MAURY USCG vessel records
← All vessels

SIR-BRI

SIR-BRI is a 2010 towing vessel. The Coast Guard has recorded 11 inspections since 2012, most recently in June 2026, along with 5 deficiencies.

Records from 2012 to 2026. Most recent: inspection, 2 June 2026.

Built
2010
Last inspected
2 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDG5149
1082018
Flag
UNITED STATES
Maury page id
psix-1082018

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspections, by type

Years with a record 10 calendar years (2012–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)62.0 ft × 26.0 ft × 6.0 ft
Registered tonnagegross 64 / net 51
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLARRY T CALDWELL · CANTON, MO, UNITED STATES · built 2010
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 September 2025 · expires 31 October 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it64 - Simplified, Gross Ton
51 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 11

2 June 2026 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 8390120
10 June 2025 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 8157113
10 June 2024 Drydock Exam · COI Inspection · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7921462
23 June 2023 Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7721591
25 May 2022 Administrative Inspection · Periodic Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7459006
1 July 2021 Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7247950
4 May 2020 Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6948495
28 April 2020 Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6945028
19 June 2019 DAPI Audit · MTSA Verification · Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6716740
2 August 2016 Deficiency Check · Industry Initiated Exam · Administration · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5962372
4 January 2012 Industry Initiated Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4217818

Deficiency record · 5

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 June 2020 Resolved
Cap or seal the fuel return line vent terminating in the engine room. Integral fuel tank vents are required to only vent to the weather deck.
Action required: 10 - Deficiency Rectified
Resolved 10 June 2020
Resolution: Fuel return line vent capped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 June 2019 Resolved
Ensure the flexible fuel hose on the generators meet 46CFR143.265(d). The current hose (SAE 30R7) is not double lined nor wire re-enforced.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 30 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 June 2019 Resolved
Ensure the air compressor relief valve is properly tested as per table 46CFR143.245(b).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 30 July 2019
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 19 June 2019 Resolved
Verify the emergency fuel shut off valve operates freely. The valve operates but is currently hard to turn.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 30 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 June 2019 Resolved
Ensure the type I PFD’s in the electrical room are properly stored. PFD’s are currently stacked inside the cardboard shipping box. The PFDs are properly labeled and outfitted.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 30 July 2019

Ownership record