TALISMAN is a 2000 freight ship. The Coast Guard has recorded 35 inspections since 2016, most recently in May 2026, along with 16 deficiencies and 5 operational controls.

Records from 2016 to 2026. Most recent: inspection, 20 May 2026.

Built
2000
Last inspected
20 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 May 2026
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9191319
Flag
NORWAY
Maury page id
psix-10808

Documentation record

Tonnage as PSIX records it39423 - Dead Weight, Metric Ton
64299 - Displacement, Metric Ton
67140 - Convention (Subpart B), Gross Ton
23674 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

TAKEUCHI SEA Tank Barge · MISLE 910950 · 28 October 2018 · activity 6575893

Inspection history · 35

20 May 2026 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8376970
7 February 2026 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8307487
16 September 2025 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8230415
2 April 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8104170
1 April 2025 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8102979
7 February 2025 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8076002
7 February 2025 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8076504
5 February 2025 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8075411
13 January 2025 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8058813
16 May 2024 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7913321
11 April 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7893630
25 January 2024 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7845961
13 January 2024 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7849030
17 April 2023 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7670125
13 April 2023 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7666573
19 October 2022 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7579494
7 April 2022 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7426348
7 October 2021 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7328168
24 April 2021 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7178828
28 December 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7116958
23 September 2020 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7063668
18 March 2020 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6928473
11 February 2020 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6904027
11 February 2020 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6907113
24 September 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6814267
2 May 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6678977
11 January 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6606133
30 October 2018 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6572605
28 October 2018 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6575893
19 May 2018 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6414814
2 May 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6399247
2 August 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6228222
16 December 2016 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6057986
2 December 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6051376
17 April 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5853227

