GREEN DELTA

GREEN DELTA is a freight ship. The Coast Guard has recorded 22 inspections since 2016, most recently in May 2026, along with 11 deficiencies, 1 operational control and 1 casualty investigation in 2025.

Records from 2016 to 2026. Most recent: inspection, 20 May 2026.

Built
Not recorded
Last inspected
20 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 May 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9498602
1088871
Flag
UNITED STATES
Maury page id
psix-1088871

Documentation record

Registered dimensions (L × B × D)639.0 ft × 105.8 ft × 82.9 ft
Registered tonnagegross 59,501 / net 17,850
ITC dimensions (L × B × D)639.0 ft × 105.8 ft × 82.9 ft
ITC tonnagegross 59,501 / net 17,850
BuilderSHIN KURUSHIMA TOYOHASHI SHIPBUILDING CO., LTD · TOYOHASHI-SHI, AICHI, JAPAN
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMOBILE, AL
Trade endorsementsRegistry
DocumentationValid · issued 23 September 2025 · expires 30 September 2026
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it17850 - Convention (Subpart B), Net Ton
18056 - Dead Weight, Ton
35002 - Displacement, Ton
59501 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 22

20 May 2026 Vessel Attendance · Administrative Inspection · MSP Annual Oversight · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8380433
2 April 2026 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8341309
22 July 2025 Administrative Inspection · Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8191511
15 April 2025 MSP COI Oversight · Hull Examination · Drydock Exam · Internal Structural Exam · MTSA/ISPS Verification
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8121980
20 March 2025 Administrative Inspection
Administrative · Activities Europe · Activity 8096676
25 February 2025 Administrative Inspection
Administrative · Activities Europe · Activity 8084134
24 February 2025 Administrative Inspection
Administrative · Activities Europe · Activity 8083376
20 February 2025 Type not recorded
No type recorded · Activities Europe · Activity 8202705
10 December 2024 MTSA/ISPS Verification · Initial Certification · MSP Initial Reflag
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 8037354
29 April 2024 PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7899567
1 July 2021 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7241600
24 June 2021 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7234651
10 March 2021 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7153576
27 February 2021 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7143936
27 October 2020 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7085129
4 February 2020 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6902652
23 October 2019 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6840254
24 August 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6788140
21 August 2018 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6518723
13 August 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6503897
16 June 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6172140
2 May 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5863572

