This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it9968 - Convention (Subpart B), Net Ton 46551 - Displacement, Metric Ton 37759 - Dead Weight, Metric Ton 23224 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 11
8 February 2019Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6622904
2 February 2019COE-Administrative
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6618985
18 December 2018Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 19 January 2017Resolved
1899- Detailed instruction manual shall be provided on board, covering the operations safety and maintanance requirments and occupational health hazards relevent to the inert gas system. Ths 02 senser for the inert gas generator can not be calibrated according to the manufacturers instructions due to the ship ......See form B.2014 SOLAS (Cons Ed) II-1 Reg 5.5.3.2, 2015 FSS Code Ch 15 2.2.5 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2017
Resolution: Classification Society attended and approroved retro fitted Span gas. Coast Guard and Class witnessed satifactory calibration of the 02 sensor.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.