Deficiency record · 16

01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 7 February 2025 Resolved
OIL RESIDUE MAY BE DISPOSED OF DIRECTLEY FROM RESIDUE TANKS TO RECEPETION FACILITIES THROUGH THE STANDARD DISCHARGE CONNECTION REFERRED TO IN REGULATION 13, OR TO ANY OF THE APPROVED MEANS TO DISPOSE OF OI RESIDUE,... OR ACCEPATABLE MEANS CHICH SHALL BE ANNOTED IN ITEM 3.2 OF THE SUPPLEMENT TO IOPP CERTIFICATE FORM A. PSCO OBSERVED ENTERIES IN ORB FOR EVAPORTATION OF WATER FROM THE WASTE OIL EVAPORATION TANK THAT IS NOT INDICATED ON THE IOPP SUPPLEMENT AS AN APPROVED OTHER ACCEPTABLE MEANS. MARPOL73/78 Annex I/12.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 March 2025
Resolution: DNV do not describe 'natural' evaporation from sludge tank(s) under item 3.2.3 in IOPP Supplement, as actually heating of sludge tanks are mandatory in MARPOL Annex I. In other words DNV do not consider such evaporation as "Other acceptable means".
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 February 2025 Resolved
THE ARRANGEMENTS FOR THE STORAGE, DISTRIBUTION AND UTILIZATION OF OIL USED IN PRESSURE LUBRICATION SYSTEMS SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BOARD. PSCO OBSERVED LEAKING FROM THE M/E L/O HEAT EXCHANGER. 74 SOLAS(01) II-2/15.3
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 March 2025
Resolution: Re-tightening of the cooler's assembly bolts, declared as carried-out by the on-board crew-member
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 7 February 2025 Resolved
AFTER ANY SURVEY OF THE SHIP UNDER PARAGRAPH 1 OF THIS REGULATION HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURE,EQUIPMENT SYSTEMS, FITTINGS, ARRANGEMENTS, OR MATERIAL COVERED BY THE SURVEY, WITHOUT SANCTION OF THE ADMINISTRATION, EXCEPT THE DIRECT REPLACEMENT OF SUCH EQUIPMENT AND FITTINGS. PSCO OBSERVED A PINHOLE LEAK IN PIPING FROM BILGE HOLDING TANK TO OWS. CREW CONDUCTED TEMP REAPAIRS. MARPOL73/78 ANNEX I/6.4.2 MARPOL I/6.4.2 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 March 2025
Resolution: Renewal of the piholed pipe-section, declared as completed by the on-board crew-members, is recorded as the permanent rectification of defective arrangements
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 7 April 2022 Resolved
11112 - Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed hydraulic power pack unit piping for the lifeboat leaking at the gauge fittings. 74SOLAS(20)III/20.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 April 2022
Resolution: Vessel personnel replaced leaking gauge and tightened all fittings. PSCO observed no further leaks upon repair.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 April 2021 Resolved
IW A SHIP IN WHICH FUEL OIL IS USED, ARRANGEMENTS FOR THE DISTRIBUTION OF THE FUEL OIL SHALL BE SUCH TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BOARD. PSCO WITNESSED OIL SOAKED RAGS UNDER LEAKS AND WET OIL SPOTS ON MULTIPLE AUX. ENGINES AND M/E CYLYNDER #1.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2021
Resolved 24 April 2021
Resolution: Recieved report from classification society
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 24 September 2019 Resolved
MARPOL 73/78 I/6.4.1 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present convention to ensure that the ship in all respects will remain fit to proceed to sea without presenting an unreasonable threat of harm to the marine environment. Three pinhole leaks were discovered on the OWS system; one on the inlet pipe for the OWS bilge water heater and one each on two of the three OWS cylinders. (40ac)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 October 2019
Resolution: Vessel provided [name withheld] attesting to the repairs of the pinhole leaks on the OWS system. See documnets.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 30 October 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision fot eh present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel involved in collision during transit/turning within the Savannah River. Provide evidence that affected hull and welds are structurally sound.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 1 November 2018
Resolved 30 October 2018
Resolution: Received class report attesting to structural integrity of affected portion of hull.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 2 May 2018 Resolved
The means of control of any fixed gas fire-extinguishing system shall be readily accessible and simple to operate and shall be grouped together in an few locations as possible at positions not likely to be cut off by fire in a protected space. At each location there shall be clear instructions relating to the operation of the system having reard to the safety of personnel. The manual isolation valve for the low pressure CO2 system was found in the closed position. Crew would not by able to engage CO2 for protected spaces from the remote location. The wrench to open the manual isolation valve was not present in the local space and took approximately one minute to retrieve. Each location did not have clear instructions that included the opening of the manual isolation valve.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 2 May 2018
Resolved 3 May 2018
Resolution: Vessel provided satisfactory Class reports attesting to the operational status of the isolation valve.
Engineering › Steering Gear System › Rudder
Issued 2 May 2018 Resolved
The main steering gear shall be capable of putting the rudder over from 35degrees on one side to 35 degrees on the other side with the ship at its deepest seagoing draught and running ahead at maximum ahead service speed and, under the same conditions from 35 on either side to 30 degrees on the other side in not more than 28 seconds. Emergency steering unit does not put rudder over to 35 degrees port (vessel does not have full range of motion on port side)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2018
Resolved 3 May 2018
Resolution: Vessel provided satisfactory Class reports attesting to the operational status of the steering gear rudder.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 2 May 2018 Resolved
Every oil fuel pipe which, if damaged would allow oil to escape from a storage, settling or daily service tank situated above the double bottom shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occuring in the space in which such tanks are situated. Oil Fuel tank valve for the emergency generator is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2018
Resolved 3 May 2018
Resolution: Vessel provided satisfactory Class reports attesting to the operational status of the quick closing valve for the emergency generator.
Documentation › Certificates/Documents › IOPP Certificate
Issued 2 May 2018 Resolved
After any survey of the ship has been completed, no change shall be made in the structure, equipment, systems, fittings, arrangements or materials covered by the survey. IOPP certificate certifies the separating/filtering equipment in accordance with MPEC.60 (33). Vessel has a MEPC. 107(48) system installed onboard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2018
Resolved 3 May 2018
Resolution: Vessel provided satisfactory Class reports attesting to issuance of Interim IOPP and verified the vessel is certificated for the correct OWS unit onboard.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 2 May 2018 Resolved
Doors fitted in boudary bulkheads of machinery spaces of Catagory A shall be reasonably gas tight and self closing. Door from engine room to port side bunkering station was not self closing.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 17 May 2018
Resolved 3 May 2018
Resolution: Vessel provided satisfactory Class reports attesting to the operational status of the self-closing door to the bunkering station.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 2 December 2016 Resolved
(40ac) 74SOLAS (2001 cons) II-2/9.2.3.3.1- The minimum fire integrity of bulkheads and decks shall be as prescribed in tables 9.5 and 9.6- Ventilation ducting installed compromising the integrity of class 'A' Boundary.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 December 2016
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 2 December 2016 Resolved
(40ac)74SOLAS (2001 cons) II-2/9.2.3.3.1- The mimium fire integrity of bulkheads and decks shall be as prescribed in tables 9.5 and9.6- Wiring throughout the ship installed compromising the integrity of class 'A' boundries.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 December 2016
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 2 December 2016 Resolved
(40ac)74SOLAS (2001 cons) II-2/10.4.1.1.1 FSS CODE: 2.1.1.3- A fixed gas Fire-Estinguishing system complyi9ng with the provisions of the fire safety systems code. Means shall be provided for the crew to safely check the quanitiy of the fire-estinguishing medium in the containers. [name withheld] discovered both sight glasses for both CO2 tanks frozen in place.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 December 2016
Fire Fighting › Ventilation Systems › Ducts
Issued 2 December 2016 Resolved
(40ac)74SOLAS(2001 cons) CH1/11(a)- The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. - PSC Examiners discovered unapproved installation of dryer ducting directly connected to accomodation space vent system
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 December 2016

Ownership record