MAURY USCG vessel records
← All vessels

NICOLAOS

NICOLAOS is a 2010 tank ship. The Coast Guard has recorded 7 inspections since 2016, most recently in May 2024, along with 2 deficiencies and 1 operational control.

Records from 2016 to 2024. Most recent: operational control imposed, 28 May 2024.

Built
2010
Last inspected
28 May 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9429297
1085505
Flag
GREECE
Maury page id
psix-1085505

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded2
Years with a record 3 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it54305 - Convention (Subpart B), Net Ton
164758 - Dead Weight, Metric Ton
84735 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 7

28 May 2024 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7922043
11 April 2024 PSC B · COC-TVE Renew
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7893524
11 April 2018 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6384144
5 April 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6385920
22 September 2016 ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6004384
17 May 2016 ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5879462
17 May 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5879645

Deficiency record · 2

Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 11 April 2018 Resolved
0720 Fire protection systems and fire fighting systems and appliances shall be maintained ready for use. PSCO discovered a CO2 actuation line disconnected. If the system were activated, CO2 would be discharged into the CO2 room and the Engine Room would be left unprotected.
Action required: 10 - Deficiency Rectified
Resolved 11 April 2018
Resolution: Line was reconnected and tightend
Documentation › Certificates/Documents › IOPP Certificate
Issued 11 April 2018 Resolved
The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present convention to ensure that the ship in all respects will remain fit to proceed to sea without presenting an unreasonable threat or harm to the enviroment. On 09Mar18, from 0953-1207, the vessel discharged 15m3 of bilge water through the OWS. A discharge of this quantity in this time averages to 6.72m3/hour. The IOPP Form B states OWS capacity of 5m3/hour
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 April 2018
Resolution: Received clss report attesting to the OWS throughput

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.