MAURY USCG vessel records
← All vessels

SEA TROUT

SEA TROUT is a 2010 towing vessel. The Coast Guard has recorded 7 inspections since 2010, most recently in March 2025, along with 2 deficiencies and 2 operational controls.

Records from 2010 to 2025. Most recent: inspection, 14 March 2025.

Built
2010
Last inspected
14 March 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9579377
HK4059
1087444
Flag
COLOMBIA
Maury page id
psix-1087444

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspections, by type

…with no type recorded1
Years with a record 5 calendar years (2010–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it366 - Dead Weight, Ton
916 - Displacement, Ton
475 - Convention (Subpart B), Gross Ton
142 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 7

14 March 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8093766
25 June 2024 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7941957
7 June 2024 PSC A
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7925539
23 March 2023 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7655767
23 March 2023 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7655798
9 March 2019 Ballast Water Examination · CCSSC Examination · ISPS I Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6629527
8 September 2010 MARPOL Annex I Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3845395

Deficiency record · 2

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 June 2024 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed an overhead light in portside engine room missing protective cover. Additionally portside steering solenoid was missing protective cover, leaving wires exposed to possible short or shock hazard. 74SOLAS(04)II-1.45.1.3 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 June 2024
Resolution: Received technician report detailing rectification of the above deficiencies.
Engineering › Lubricating Oil Storage/Transfer System › Flange
Issued 8 September 2010 Resolved
Standard discharge connection is required to be onboard vessels greater than 400 GT. Standard discharge connection not labeled correctly MARPOL 73/78 ANNEX 1/REG 13 Action 70A Code 1760
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 24 September 2010
Resolved 9 March 2019
Resolution: Cleared during CCSSC exam on this date.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.