MAURY USCG vessel records
← All vessels

JERSEY

JERSEY is a 2010 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2016, most recently in August 2026, along with 15 deficiencies and 2 casualty investigations in 2014.

Records from 2014 to 2026. Most recent: inspection, 13 August 2026.

Built
2010
Last inspected
13 August 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 August 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDF7218
1081931
Flag
UNITED STATES
Maury page id
psix-1081931

Documentation record

Registered dimensions (L × B × D)69.0 ft × 25.7 ft × 9.6 ft
Registered tonnagegross 76 / net 52
ITC dimensions (L × B × D)69.0 ft × 25.7 ft × 9.6 ft
ITC tonnageNot recorded
BuilderALL AMERICAN MARINE INC · BELLINGHAM, WA, UNITED STATES · built 2010
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 27 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it76 - Regulatory (Subpart C or D), Gross Ton
52 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

13 August 2026 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8463120
3 March 2026 Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8319172
30 October 2025 Internal Structural Exam · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8260962
30 January 2025 Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8071848
28 August 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7990864
27 June 2024 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7943779
12 March 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7877959
15 November 2023 Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7824624
7 October 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7806033
28 August 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7780576
17 November 2022 Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7585267
3 August 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7528924
14 December 2021 Administrative Inspection · Hull Examination · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7369705
1 December 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7360406
11 March 2021 In-Service Inspection · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7154585
18 November 2020 Internal Structural Exam · COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7094792
31 August 2020 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7046485
19 November 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6858220
20 February 2019 Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6629122
23 July 2018 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6487987
20 November 2017 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6309821
14 November 2016 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6040385
25 July 2016 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5952164

Deficiency record · 15

02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 3 March 2026 Resolved
The owner or managing operator shall notify the cognizant OCMI as far in advance as possible whenever a vessel is to be hauled out to undergo repairs or alterations affecting the safety of the vessel. Vessel experienced hull side shell damage below the water line of the fore peak spaces. Provide repair plan for crop and renew prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 March 2026
Resolution: Observed proper repairs and satisfactory NDT weld testing.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 17 November 2025 Resolved
An inflatable buoyant apparatus must be serviced at a facility specifically approved by the Commandant for the particular brand, and in accordance with servicing procedures. Vessel's 02 IBAs were passed due on scheduled servicing by one month. Vessel is restricted to routes within 01 mile from shore. 46 CFR 185.730 46 CFR 180.200(c)
Action required: 705 - Other - as specified
Resolved 20 August 2026
Resolution: Restricted on routes 1 mile from shore. - attended the vessel on 20AUG26 noticed uncleared def from 17NOV26. MI verified IBA service record with next service due MAR2027.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 January 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. MI identified corroded junction box in port laz. Replace within 14 days. 46 CFR 183.200(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 March 2025
Resolution: Received photos of replaced junction box.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 August 2023 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Vessel operator notified the duty marine inspector of an overheating port engine while underway. Vessel was able to safely moor to its home pier. Submit casualty analysis and corrective action report to the local OCMI after repairs have been made.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 August 2023
Resolution: Observed under pressure, all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 November 2020 Resolved
46CFR177.500(m)Ladders and similar means provided to aid escape, must be suitable for use in emergency conditions, of rigid in position, unless they can be folded, yet brought into immediate service in an emergency. Ladder in port lazarette has a broken leg.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2020
Resolved 6 January 2021
Resolution: Received picture of broken ladder welded.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 November 2019 Resolved
Remove dead end wires in STBD A/C space. 46CFR183.200
Action required: 10 - Deficiency Rectified
Due 19 November 2019
Resolved 19 November 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 November 2019 Resolved
Replace cable from switch to fire pump due to open splices and deteriorated wires. 46CFR183.200
Action required: 10 - Deficiency Rectified
Due 19 November 2019
Resolved 19 November 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 19 November 2019 Resolved
Attach hour meter to STBD MDE.
Action required: 10 - Deficiency Rectified
Due 19 November 2019
Resolved 19 November 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 November 2019 Resolved
Find and fix exhaust leak in LAZ. 46CFR182.430
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2019
Resolved 18 December 2019
Resolution: found leaking stainless steel bellow and replaced with new one. Tested sat and wrapped with lagging.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 19 November 2019 Resolved
Crew failed MOB drill. Replaced the crew with "normal crew" and passed drill. Further info in narrative. 46CFR185.420
Action required: 10 - Deficiency Rectified
Due 19 November 2019
Resolved 19 November 2019
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 20 February 2019 Resolved
IBA's shall be stored in a float-free arrangement. The port side IBA's hydrostatic release expired in Nov. 2017. Replace Hydrostatic release with a non-expired one. 46CFR180.130(a)(2)
Action required: 705 - Other - as specified
Due 27 February 2019
Resolved 27 February 2019
Resolution: Photo of the replacement Hydrostatic release and its installation were provided to [name withheld].
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 20 February 2019 Resolved
IBA's shall be stored in a float-free arrangement. The port and starboard side IBA's were ratchet strapped to the cradle. Ratchet strap was removed prior to completion of inspection and MI explained the severity of the deficiency to the vessel rep and discussed methods to prevent future non-compliance. 46CFR180.130(a)(2)
Action required: 10 - Deficiency Rectified
Resolved 20 February 2019
Communications › Alarms/Indicators › Bilge Alarm
Issued 26 February 2018 Resolved
Prove visual and audible alarm of starboard lazarette high water alarm.
Action required: 705 - Other - as specified
Due 5 March 2018
Resolved 27 February 2018
Resolution: Vessel repaired high bilge alarm.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Exhaust Manifold
Issued 26 February 2018 Resolved
Exhaust leak in starboard lazarette space.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 February 2018
Resolution: Vessel repaired exhaust leak in starboard lazarette.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 20 November 2017 Resolved
Prove annual servicing of 02 IBA's. Vessel is restricted to no more than 1 mile from shore.
Action required: 705 - Other - as specified
Resolved 4 April 2018
Resolution: Verified annual servicing of (02) IBAs.

Casualty record · 2

30 January 2014Routine · role: Involved in a Marine Casualty · activity 4795626
5 March 2014Routine · role: Involved in a Marine Casualty · activity 4811237
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.