MAURY USCG vessel records Sign in
← All vessels

RUDOLF

RUDOLF is a 2010 public freight. The Coast Guard has recorded 19 inspections since 2014, most recently in July 2026, along with 8 deficiencies and 1 operational control.

Records from 2014 to 2026. Most recent: inspection, 21 July 2026.

Built
2010
Last inspected
21 July 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9535591 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1080990
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-1080990

Inspections, by type

…with no type recorded5
Years with a record 6 calendar years (2014–2026)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it10872 - Dead Weight, Metric Ton
15102 - Displacement, Metric Ton
8059 - Convention (Subpart B), Gross Ton
3909 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 19

21 July 2026 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8443416
26 January 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6344241
5 December 2017 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6318491
26 November 2017 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6310216
21 November 2017 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6310661
9 August 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6236058
23 April 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6132262
7 April 2017 ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6119555
7 September 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam · COE-Dockside
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5990186
5 August 2016 COE-Dockside
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5960370
27 June 2016 In-Service Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5920924
1 September 2015 Deficiency Check · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5232402
19 August 2015 Administrative Inspection · ISPS II Exam · Enhanced Seaway Inspection (Massena only) · Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5218648
29 May 2014 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4873458
22 May 2014 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4865438
16 May 2014 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4859928
15 May 2014 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4860048
15 May 2014 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4861209
14 May 2014 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4853322

Deficiency record · 8

Lifesaving › Launching Appliances › Davit
Issued 26 November 2017 Resolved
(74SALAS)14 CH.III/16.2 EACH LIFE BOAT SHALL BE PROVIDED WITH AN APPLIANCE WHICH IS CAPABLE OF LAUNCHING AND RECOVERING THE LIFE BOAT. THE DAVIT IS UNABLE TO RECOVER THE LIFEBOAT.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 28 December 2017
Resolved 26 January 2018
Resolution: SEC HOU-GAL received class report from BV attesting to proper operation of the resuce boat recovery gear, satisfying the requirement.
Engineering › Steering Gear System › Actuator
Issued 27 June 2016 Resolved
All the steering gear components and the rudder stock shall be of sound and reliable construction to the satisfaction of the administration. Steering gear not working properly. SOLAS 2014 CHII-1 Reg. 29.2.1. (17ac).
Due 27 June 2016
Resolved 3 July 2016
Resolution: The manufacture has replaced the over-ride steering module that was causing a fault with the follow-up and non-follow up control from the bridge. Class and PSC team conducted a satisfactory steering gear test.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 2 September 2015 Resolved
2535 - Development of plans for shipboard ops - The company should establish procedures, plans, and instructions for key shipboard operations concerning the Safety of the personnel, ship and protection of the environment. Vessel cannot provide procedure for maintenance of fuel oil purifiers after change over to low Sulfur fuel. 74 Solas (14) CH. IX/3.1 ISM Code 7 (17a)
Action required: 705 - Other - as specified
Resolved 3 September 2015
Resolution: Company provided and implemented procedures for the maintenance of Fuel Oil Purifies when using Low Sulfur Fuel.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 2 September 2015 Resolved
0710 - Fire prevention - To prevent the ignition of combustible materials of flammable liquids means shall be provided to control leaks of flammable liquids. There are several leaks throughout the main engine, Flexible hoses have been installed off the main engine and slop tank pipe on stbd side. Oil from these hoses is being contained in plastic containers. 74 Solas (14) Ch. II-2/4.1.1 (17a)
Action required: 705 - Other - as specified
Resolved 3 September 2015
Resolution: Hoses from Main Engine and hoses connected to slop tank have been removed. Oil being contained in plastic containers have been disposed of and removed from engine room space.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 2 September 2015 Resolved
0710 - Fire Prevention - To prevent the ignition of combustible materials or flammable liquids, ignition sources shall be separated from combustible materials and flammable liquids. A pipe of approx. 1" diameter with oil inside, a pump with oil residue on connecting points and plastic containers were stored next to a heated lube oil pipe. 74 Solas (14) CH. II-2/4.1.5
Action required: 705 - Other - as specified
Resolved 3 September 2015
Resolution: The pipe and pump were removed from the stowed space that had the heated lube oil pipe.
Engineering › Steering Gear System › Actuator
Issued 15 May 2014 Resolved
The vessel experienced a steering loss while in the Mississippi River.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 May 2014
Resolved 16 May 2014
Resolution: Received, reviewed and accepted class report from [name withheld] stating the steering gear is operational, tested and found satisfactory. According to Lloyds Register it was incidental operator error.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 May 2014 Resolved
1740- Pollution Prevention- C/E and crew were unfamiliar with procedures to recall OWS operation history. - MARPOL 74/78 Annex I/11
Action required: 705 - Other - as specified
Due 28 May 2014
Resolved 29 May 2014
Resolution: SEC NOLA PSC/Arrivals Branch received proper documentation satisfying the requirement.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 14 May 2014 Resolved
0725 - Remote Operating - PSCO observed lock boxes in place in place for both CO2 room and the engine room CO2 release space, however no key or break glass were in place. - 74 SOLAS (04 Cons) II-2/10
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 May 2014
Resolved 29 May 2014
Resolution: SEC NOLA PSC/Arrivals Branch received proper documentation satisfying the requirement.

Ownership record