MAURY USCG vessel records Sign in
← All vessels

DENSA LION

DENSA LION is a 2010 freight ship. The Coast Guard has recorded 8 inspections since 2010, most recently in April 2022, along with 1 deficiency and 1 operational control.

Records from 2010 to 2022. Most recent: inspection, 26 April 2022.

Built
2010
Last inspected
26 April 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9432464 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HA2379
1087886
Flag
MALTA
—
Maury page id
psix-1087886

Inspections, by type

…with no type recorded2
Years with a record 4 calendar years (2010–2022)
The 8 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it18171 - Convention (Subpart B), Net Ton
64449 - Displacement, Ton
55092 - Dead Weight, Ton
31029 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 8

26 April 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7438747
16 April 2022 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7432067
10 November 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6575822
8 November 2018 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6577061
2 November 2018 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6573441
19 December 2011 ISPS I Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4206473
16 December 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4206472
24 October 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3876452

Deficiency record · 1

Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 19 December 2011 Resolved
0899 - Other Accid/Prev - Each transfer pipe must not leak under static liquid pressure at least one and half times max working pressure. Vessels bunker line was tested with air and not liquid. Provide documentation attesting to satisfactory liquid pressure of bunker lines prior to bunkering in the U.S. - 33CFR156.170
Action required: 703 - Prior to bunkering operations
Due 19 December 2011
Resolved 31 December 2011
Resolution: Received proper documentation from vessel showing bunker lines had been tested with liquid.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.