Records in 2018. Most recent: inspection, 26 November 2018.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 November 2018
Resolved
The machinery, boilers, and other pressure vessels associated piping systems and fitting shall be of a design and construction adequate for the service for which they are intended. Emergency fire pump's priming pump motor is out of operation and can no longer prime the emergency fire pump. 14SOLAS CH. II-1/26.1 60ABC
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2018
Resolution: Priming pump was repaired and operating at full capacity. Operation observed by USCG and Class, cleared by Flag.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 November 2018
Resolved
Fire protection systems and fire fighting systems and appliances shall be maintained and ready for use. Multiple hose connections in the CO2 space are twisted and bent. Calling into the question the operational ability of the fire fighting system. 14SOLAS CH. II-2/14.1 60ABC
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 December 2018
Resolution: CO2 lines were re routed by technician. Repairs approved by class. Cleared by USCG and Flag.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 26 November 2018
Resolved
As far as is reasonable and practicable, rescue boats other than lifeboats which are also rescue boats, shall be launched each month with their assigned crew aboard and maneuvered in the water. In all cases this requirement shall be complied with at least once every three months. Vessel's crew has not launched the vessel's rescue boat since July, over a month beyond the rescue boat's scheduled inspection. 14SOLAS CH. III/19.3.3.6 17ABC
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 December 2018
Resolution: Ship performed rescue boat drill and provided documentaion of drill records.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 26 November 2018
Resolved
Ships shall be provided with arrangements. Equipment and fittings of sufficient safe working load to enable the safe conduct of all towing and mooring operations associated with the normal operation of the ship. Vessel is using 3 spliced mooring lines in addition to several lines which are fraying. 14SOLAS CH. II-1/3-8.2 17ABC
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 3 December 2018
Resolved 3 December 2018
Resolution: New lines were purchased by vessel and are onboard.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 26 November 2018
Resolved
The function of fixed firefighting detection and fire alarm systems shall be periodically tested to the satisfaction of the Administration. Vessel does not have appropriate means of equipment producing hot air at appropriate temperature to which the detector is designed to respond. Vessel's crew cannot provide evidence of a required means of testing the flame detectors.
14SOLAS CH. II-2/3.2 17ABC
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 3 December 2018
Resolved 3 December 2018
Resolution: New approved equipment was placed onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Laundry
Issued 26 November 2018
Resolved
Crew accomodation shall be provided with sufficient drainage. Crews drying room within laundry room found with excessive standing water. Crew later removed blockage.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 November 2018
Resolved 26 November 2018
Resolution: Room was drained, and blockage removed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 November 2018
Resolved
Vessel owner or operator must ensure that they maintain a copy of VRP. Vessel did not have copy of VRP on board. Copy provided by company.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 November 2018
Resolved 26 November 2018