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 22 May 2026
Resolved
The machinery… associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO found disconnected valve actuator, hanging from a towel, on #5 stbd fill valve. Deficiency must be rectified prior to cargo operations.
Solas 11-1/26.1
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 May 2026
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO found fuel leak on the fuel line of the #3 cylinder on the main engine and fuel oil leak from the fuel pump filter assembly in the fuel oil purifier room.
Solas 11-2/ 4.1.1
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 May 2026
Resolved
Ignition sources shall be separated from combustible materials and flammable liquids. PSCO observed the stowage of 55 gallon drums of oil and other materials throughout the cargo block area.
Solas 11-2/ 4.1.5
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 22 May 2026
No resolution recorded
The company should establish procedures to ensure that the ship is maintained in conforming with the provisions of the relevant rules and regulations and additional company requirements . The technical and operational nature of deficiencies 1,2,3,4 provide objective evidence of a failure to implement ISM code. An internal audit, satisfactory to OCMI, must be submitted in 90 days
Solas IX/ 5
ISM 10
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 27 April 2026
Resolved
The company should establish procedures to ensure that the ship is maintained inconformity with the provisions of the relevant rules and regulations and with additional requirements which may be established by the company. The technical and operational nature of deficiencies two, three, four, five, six, seven, and eight provide objective evidence of a serious failure of implementation of the ISM code. An external audit report satisfactory to the OCMI must be submitted prior to clearance of this deficiency.
74SOLAS (20) IX/ 3.1
ISM Code 10.1
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 April 2026
Resolved
Sufficient foam concentration shall be supplied to ensure at least 30 minutes of foam generation when using the highest of the solution rates.
PSCO observed foam quantity of 7.2 m3 when system requires 7.5 m3 for necessary amount.
74SOLAS(20) VII/10.1
IBC 11.3.6
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 27 April 2026
Resolved
Such monitoring equipment shall also provide an alarm facility which is activated by detection of over pressure or under pressure conditions within a tank.
Crew had disabled audible alarm for pressure alarms by taping over speaker, redering alarms inaudible in CCR.
74SOLAS(20) VII/ 10.1
IBC 8.3.3
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 27 April 2026
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
PSCO observed 03 category A fire doors that shall be self-closing that did not self-close and numerous hold backs were present on self-closing doors. 01 fire door from galley to passage way, 01 fire door from galley to crew mess, and 01 fire door from engine room to crew locker room not self-closing.
74SOLAS (20) I/11a
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 27 April 2026
Resolved
Independent cargo tanks shall be electrically bonded to the hull. All gasketed cargo-pipe joints and hose connections shall be electrically bonded. PSCO observed numerous bonding wires twisted, missing and not connected throughout the cargo piping on deck.
74SOLAS(20) VII/ 10.1
IBC 10.2
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 April 2026
Resolved
Life buoys shall be stowed as to be capable of being rapidly cast loose.
PSCO observed life buoys on bridge wing not stowed for rapid release. Connection to smoke/light signal interfered with release.
74SOLAS(20) III/ 7.1.1.2
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 27 April 2026
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
74SOLAS(20) I/11a
PSCO observed number 35 ballast water tank vent on deck had a hole rusted in the top that had been taped and painted over.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 April 2026
Resolved
Emergency towing arrangements at both ends shall be of adequate strength taking into account the size and deadweight of the ship, and the expected forces during bad weather conditions. The design and construction and prototype testing of emergency towing arrangements shall be approved by the Administration.
The PSCO observed the aft emergency towing light to be extinguished.
74SOLAS(20)II-1/3.1.1.2.2
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 27 April 2026
Resolved
Each vessel vapor connection flange face must have a permanent stud projecting outward that has a 12.7 millimeter (0.5 inch) diameter and is at least 25.4 millimeters (1 inch) long.
PSCO observed the bolt on flange face to be deteriorated and not correct size.
46CFR39.2001(j)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National