REBECCA is a freight ship. The Coast Guard has recorded 9 inspections since 2017, most recently in May 2025, along with 5 deficiencies and 3 operational controls, 2 with no removal date recorded.
Records from 2017 to 2025. Most recent: operational control imposed, 10 May 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it1903 - Simplified, Net Ton 3442 - Convention (Subpart B), Gross Ton 5622 - Dead Weight, Ton 7281 - Displacement, Ton 1903 - Convention (Subpart B), Net Ton 3442 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
14 - Pollution Prevention › 148 - Ballast Water › Ballast water report
Issued 5 May 2025Resolved
The master, owner, operator, agent, or person in charge of a vessel subject to this subpart and this section must submit a ballast water report to the National Ballast Information Clearinghouse (NBIC) by electronic ballast water report format using methods specified at NBIC's Web site. Vessel failed to properly submit ballast report.
33CFR151.2060 (b)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 6 May 2025
Resolution: CG inspector provided guidance on proper submission and witnessed succesful submission.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 July 2019Resolved
A main source of electrical power of sufficient capacity to supply all those services mentioned in regulation 40.1.1 shall be provided. This main source of electrical power shall consist of at least two generating sets. Belt on main generator was found to be wasted, requiring vessel to rely on emergency generator. Repairs made by crew must be verified by class. 74SOLAS(04) II-1/41.1.1 Action Code: 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 December 2021
Resolution: recieved class report to clear deficiency
Electrical › Electrical Distribution System (service) › Switchboard
Issued 3 July 2017Resolved
MAIN AND EMERGENCY SWITCHBOARDS SHALL BE SO ARRNAGED AS TO GIVE EASY ACCESS AS MAY NEEDED TO APPARATUS AND EQUIPMENT WITHOUT DANGER TO PERSONNEL. THE SIDES AND REAR, WHERE NECESSARY, THE FRONT THE FRONT OF SWITCHBOARDS SHALL BESUITABLY GUARDED.
PSCO OBSERVED FRONT PANELS EITH REMOVED OR PROPPED OPEN ON SWITCHBOARDS LOCATED IN THE BRIDGE AND ENGINEROOM. POSING AS A SHOCK HAZRD, THIS IS DUE TO...
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 August 2017
Resolved 17 July 2017
Resolution: Received Class Report attesting to the correction of this deficiency.
Accommodation/Occupational Safety › Ventilation › General
Issued 3 July 2017Resolved
THE EQUIPMENT OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THE SHIP WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. A/C IS INOPERABLE, CAUSING CREW TO VENTILATE ELECTRICAL EQUIPMENT IN AN UNSAFE MANNER
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2017
Resolved 17 July 2017
Resolution: Received Class Report attesting to the correction of this deficiency.
NAVIGATIONAL CHARTS AND NAUTICAL PUBLICATIONS, SUCH AS SAILING DIRECTIONS, LISTS OF LIGHTS, NOTICE TO MARINERS, TIDE TABLES AND ALL OTHER PUBLICATIONS NECESSARY FOR THE VOYAGE SHALL BE ADEQUATE AND UP TO DATE.
SHIP IS MISSING INTERNATIONAL NAV RULES.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 August 2017
Resolved 6 July 2017
Resolution: VESSEL HAS RECIEVED BOTH A HARD COPY AND A DIGITAL COPY OF THE REQUIRED PUBLICATION.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.