← All vessels
TREASURE STAR
TREASURE STAR is a 2010 freight ship. The Coast Guard has recorded 9 inspections since 2016, most recently in January 2026, along with 17 deficiencies — 4 with no resolution recorded — and 3 operational controls.
Records from 2016 to 2026. Most recent: operational control imposed, 30 January 2026.
- Built
- 2010
- Last inspected
- 30 January 2026
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 17 recorded · 4 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
Inspections, by type
The 9 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Documentation record
Tonnage as PSIX records it43012 - Convention (Subpart B), Gross Ton
27239 - Convention (Subpart B), Net Ton
82206 - Dead Weight, Metric Ton
94350 - Displacement, Metric Ton
27239 - Convention (Subpart B), Net Ton
82206 - Dead Weight, Metric Ton
94350 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 9
30 January 2026
PSC B · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8304024
30 January 2026
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8304066
13 June 2023
PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7701771
22 October 2021
PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7334842
16 July 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6481044
28 October 2016
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6030654
26 March 2016
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5822277
10 March 2016
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5831096
4 January 2016
PII Safety Exam · Administrative Inspection · ISPS II Exam · Ballast Water Examination · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5787281
Deficiency record · 17
09 - Working and Living Conditions › 092 - Working Conditions › Gas instruments
Issued 2 February 2026
Resolved
The adminstration shall take steps to ensure that crews of ships are trained in the use of such instruments. PSCO observed crew unable to perform gas detention testing, calibration and did not have gas detection instructions onboard.
74SOLAS(24)
VI/3.2
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 2 February 2026
No resolution recorded
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established. Due to the technical and operational nature of the deficiencies listed, PSCO observed the vessels crew has failed to implement the vessels safety management system. A internal audit report satisfactory to the COTP must be submitted prior to clearance of this deficiency within 90 days.
74 SOLAS (24)
IX/3.1
ISM Code 10.1
04 - Emergency Systems › N/A - No Subsystem › Enclosed space entry and rescue drills
Issued 2 February 2026
No resolution recorded
Crew members enclosed space entry or rescue responsibilities shall participate in an enclosed space entry and rescue drill to be held onboard the ship at least once every two months. PSCO observed vessel did not conduct enclosed space drill within two months after September 9th 2025 drill.
74 SOLAS (24)
III/19.3.3
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 February 2026
No resolution recorded
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that ship in all aspects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed excessive mechanical seal leakage from ships fire/bilge pump.
74 SOLAS (24)
I/11(a)
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 2 February 2026
No resolution recorded
The training manual shall explain the following in detail: Escape systems and appliances. PSCO identified 03 EEBD types onboard vessel while SOLAS training manual only had instructions for 01 type.
74 SOLAS (24)
II-2/15.2.3.4.7
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 2 February 2026
Resolved
Oil fuel pipes, which, if damaged would allow oil to escape from a storage, settling or daily service tank have a capacity of 500L and above shall be fitting with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space in such tanks are situated. PSCO observed bolts placed to prevent quick closing valve from closing
74 SOLAS (24)
II-2/4.2.2.3.4
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 2 February 2026
Resolved
Rescue boats shall be stowed: in a state of continuous readiness for launching in not more than 5 min, and if the inflated type, in a fully inflated condition at all times. PSCO observed rescue boat engine not operating as design for 40 minutes.
74 SOLAS (24)
III/14.1
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 22 October 2021
Resolved
02105-Other(clearly hazardous)-THE MACHINERY, BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. PSCO DISCOVERED STEERING GEAR DRIFT APPROXIMATELY ONE DEGREE EVERY 30 SECONDS IN LOCAL CONTROL ON BOTH STEERING PUMPS. 74 SOLAS (20) II-1/26.1
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 22 October 2021
Resolved
15113-Other(clearly hazardous)-The company should establish procedures, plans, and instructions, including checklists as appropriate for key shipboard operations concerning the safety of the personnel ship and protection of the environment. Ship's cyber security procedure requires crew training which was not conducted. Vessel shall conduct crew training on cyber security procedure. 74 SOLAS (20) IX-3.1 ISM Code A Reg 7-17ac
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 22 October 2021
Resolved
02105-Other(clearly hazardous)-The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed failure to operate steering gear, number one pump, from bridge control.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 16 July 2018
Resolved
ALL LIFESAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. WHILE ATTEMPTING TO RUN THE RESCUE BOAT NO WATER WAS OBSERVED COMING FROM THE COOLING PORTS. WHICH IS AN INDICATOR OF OVER HEATING IN ACCORDANCE WITH OPERATOR'S MANUAL, ADDITIONALLY, INDICATING ENGINE IS NOT BEING OPERATED AS REQUIRED BY THE INSTRUCTION MANUAL. 0615 74 SOLAS (14) III/20 17AC
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 28 October 2016
Resolved
2550: The function of fixed fire detection systems shall be periodically tested by means of equipment producing phenomena associated with incipient fires to which the detector is designed to respond. The crew is using a cigarette lighter to test the flame detectors, 74 SOLAS (14con) II-2/7.3.2, 17C.
Operations/Management › Drills/Instruction › Not Conducted
Issued 28 October 2016
Resolved
0899: Each enclosed space entry and rescue drill shall include checking and use of rescue equipment and procedures. Enclosed space stretcher has grommets missing and is not of appropriate size for all crew members. Use in current condition could cause physical injury. 74 SOLAS (14con) III/19.3.6.2.4, 17C.
Documentation › Manuals/Policy Documentation › Dedicated Clean Ballast Tanks Operations Manual
Issued 28 October 2016
Resolved
2510: Vessel must maintain a ballast water management plan and bio-fouling management plan that has been developed specifically for the vessel that will allow those responsible for the plan to understand and follow it. Vessel does not have a bio-foulling management plan. 33CFR 151.2050(g), IMO Res., 207(62), 40C.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Piping
Issued 4 January 2016
Resolved
0720-Fire fighting equipment-The water-mist system was disabled by the crew due to faults on the fire detection panel, causing continuous release of water-mist over the #3 generator set when the system is in the auto position. 74 SOLAS (2014 CONS.) II-2/14.4.1.1.3;FSS Code Ch.
8.2.5.1...see narative.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 4 January 2016
Resolved
2515-Company responsibility and authority-The vessel notified the company of faults detected on the fire detection panel. Upon notification, the company failed to take action to rectify the fault condition, rendering the water-mist system inoperable. 74 SOLAS (2014 CONS.)IX/3.1
ISM CODE PART A 10.2.3 see narative
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 4 January 2016
Resolved
0950-Electric equipment in general-A second source of energy shall be provided for an additional three starts within 30 min unless manual starting can be demonstrated to be effective. The second set of start batteries was found to be inoperable at the time of inspection. 74 SOLAS (2014CONS.) II-1/44.2
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.