← All vessels
CREW RUNNER
Passenger (Inspected) · Passenger Ship class · Built 2010s · USCG Heartland District (CGD-H) · Other hulls named CREW RUNNER
CREW RUNNER is a 2011 passenger vessel (inspected). The Coast Guard has recorded 22 inspections since 2010, most recently in March 2026, along with 38 deficiencies, 1 operational control and 2 casualty investigations between 2017 and 2018.
Records from 2010 to 2026. Most recent: inspection, 5 March 2026.
- Built
- 2011
- Last inspected
- 5 March 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 38 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2017–2018
Identity
1231333
WDE9082
1090725
Flag
UNITED STATES
367687190
Maury page id
psix-1090725
Inspections, by type
…with no type recorded3
Years with a record
15 calendar years (2010–2026)
The 22 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)50.0 ft × 14.0 ft × 4.0 ft
Registered tonnagegross 23 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderAMERICAN ALUMINUM MARINE LLC · GONZALES, LA, UNITED STATES · built 2011
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 19 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23 - Simplified, Gross Ton
23 - Simplified, Net Ton
23 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDI3328MMSI 367687190 · active · compulsorily equipped · granted 9 June 2025, expires 6 August 2035
WDG8836MMSI 367581550 · cancelled · compulsorily equipped · granted 2 July 2013, cancelled 9 June 2022 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 22
5 March 2026
Simplified Stability Test · Drydock Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8320540
24 April 2025
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8091035
7 March 2024
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7875470
17 April 2023
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7647004
2 June 2022
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7454460
9 April 2022
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7427805
8 July 2020
Drydock Exam · Construction Oversight · Simplified Stability Test · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7001118
21 January 2020
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6868568
7 January 2019
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6606681
28 September 2018
Examination of Repairs · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6552757
19 June 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6495927
10 January 2018
Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6331390
11 September 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6264702
7 September 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6265968
19 January 2017
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6070476
5 December 2016
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6050704
5 January 2016
Administrative Inspection · Internal Structural Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5788974
2 September 2015
Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5228864
5 August 2014
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4944897
6 January 2012
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4216064
26 January 2011
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3933299
19 October 2010
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3877930
Deficiency record · 38
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 March 2026
Resolved
A vessel that is exposed to salt water for not more than three months in any 12 month period since the last examination must undergo a drydock examination at least once every five years. MI observed that the vessel had been operating beyond its drydock due date of 30NOV2025. Overdue drydock examination was conducted to the satisfaction of the attending MI. 46 CFR 176.600 (c)(2)
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 17 April 2023
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. The flame screens or flame arresters must be of such size and design as to prevent reduction in the net cross sectional area of the vent pipe and permit cleaning or renewal of the flame screens or arrester elements. Vessel does not have flame screens on the fuel tank vents. 46CFR182.450(e)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 April 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions. Water discovered in battery tray. Remove water. 46CFR183.200(a)
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 April 2023
Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and paint lockers. E/R hatch covers missing gasket material. 46CFR177.405(e)
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 April 2023
Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces
and paint lockers. Electrical cable running from E/R to bridge console not gas tight. Crew member added fire stop during inspection.46CFR177.405(e)
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 August 2022
Resolved
A vessel must carry either a first aid kit approved
under approval series 160.041 or a kit with equivalent
contents and instructions. MIs noted that the required
aspirin was expired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 April 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew.
Vessel struck a ship mooring buoy causing damage to the starboard stern bumper and stairs used for onloading/offloading crew and passengers.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 July 2021
Resolved
46 CFR 183.380(d) - conductors must be protected in accordance with their current carrying capacities. The approved DC electrical plans (NDC Dwg. No. 821, Rev. B) call for a 200 amp fuse between the house battery bank disconnect switch and the house battery selector switch. This fuse was not installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 24 January 2020
Resolved
Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passenger or crew. Vessel did not have railings or equivalent protection installed at the port and starboard ends of the bow or stern. Install rails or chains to the satisfaction of the attending Marine Inspector before 26 January 2020.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 24 January 2020
