MAURY USCG vessel records Sign in
← All vessels

XIN HAI TONG 20

XIN HAI TONG 20 is a 2009 freight ship. The Coast Guard has recorded 3 inspections since 2015, most recently in May 2021, along with 3 deficiencies — 1 with no resolution recorded —.

Records from 2015 to 2021. Most recent: inspection, 20 May 2021.

Built
2009
Last inspected
20 May 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9534145 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7A4324
1087558
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1087558

Inspections, by type

…with no type recorded1
…past their stated due date1
Years with a record 2 calendar years (2015–2021)
The 3 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it19191 - Convention (Subpart B), Net Ton
67681 - Displacement, Ton
56753 - Dead Weight, Ton
32983 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ZEFYROS Tank Ship · MISLE 1283719 · 16 December 2015 · activity 5986756

Inspection history · 3

20 May 2021 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7191675
10 May 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7193650
16 December 2015 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5986756

Deficiency record · 3

04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 20 May 2021 Resolved
Where the emergency source of power is a generator, it shall be driven by a suitable prime mover with an independent supply of fuel. PSCO noted fuel rack on prime mover had to be manually manipulated after starting for generator to reach rated voltage and frequency.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 20 May 2021
Resolution: Crew adjusted governor settings and retested to meet desired results.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 20 May 2021 Resolved
Shipowners and operators shall institute a program of hatch cover maintenance. This maintenance shall be directed to keeping all hatch covers drains and their non-return valves in working order. PSCO noted twenty-one hatch cover drains missing their originally provided screw caps.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 May 2021
Resolved 20 May 2021
Resolution: Hatch cover drain valves were restored as original with new end caps.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 May 2021 No resolution recorded
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO noted excessive oil leaking for capstans hydraulic systems located in steering space and bosun stores.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 May 2021 — due date passed with no resolution recorded

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.