MAURY USCG vessel records
← All vessels

TAHOE SPIRIT

TAHOE SPIRIT is a 2010 tank ship. The Coast Guard has recorded 14 inspections since 2016, most recently in February 2025, along with 5 deficiencies and 3 operational controls.

Records from 2016 to 2025. Most recent: inspection, 24 February 2025.

Built
2010
Last inspected
24 February 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9427641
1087144
Flag
BAHAMAS, THE
Maury page id
psix-1087144

Inspections, by type

…with no type recorded6
Years with a record 7 calendar years (2016–2025)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it49022 - Convention (Subpart B), Net Ton
156877 - Dead Weight, Ton
182538 - Displacement, Ton
83545 - Regulatory (Subpart C or D), Gross Ton
49022 - Regulatory (Subpart C or D), Net Ton
83545 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 14

24 February 2025 COC-TVE Annual · Deficiency Check · PSC B
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8080338
2 January 2024 COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7842999
28 December 2023 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7843141
7 March 2023 PSC B · COC-TVE Annual
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7642065
6 March 2023 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7644388
2 March 2023 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7644664
5 February 2021 Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 7137361
3 February 2021 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7135289
29 January 2021 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7132975
12 May 2020 MARPOL Annex VI Survey · PSC B · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6951482
12 May 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6952346
7 May 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6949736
29 June 2017 COE-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6190166
30 September 2016 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6009755

Deficiency record · 5

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2025 Resolved
Measures shall be taken to the satisfaction of the administration to ensure that the equipment is functioning in a reliable manner and that satisfactory arrangements are made for regular inspections and routine tests to ensure continuous reliable operation. PSCO found the oil mist detectors to be inoperable and in need of maintenance.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2025
Resolution: Sight glasses were replaced with steal plates. See ABS class report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 24 February 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed the main engine cylinders #1,24,5,6 have broken sight glasses. PSCO observed a broken sight glass for the heavy fuel oil line in the purifier room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2025
Resolution: Flag has granted a 30 day dispensation letter due to needing spare parts. see attched ABS class report.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 February 2025 Resolved
In tankers, electrical equipment, cables, and wiring shall not be installed in hazardous locations unless it conforms with the standards not inferior to those acceptable to the organization. PSCO observed lighting in the purifier room to have missing or disconnected grounding wires.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 24 February 2025
Resolution: Corrected ob the spot. Chief engineer installed grounding wires to the lights that were missing them.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 24 February 2025 Resolved
Cargo ships shall carry at least one rescue boat complying with the requirements of section 5.1 of the code. PSCO observed the handholds on the underside of the hull to be deteriorated/broken.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 February 2025
Resolution: Corrected on the spot. Chief mate fixed all handholds on the liferafts that were worn.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 March 2023 Resolved
In tankers, electrical equipment, cables and wiring shall not be installed in hazaardous locations unless it conforms with standards not inferior to those acceptable to the organization, inspector identified 01 explosion proof fixture with 01 broken tombstone on live voltageside of LED bulb with non-voltage side disconnected; one explosion proof fixture with 01 securing cups missing; and 03 bonding straps disconnected/ broken on cargo deck.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 March 2023
Resolved 7 March 2023

Ownership record