VELA STAR is a 2009 freight ship. The Coast Guard has recorded 8 inspections since 2018, most recently in February 2026, along with 8 deficiencies and 2 operational controls.
Records from 2018 to 2026. Most recent: inspection, 4 February 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it27058 - Convention (Subpart B), Net Ton 95905 - Displacement, Metric Ton 83651 - Dead Weight, Metric Ton 44146 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 8
4 February 2026PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8303183
29 January 2026Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8303313
6 December 2025Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8279270
1 November 2024PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8023939
24 October 2024Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8024306
19 September 2022PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7551984
11 - Life Saving Appliances › N/A - No Subsystem › Fast Rescue Boats
Issued 4 February 2026Resolved
ALL ENGINES IN LIFEBOATS AND RESCUE BOATS SHALL BE RUN FOR A TOTAL PERIOD OF NOT LESS 3 MINUTES, PROVIDED THE AMBIENT TEMPERATURE REQUIRED FOR STARTING AND RUNNING THE ENGINE. DURING THIS PERIOD OF TIME, IT SHOULD BE DEMONSTRATED THAT THE GEARBOX AND GEARBOX TRAIN ARE ENGAGING SATISFACTORILY. PSCO OBSERVED THE RESCUE BOAT UNABLE TO ENGAGE FORWARD OR ASTERN PROPULSION USING THE REMOTE LINKAGE FROM THE MAIN HELM POSITION. 02 ATTEMPTS WERE MADE OVER THE COURSE OF OVER 20 MINUTES WITHOUT SUCCESS.
74 SOLAS (20) III/20.6.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 February 2026
Resolved 6 February 2026
Resolution: PSCO observed satisfactory operation of the rescue boat forward and astern propulsion.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 4 February 2026Resolved
THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. PSCO OBSERVED HEAVILY OILED LAGGING UNDER EVERY CYLINDER HEAD ON THE MAIN ENGINE WITH OIL DRIPPING FROM FRAMING, AS WELL AS COLLECTIONS OF OIL IN CONTAINERS STORED IN STORAGE AREAS, INSIDE VOID SPACES IN ENGINE ROOM, AND HEAVILY OILED COMBUSTIBLES BENEATH THE FUEL PURIFYING MACHINERY.
ENGINE ROOM ALSO HAD ASSORTMENTS OF COMBUSTIBLES, INCLUDING OILED RAGS IN BUCKETS AND BOXES ON EVERY LEVEL OF THE ENGINE ROOM AND WITHIN VOID SPACES AS WELL AS STORAGE AREAS IN BOTH.
74 SOLAS (20) II-2/4.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 February 2026
Resolved 6 February 2026
Resolution: Engineering crew relocated materials to locations prescribed by Class. PSCO conducted a satisfactory round of the main engine and auxiliary spaces with the C/E.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 February 2026Resolved
THE PURPOSE OF THIS REGULATION IS TO PROVIDE MEANS OF ESCAPE SO THAT PERSONS ON BOARD CAN SAFELY AND SWIFTLY ESCAPE TO THE LIFEBOAT AND LIFERAFT EMBARKATION DECK. FOR THIS PURPOSE, THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET:
ADDITIONAL AIDS FOR ESCAPE SHALL BE PROVIDED AS NECESSARY TO ENSURE ACCESSIBILITY, CLEAR MARKING, AND ADEQUATE DESIGN FOR EMERGENCY SITUATIONS.
PSCO OBSERVED RESCUE GEAR IN EMERGENCY ESCAPE NOT CORRECTLY STORED TO ALLOW FOR ACTUAL RESCUE. LINE WAS STORED IN A WAY WHERE RESCUERS WOULD NOT BE ABLE TO HOIST THE HARNESSED INDIVIDUALS UPWARDS.
74 SOLAS (20) II-2/13.1.3
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 5 February 2026
Resolved 6 February 2026
Resolution: PSCO verified proper arrangement of means of rescue in the escape trunk. Master also provided proof of a satisfactory rescue drill conducted after arrangements were corrected.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 4 February 2026Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD.
PSCO OBSERVED THE PIPING FOR THE FRESH WATER GENERATOR TO BE HEAVILY CORRODED WITH OVER AN INCH OF BUILDUP AROUND PIPING AND FLANGES. PIPES WERE ADDITIONALLY LEAKING AND CORRODING THE DECK WHERE WATER WAS DRIPPING DOWN TO THE LEVEL BELOW, LEAVING VISIBLE DAMAGE TO THE DECK.
74 SOLAS I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 February 2026
Resolved 6 February 2026
Resolution: PSCO verified proof of overhauling of the FWG piping and observed proper tightness and reduction of corrosion, to include new anti-corrosive paint.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 4 February 2026Resolved
AFTER ANY SURVEY OF THE SHIP UNDER REGULATIONS 10 HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGEMENTS, MACHINERY, EQUIPMENT AND OTHER ITEMS COVERED BY THE SURVEY, WITHOUT THE SANCTION OF THE ADMINISTRATION. PSCO OBSERVED THAT STORAGE RACKS HAD BEEN PLACED IN VOID AREA ABOVE THE ENGINE CONTROL ROOM TO STORE CANS OF WHAT APPEARED TO BE PAINT, AEROSOLS, AND OTHER SUPPLIES.
74SOLAS(20) I/11(b)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 5 February 2026
Resolved 6 February 2026
Resolution: All materials were removed from the location decribed in the deficiency description.
SATISFACTORY MEANS (IN THE FORM OF GUARD RAILS, LIFE LINES, GANGWAYS OR UNDERDECK PASSAGES ETC.) SHALL BE PROVIDED FOR THE PROTECTION OF THE CREW IN GETTING TO AND FROM THEIR QUARTERS, THE MACHINERY SPACE AND ALL OTHER PARTS USED IN THE NECESSARY WORK OF THE SHIP.
PSCO OBSERVED WALKWAY ON BOTTOM LEVEL OF ENGINE ROOM TO HAVE SUPPORT BEAM DETACHED, ALLOWING THE ENTIRE STRUCTURE TO DIP 6 INCHES WHEN STEPPED ON. CREW CORRECTED ON SITE.
ICLL 66 / 25 (4)
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 5 February 2026
Resolved 5 February 2026
Resolution: Corrected on the spot
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 1 November 2024Resolved
Each emergency generator set arranged to be automatically started shall be equipped with starting devices approved by the administration with a stored energy capability of at least three consecutive starts. A second source of energy shall be provided for an additional three starts within 30 minutes unless manual starting can be demonstrated to be effective. PSCO observed #2 battery was removed for replacement.
74 SOLAS 2020
II-1/44.2
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 November 2024
Resolution: Recieved delivery note for replacement battery.
10 - Safety of Navigation › N/A - No Subsystem › Speed and distance indicator
Issued 19 September 2022Resolved
ALL SHIPS OF 300 GT AND UPWARDS SHALL BE FITTED WITH A SPEED AND DISTANCE MEASURING DEVICE. PSCO OBSERVED INOPERABLE SPEED LOG BASED ON CREW REPORT AND FLAG DISPENSATION REQUIRING VESSEL TO HAVE SPEED LOG REPAIRED BY 20 OCT 2022.
SOLAS 74 (2020) V/19.2.3.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2022
Resolved 24 October 2024
Resolution: PSC NOLA received a class reporT from issuing entity satisfying the requirement.