Deficiency record · 11

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 December 2024 Resolved
Oil fuel pipes, which, if damaged, would allow oil to escape from a storage, settling or daily service tank having a capacity of 500 liters and above situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space in which such tanks are situated... If such an additional valve is fitted in the machinery space, it shall be operated from a position outside this space. The following quick closing valves did not close: a. #2 Diesel Oil Tank (starboard-side lower Engine Room); b. Fuel Oil 24V port-side suction valve; c. Cylinder Oil head tank; d. Waste Oil tank No. 2; e. Diesel Oil to Boiler. Proper operation of valves shall occur prior to vessel departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 December 2024
Resolved 13 December 2024
Resolution: Valves closed satisfactory on 13DEC2024, witnessed by Class NK (see attached report).
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 December 2024 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. The Emergency Fire Pump pneumatic supply to suction valve is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2025
Resolved 22 January 2025
Resolution: Received Class NK report stating that an inoperative pneumatic supply was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 December 2024 Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation and control. The Fuel Oil inlet low pressure alarms are inoperable on all three generators.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2025
Resolved 22 January 2025
Resolution: Received Class NK report stating that the pressure switch was replaced and adjusted, and an operational test was carried out satisfactory.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 December 2024 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met... means shall be provided to control leaks of flammable liquid. The Emergency Generator fuel supply hose is leaking; and, there is a leaking Fuel Oil transfer pump (which has a catch pan underneath the pump).
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2025
Resolved 22 January 2025
Resolution: Received Class NK report stating that the fuel supply hose was replaced, and that leaking fuel oil transfer pump was rectified by replacing the packing and tighten the bolts.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 December 2024 Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage. Terminations and joints in all conductors shall be so made as to retain the original electrical, mechanical, flame-retarding and, where necessary, fire-resisting properties of the cable. Verify/correct the following: spliced electrical cable in overhead in EDG space, spliced wiring with twist connectors in Electrical Room, and in the lower Engine Room (starboard-side) there are two dead-end cables and several cables hanging unsupported from the overhead.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2025
Resolved 22 January 2025
Resolution: Received Class NK report stating that the spliced cable was connected by/in a junction box, and the hanging cables were secured by bands.
08 - Alarms › N/A - No Subsystem › UMS - alarms
Issued 12 December 2024 Resolved
The arrangements provided shall be such as to ensure that the safety of the ship in all sailing conditions, including maneuvering, is equivalent to that of a ship having the machinery spaces manned. A personnel alarm must be provided and must annunciate on the bridge if not routinely acknowledged at the ECC or in the machinery spaces. A personnel alarm (dead man alarm) must be provided and must annunciate on the Navigation Bridge if not routinely acknowledged at the centralized control station or in the machinery space. Update Gap Analysis and provide risk mitigation plan to operate in PUMS until such an alarm is installed by next dry-dock. (NOTE: an acceptable risk assessment/mitigation plan was provided on 18DEC2024).
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 May 2025
Resolved 14 May 2025
Resolution: Verified installation and tested at COI Renewal MISLE Activity 8121980.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 12 December 2024 Resolved
Administration shall give special consideration to... the location and centralization of the fire-extinguishing system controls... All required fire pump control locations must include the controls necessary to charge the fire main and have (1) a fire main pressure indicator or (2) a fire main low pressure alarm. The Emergency Gear Locker Control Station does not have a fire main pressure indicator. Update Gap Analysis and provide risk mitigation plan to operate in PUMS until such an indicator is installed by next dry-dock. (NOTE: an acceptable risk assessment/mitigation plan was provided on 18DEC2024).
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 May 2025
Resolved 14 May 2025
Resolution: Verified installation and test at COI Renewal MISLE Activity 8121980.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 December 2024 Resolved
Measures shall be taken to the satisfaction of the Administration to ensure that the equipment is functioning in a reliable manner and that satisfactory arrangements are made for regular inspections and routine tests to ensure continuous reliable operation. Tests must verify that automated vital systems are designed, constructed, and operate in accordance with all applicable requirements... The tests must be based upon the failure analysis,..., functional performance requirements, and the Periodic Safety tests. All PSTPs need to be verified, and at a minimum the following need to be updated by next dry-dock: a. Testing of generator exhaust temperatures; b. Steering gear alarm "high temperature" should be low level; c. Indication of manual over-speed trip (push button) of generators (though this is not applicable); d. Jacket water set point alarms at 85 degrees (vs. the stated 90 degrees); e. Update procedure 6-D-2 for Emergency Generator fail alarm; f. Procedure 6-D-7 states EDG overspeed should shut down the engine, however it currently only alarms (and does not shutdown); g. Procedure 7-A-3 for Auxiliary Boiler high water alarm setting is listed as 220mm, however should be 110mm; h. Update procedure 7-A-4; i. Update procedures 7-A-7 and 7-A-8 for Auxiliary Boilers fuel oil inlet low and high; j. Update procedure 7-A-9 (title “Alarm and Trip”); k. For procedure 7-A-10, the vessel does not have the proper testing equipment, and update for the set point; l. Procedure 7-A-11, salinity high alarm (review and update); m. Update procedures 7-B-1 through 7-B-16 (for the Incinerator); n. Update procedure 6-G-3 to list the correct sequential start equipment.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 19 May 2025
Resolved 22 July 2025
Resolution: Resolved in MISLE Activity 8191511.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 December 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Complete the following as worklist items by completion of next drydock: a. Verify and provide evidence that oil mist detection is not required on the three vessel generators; b. Generators 1 and 3 have evidence of jacket water leakage, correct as necessary; c. Obtain and calibrate all proper testing equipment for conducting PSTPs; d. Correct broken Fuel Oil Shifter Pump Gauge; e. Verify the material of drinking water piping onboard and provide details on acceptable usage for the PVC piping made in accordance with JIS K6742 (based on ISO 1452-1 and ISO 1452-2); f. Correct inoperable EDG Cooling Water Temperature high alarm; g. Insulation on Diesel Oil Tank (Port) valve shows signs of oil soakage; h. No relief valves on the air receivers (install or verify acceptance as is); i. Correct small leak on Fuel Oil Purifier #2.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 May 2025
Resolved 22 July 2025
Resolution: Resolved in MISLE Activity 8191511.
01 - Certificates & Documentation › 012 - Crew Certificates › Endorsement by flagstate
Issued 13 August 2018 Resolved
The endorsements referred to in paragraphs 5, 6, and 7 of STCW regulation I/2 shall expire as soon as the certificate endorsed expires. Multiple Japanese endorsements issued to the ship's crew have expiration dates beyond the certificate they endorse. - '78 STCW I.2.8.4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 August 2018
Resolution: Recieved proper documentation from flag stating the following: "in Japan, we issue endorsement document for 5 years but the endorsement becomes invalid if the certificate endorced expires according to provision of paragraph 8.4 Reg I/2 of STCW 2010."
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 August 2018 Resolved
To discharge ballast water into U.S. Waters, the Master in charge of a vessel subject to 33CFR151.2025 must ensure the water meets discharge standards in 151.2025(a), use an AMS (151.2025(a)(3)) or ballast with water from a U.S. public water system. The vessel's owners did not have a ballast water treatment system installed at its dry-docking in June 2018. The vessel's management does not plan to discharge in the U.S. and acknowledges it is not authorized to do so.
Action required: 705 - Other - as specified
Resolved 4 February 2020
Resolution: Reviewed NBIC reports showing the vessel will not discharge ballast water in the U.S.

Casualty record · 1

20 February 2025Routine · role: Involved in a Marine Casualty · activity 8202705
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

ERIDANUS LEADER (2025). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.