CARIBBEAN FANTASY

CARIBBEAN FANTASY is a 1989 passenger vessel (inspected). The Coast Guard has recorded 7 inspections in 2016, along with 12 deficiencies — 4 with no resolution recorded — and 5 operational controls, 1 with no removal date recorded.

Records in 2016. Most recent: operational control imposed, 10 November 2016.

Built
1989
Last inspected
10 November 2016
Documentation
Not in the documentation file of 10 August 2026
Controls
1 with no removal date recorded

Identity

8814263
1085710
Flag
PANAMA
Maury page id
psix-1085710

Inspections, by type

…with no type recorded2
…past their stated due date4
Years with a record 1 calendar year (2016)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it10092 - Convention (Subpart B), Net Ton
16775 - Displacement, Ton
6219 - Dead Weight, Ton
28112 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.

Inspection history · 7

10 November 2016 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6039189
6 September 2016 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5993588
17 August 2016 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5977513
17 August 2016 NPV Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5980256
9 August 2016 ISPS II Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5963390
11 March 2016 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5831390
3 February 2016 ISPS II Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5799679

Deficiency record · 12

Documentation › Certificates/Documents › Passenger Ship Safety Certificate
Issued 17 August 2016 No resolution recorded
Vessel experienced a fire in the engine room leading to an abandon ship. Life saving appliances, navigation equipment, firefighting equipment and fire suppression systems, are no longer in compliance with issued certificates. Administration and/or RSO should provide current validity status of all statutory certificates. 74Solas(97)I/19(b) 74Solas(97)I/11(c)
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 August 2016 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 10 August 2016 No resolution recorded
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO found in Cabin 31 an duplex 120 volt electrical outlet hanging by the electrical cable (not installed in an electrical box) above a crewmembers rack and a 120 volt duplex outlet improperly used for 220 volt service. 74 SOLAS (97) II-1/45.1.3 16ac
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 August 2016 — due date passed with no resolution recorded
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 9 August 2016 Resolved
Fire doors shall be self-closing and be capable of closing with an angle inclination of up to 3.5 opposing closure. A self-closing door next to #7 House Keeping Locker stays open. 74 SOLAS (97) II-2/30.4.1, 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 August 2016
Resolved 9 August 2016
Resolution: Cleared while onboard.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 9 August 2016 Resolved
Fire door shall be self-closing and be capable of closing with an angel of inclination of up to 3.5 opposing closured. PSCO found fire doors #610 and #612 not closing and out of sequence. 74 SOLAS (97) II-2/30.4.1, 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 August 2016
Resolved 9 August 2016
Resolution: Cleared prior to departing vessel.
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 9 August 2016 Resolved
Any required fire detection and alarm system shall be capable of immediate operation at all times and no action by the crew shall be necessary to set it in operation. PSCO found smoke detector and sprinkler head hanging below the overhead at the outside of the SPA. 74 SOLAS (97) II-2/12.1.1, 10c
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 August 2016
Resolved 9 August 2016
Resolution: Cleared prior to departing vessel.
Fire Fighting › Structural - A Class Divisions › Cargo Spaces (moderate fire risk)
Issued 9 August 2016 No resolution recorded
Boundaries of bulkheads and decks of special catagory spaces shall be insulated to A-60. Frame 22, Deck B middle deck overhead insulation is missing. 74 SOLAS (97) II-2/37.1.2.1, 16ac
Condition: Improper/Lack of Maintenance
Due 23 August 2016 — due date passed with no resolution recorded
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 9 August 2016 No resolution recorded
Ventilation ducts serving RO-RO cargo spaces capable of being effectively sealed shall be separated from each cargo space. PSCO found the Aft, 017B Garage, two dampers not closing. 74 SOLAS (97) II-2/53.2.3.1., 16ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 August 2016 — due date passed with no resolution recorded
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 9 August 2016 Resolved
A closed RO-RO space not capable of being sealed shall be fitted with an approved fixed pressure water spray system for manual operation which shall protect all parts of any deck and vehicle platform in such space. PSCO found a total of 21 drencher nozzles on C Deck Zone 2 and Zone 3 missing. 74 SOLAS (97) II-2/54.2.9, 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 August 2016
Resolved 9 August 2016
Resolution: Cleared prior to departing vessel. Vessel had new nozzles onboard.
Lifesaving › Lifeboat Equipment › Tools (engine)
Issued 3 February 2016 Resolved
Lifeboat equipment must be equipped with sufficient tools for a minor adjustments to the engine and its accessories. PSCO found all three lifeboats without having sufficient tools as required by LSA Code Chapter IV 4.4.8.27.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2016
Resolved 11 March 2016
Resolution: Received class report stating "Each lifeboat has been supplied with a sealed tool box and safety officer has been instructed to check the tools in each boat during routine inspections."
Electrical › Electrical Distribution System (service) › Junction Box
Issued 3 February 2016 Resolved
Cables and wiring shall be installed and supported in such manner as to avoid chafing and other damage. PSCO found two electrical boxes hanging and unsupported on electrical room next to cabin 6002, deck 6. 74 SOLAS(04)II-1/45.5.5.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 March 2016
Resolved 11 March 2016
Resolution: Received class report stating "the electrical boxes have been properly secured."
Fire Fighting › Means of Escape › Stairways
Issued 3 February 2016 Resolved
Exposed surfaces in stairways enclosures shall have low flame-spread characteristics. PSCO found plywood installed in the overhead and bulkhead of stairwell 8 and landing between decks B and C. 74 SOLAS(97)II-2/34.3.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 February 2016
Resolved 3 February 2016
Resolution: Corrected on the spot by replacing the plywood with steel plates.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 3 February 2016 Resolved
Fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs. PSCO sound combustible materials materials stored above the sprinkler head coverage are in portside safety stowage locker, next to rescue boat launching station. 74 SOLAS(04)II-2/14.2.1.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 February 2016
Resolved 11 March 2016
Resolution: Received class report stating "The combustible materials have been removed from the top shelf and a red line has been painted on the bulkhead noting not to stow items above the line."