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure including inspection and operation of all watertight closures in the hull, decks, and bulkheads. Marine inspector identified cracking of frame for the forward-most deck hatch on the bow. Repair to the satisfaction of the attending marine inspector at the vessel's next scheduled dry-dock in July 2020.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 January 2019
Resolved
EXHAUST PIPING REQUIRES LAGGING ON NON-COOLED PORTIONS. EXHAUST SIDE OF TURBOCHARGER ON BOTH ENGINES IS MISSING LAGGING. REPAIR TO SATISFACTION OF ATTENDING MARINE INSPECTOR. 46 CFR 182.430(a) 16c
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 January 2019
Resolved
DRAIN VALVES ON FUEL FILTERS REQUIRE THREADED PLUGS OR CAPS. BOTH RACOR FUEL FILTER DRAIN VALVES WERE MISSING PLUGS. REPAIR TO SATISFACTION OF ATTENDING MARINE INSPECTOR. 46 CFR 182.458(b)(9) 16c
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 January 2019
Resolved
WIRING REQUIRED TO BE SUPPORTED. PORT ENGINE HARNESS WAS NOT SECURED AND LAYING IN BILGE INFRONT OF ENGINE. REPAIR TO SATISFACTION OF ATTENDING MARINE INSPECTOR. 46 CFR 183.340(b)(4) 16c
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 January 2019
Resolved
BULKHEAD OPENINGS REQUIRED TO BE WATERTIGHT. BOTH FWD BULKHEADS HAD THREADED OPENINGS WITH NO MEANS OF SEALING THEM. PROVIDE PLUGS OR MEANS OF MAKING THEM WATERTIGHT TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. 46 CFR 179.310(a)(2) 16c
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 January 2019
Resolved
CABLE AND WIRING REQUIRED TO BE PROTECTED. GENERATOR CABLE PROTRUDING AFT PILOTHOUSE BULKHEAD HAD LOOSE FITTING AND WAS CHAFFING. REPAIR TO SATISFACTION OF ATTENDING MARINE INSPECTOR. 46 CFR 183.340 16c
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 January 2019
Resolved
LIFE JACKETS REQUIRED FOR EACH PERSON CARRIED ONBOARD. 2 LIFE JACKETS MISSING. REDUCE PASSENGER COUNT TO 26 UNTIL PROPER AMOUNT ONBOARD PROVEN TO SATISFACTION OF ATTENDING MARINE INSPECTOR. 46 CFR 180.71(a) 16c
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 January 2019
Resolved
EACH RING LIFE BUOY MUST BE MARKED IN CLEARLY LEGIBLE BLOCK CAPITAL LETTERS WITH THE VESSEL'S NAME. RING LIFE BUOY DID NOT HAVE ANY MARKINGS ONBOARD. PROVIDE PROOF THAT VESSEL NAME IS CLEARLY MARKED ON RING LIFE BUOY. 46 CFR 185.604(b) 16c
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 September 2018
Resolved
STBD MDE EXPERIENCED PROPULSION CASUALTY DUE TO FAILURE OF THE COOLING SYSTEM. CONDUCT REPAIRS AND TEST FULL OPERATIONAL PARAMETERS TO SATISFACTION OF ATTENDING USCG MARINE INSPECTOR.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 September 2018
Resolved
FOUND EXCESSIVE ACCUMULATION OF OILY WATER IN E/R BILGES AND UNDER DIESEL FUEL TANK. CLEAN TO SATISFACTION OF ATTENDING USCG MARINE INSPECTOR.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 September 2018
Resolved
FOUND CONTROL / INSTRUMENTATION WIRING BUNDLE WAS RUN EXCESSIVELY LOW AS TO BE SUBMERGED IN BILGE WATER. SECURE WIRING TO SATISFACTION OF ATTENDING USCG MARINE INSPECTOR.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 28 September 2018
Resolved
FWD E/R BILGE HIGH LEVEL SWITCH HOUSING WAS MOUNTED IMPROPERLY (HANGING FROM ITS WIRING INTO BILGE). SECURE HOUSING TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR.
Deck/Cargo › Mooring/Anchoring › Mooring Arrangement
Issued 10 January 2018
Resolved
Both port side mooring bits have cracks in the deck at their bases. Repair to the satisfaction of Marine Inspector.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 10 January 2018
Resolved
Ring buoy lifeline spliced, degraded and not of UV-resistant material. Renew/replace to satisfaction of Marine Inspector.
Engineering › Bilge Water Management System › Valve
Issued 10 January 2018
Resolved
No positive shut off valve installed at the hull penetration on engine room submersible electric bilge pump. Install shut off valve to satisfaction of attending marine inspector.
Personnel › Training › Familiarization Training
Issued 11 September 2017
Resolved
Failure contact USCG with reportable marine casualty. Provide training to crew on requirements to report.
Construction/Loadline › Hull › Transverse Frame
Issued 19 January 2017
Resolved
Crack in transom immediately above port side exhauast pipe spanning over an inch. The crack is below the waterline. 46 cfr 176.110
Electrical › Electric Supply System (service) › Cable
Issued 19 January 2017
Resolved
Dead end wires near port engine exhaust and starboard outboard of fuel tank. 46 cfr 183.200
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 5 January 2016
Resolved
Bilge pumps are inoperable.
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 January 2016
Resolved
Bilge alarms inoperable.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 January 2016
Resolved
Floating ring buoy light not floating due to incorrect battery installed
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 5 January 2016
Resolved
Must have means to close supply cowls/scoops and exhaust discharges.
Fire Fighting › Fire Bucket › Stenciling
Issued 5 January 2016
Resolved
Must have words "fire bucket" stenciled on fire bucket in contrasting color
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 5 January 2016
Resolved
Stencil name of vessel on life preserver
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 2 September 2015
Resolved
machinery space vent closures missing.
Engineering › Bilge Water Management System › Interface Detector
Issued 2 September 2015
Resolved
Machinery space bilge alarm not working.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 2 September 2015
Resolved
Deviation table done in 2011. Vsl just completed a engine modification that required extensive welding on the hull and equiptment changes to the consol around the compass.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 17 January 2012
Resolved
No operators manual could be located, unable to prove shutdown of required powered ventilation as per 46CFR181.420.
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 January 2012
Resolved
Batteries are located in the same compartment as the gasoline fuel tank. Relocate batteries and ensure proper installation as per 46CFR183.350.
Casualty record · 2
7 September 2017Routine · role: Involved in a Marine Casualty · activity 6265968
19 June 2018Routine · role: Involved in a Marine Casualty · activity 6495927
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.