SAN NICOLAS

SAN NICOLAS is a 2010 freight ship. The Coast Guard has recorded 4 inspections in 2025, along with 4 deficiencies and 1 operational control.

Records in 2025. Most recent: inspection, 12 November 2025.

Built
2010
Last inspected
12 November 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 November 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9463580
V7A5114
1088868
Flag
MARSHALL ISLANDS
Maury page id
psix-1088868

Documentation record

Tonnage as PSIX records it19565 - Convention (Subpart B), Net Ton
69919 - Displacement, Ton
58802 - Dead Weight, Ton
34374 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

12 November 2025 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8267180
8 September 2025 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8229117
7 September 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8228735
13 August 2025 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8202868

Deficiency record · 4

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 August 2025 Resolved
Fixed fire detection and fire alarm system installations shall be suitable for the nature of the space, fire growth potential and potential generation of smoke and gases. PSCO discovered smoke detector disconnected in purifier room machinery space. SOLAS 74 2014, II-2/7.1.1. Code 60ac
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 August 2025
Resolution: Received class report stating the deficiencies have been rectified.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 August 2025 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed active oil leaks from main diesel engine shaft seal and #3 generator. SOLAS 74 2014 II-2/4.1.1, code 60ac.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 August 2025
Resolution: Received class report stating the deficiencies have been rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 13 August 2025 Resolved
Electrical or other equipment which may constitute a source of ignition of flammable vapors shall not be permitted. PSCO observed light fixtures in machinery space near main diesel engine and purifier with broken protective lenses. SOLAS 74 2014 II-1/45.9.2.Code 60ac.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 August 2025
Resolution: Received class report stating the deficiencies have been rectified.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 13 August 2025 Resolved
The company should establish procedures to ensure the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. The technical nature of deficiencies 01,02 and 03 provides objective evidence of a failure of the implementation of the ISM Code. An internal audit report satisfactory to the OCMI must be submitted, prior to the clearance of this deficiency, within 90 days. SOLAS 74 2020IX/3.1. ISM Code 10.1. Code ac.
Action required: 705 - Other - as specified
Due 11 November 2025
Resolved 12 November 2025
Resolution: PSC NOLA received a class report and proper documentation from issuing entity satisfying the requirement

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.