Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it19231 - Convention (Subpart B), Net Ton 67681 - Displacement, Metric Ton 57022 - Dead Weight, Metric Ton 33044 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 6
26 June 2025Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8168320
21 May 2025PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8136912
29 March 2022Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7420669
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 May 2025Resolved
Except as permitted by the administration in exceptional circumstances, all metal sheaths and armor of cables shall be electrically continuous and shall be earthed. PSCO observed over 20 wasted bonding straps. 74 SOLAS II-I/45.5.1, Rectify deficiency within 14 days, Code 16ac.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 23 June 2025
Resolution: PSC NOLA received a proper documentation from NIPPON KAIJI KYOKAI satisfying the requirement.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 May 2025Resolved
Electrical installations shall be such that the safety of crew and ship from electrical hazards will be ensured. PSCO observed hole in first electrical conduit box on port side. 74 SOLAS II-I/40.1.3,Rectify deficiency within 14 days, Code 16ac.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 23 June 2025
Resolution: PSC NOLA received a class report from NIPPON KAIJI KYOKAI satisfying the requirement.
The master, owner, operator, agent, or person in charge of a vessel equipped with ballast tanks that operates in the waters of the United States must employ one of the authorized ballast water management methods listed in 33 CFR 151.2025(a). Vessel’s ballast water management system is inoperable. Vessel has been granted an extraordinary circumstance to employ the ballast water management method listed in 33 CFR 151.2025(a)(3) to conduct cargo operations while in the Sector New Orleans COTP Zone. In accordance with 33 CFR 151.2040(b)(3), the vessel must discharge only that amount of ballast water operationally necessary to ensure the safety and stability of the vessel for cargo operations.
33 CFR 151.2025(a)
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 May 2025
Resolution: Received class report attesting to satisfactory repairs.