Records from 2017 to 2023. Most recent: inspection, 10 April 2023.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 8 February 2017
Resolved
0615 - RESCUE BOATS - RESCUE BOATS SHALL BE STOWED IN A STATE OF CONTINUOUS READINESS FOR LAUNCHING IN NOT MORE THAN 5 MINUTES. RESCUE BOAT WAS NOT STOWED IN A STATE OF CONTINUOUS READINESS; SHIP'S CREW COULD NOT START THE RESCUE BOAT ENGINE. SOLAS 74(14 CONS) III/14.1 - 30ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2017
Resolution: Rescue boat engine repaired and tested to the satisfaction of Classification Society and attending USCG inspector. Classificaiton Society report received.
Lifesaving › Rescue Boat Equipment › Thermal Protective Aid
Issued 8 February 2017
Resolved
0615 - RESCUE BOATS - THE RESCUE BOAT EQUIPMENT, INCLUDING THERMAL PROTECTIVE AIDS, FIRE EXTINGUISHER, AND RESCUE QUOITS, WERE NOT STORED WITHIN THE RESCUE BOAT. THE EQUIPMENT WAS LOCATED IN A LOCKER NEAR THE EXHAUST STACK ON B DECK, ONE DECK ABOVE AND ON THE OPPOSITE SIDE OF THE VESSEL FROM THE RESCUE BOAT. SOLAS 74 (14 CONS) III/31.2 LSA CODE V/5.1.2.1 - 30ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2017
Resolution: Class verified and provided report attesting to all required equipment moved and stored in the rescue boat.
Electrical › Electrical Distribution System (service) › Busway
Issued 8 February 2017
Resolved
0899-Other(accid. prevent)-Electrical Installation shall be such that the safety of the crew and ship from electrical hazards will be ensured. A pin-hole leak was discovered on a hot water supply line in the vicinity of an electrical panel located in the C-deck cable trunk space. Leak is in the direction of the bulkhead opposite the electrical panels,with minor pooling on deck.SOLAS(14)II-1/40.1.3
Action required: 705 - Other - as specified
Due 10 March 2017
Resolved 9 February 2017
Resolution: Class report received attesting to satisfactory repairs to hot water line.
Fire Fighting › Structural - A Class Divisions › Stairways
Issued 8 February 2017
Resolved
0750 - Fire Prevention - Doors required to be self-closing shall not be fitted with hold-back hooks. The sself-closing door between the provisions store and galley was fitted with a hold-back hook. The fire control plan designates this door as a sself-closing door. SOLAS(09)II-2/9.4.2.2 - 10c
Action required: 705 - Other - as specified
Due 8 February 2017
Resolved 8 February 2017
Resolution: The hold-back hook was removed from door and wall while PSCO team was still onboard.
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 8 February 2017
Resolved
2120 - Garbage - Every ship of 100 gross tons and above shall carry a garbage management plan which the crew shall follow. A broken washing machine in the crew laundry space was used as a waste recepticle for plastics. This is inconsistent with the garbage management plan for storing plastics. MARPOL 73/78(11) V/9.2 -10c
Action required: 705 - Other - as specified
Due 8 February 2017
Resolved 8 February 2017
Resolution: The garbage was removed from broken washing machine.