MELISSA RENEE

MELISSA RENEE is a 2011 passenger vessel (inspected). The Coast Guard has recorded 8 inspections since 2018, most recently in October 2024, along with 58 deficiencies and 3 operational controls.

Records from 2018 to 2024. Most recent: operational control imposed, 1 October 2024.

Built
2011
Last inspected
1 October 2024
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDL2441
1092324
Flag
UNITED STATES
Maury page id
psix-1092324

Inspections, by type

Years with a record 5 calendar years (2018–2024)
The 8 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)29.0 ft × 12.0 ft × 5.4 ft
Registered tonnagegross 12 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEA HAWK BOATS · SEBRING, FL, UNITED STATES · built 2011
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMARATHON, FL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 12 May 2011
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 8

1 October 2024 COI Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7995143
17 September 2024 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7979594
10 January 2024 Examination of Repairs · Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7847479
13 October 2022 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7577305
20 September 2022 Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7562566
13 August 2021 Administrative Inspection · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7285637
27 October 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7084772
21 September 2018 Internal Structural Exam · Drydock Exam · COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6545627

Deficiency record · 58

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 October 2024 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Replace 01 Adult life jacket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2024
Resolved 11 October 2024
Resolution: Life jacket has been replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 1 October 2024 Resolved
Each item of survival craft equipment must be good quality and efficient for the purpose it is intended to serve. Life float needs to be painted with proper paint.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2024
Resolved 30 October 2024
Resolution: LF has been painted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 October 2024 Resolved
Each portable fire extinguisher on a vessel must be of a approved type. Replace broken fire bracket in FWD compartment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2024
Resolved 11 October 2024
Resolution: Bracket has been replaced.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 October 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:Charts, U.S. Coast Pilot,Light list, Tide tables.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2024
Resolved 30 October 2024
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 1 October 2024 Resolved
A vessel must comply with applicable requirements for any radio requirements for a station license and installations set forth be FCC. Vessel needs a new FCC safety certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2024
Resolved 30 October 2024
Resolution: Got FCC CERT.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 October 2024 Resolved
All vessels must have navigation lights that are in compliance. Remount missing screws in port nav light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2024
Resolved 11 October 2024
Resolution: Port NAV light has been repaired.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 1 October 2024 Resolved
Remote fuel shut off stations must be marked in clearly legible letters at least 1 inch high indicating purpose of valve and direction of operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2024
Resolved 30 October 2024
Resolution: F/O shut off's labeled.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 October 2024 Resolved
The following space must be equipped with a fix gas fire extinguishing system. A space containing an internal combustion engine of more than 50hp. Vessel was unable to test fire boy system for marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 October 2024
Resolved 11 October 2024
Resolution: Test of fire boy system has been completed. All SAT.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 1 October 2024 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure all crew members are familiar with their duties. Vessel needs to conduct drills with marine inspector and needs to post emergency instructions on vessel not in binder.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 October 2024
Resolved 30 October 2024
Resolution: Conducted drills.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 1 October 2024 Resolved
A fire boy fire extinguishing system requires all ventilation ports be able to be secured in case of a engine room fire. Repair port side ventilation handle does not work properly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2024
Resolved 11 October 2024
Resolution: Handle has been fixed to ventilation system to engine room.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 January 2024 Resolved
One 40-B-C fire extinguisher was found with a low charge. Must charge or replace with CG approved fire extinguisher prior to carrying passengers.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2024
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 10 January 2024 Resolved
Port side engineroom ventilation will not stay shut. Must make repairs and test to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 February 2024
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 January 2024 Resolved
Vessel is required to have 12 flares. Vessel was found with only 6 red flares. Must replace missing 6 flares prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 January 2024 Resolved
10 adult life jackets were found with faded/worn retro reflective tape. Must replace all retro tape on all 10 adult life jackets to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2024
Resolved 16 January 2024
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 10 January 2024 Resolved
EPIRB was found with expired registration. Must renew registration and provide documentation of valid registration. Vessel is limited to one mile from shore until cleared.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2024
Resolved 16 January 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 January 2024 Resolved
Life ring light was not working. Must make repairs or replace and test to the satisfaction of attending CG Marine Inspector. Vessel limited to daylight hours only until cleared.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2024
Resolved 16 January 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 January 2024 Resolved
Life ring on stern was found in un serviceable condition. Must replace life ring on the stern.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2024
Resolved 16 January 2024
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 January 2024 Resolved
First aid kit was found with several expired items. Must update first aid kit to meet the requirements in 160.041
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2024
Resolved 16 January 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 January 2024 Resolved
Both port and STBD emergency fuel shut off valves were not labeled. Must labeled both emergency fuel shut off valves to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2024
Resolved 16 January 2024
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 October 2022 Resolved
Aft high water alarm light not working. Make repairs and test to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2022
Resolved 9 November 2022
Resolution: New light installed and tested SAT
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 13 October 2022 Resolved
Hydro static release for the EPIRB expired back in 2021. Must replace hydro static release.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2022
Resolved 9 November 2022
Resolution: New hydrostatic release installed
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 October 2022 Resolved
First aid kit had expired items. Must replace expired items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2022
Resolved 9 November 2022
Resolution: New first aid kit meeting requirements on board
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 October 2022 Resolved
9 Adult life jackets had faded/worn retro tape. Replace all retro tape on the 9 life jackets.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2022
Resolved 13 October 2022
Resolution: Replaced all retro tape before end of inspection
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 October 2022 Resolved
2 of the 3 fire buckets were not labeled. Must label buckets with "FIRE BUCKET"
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2022
Resolved 9 November 2022
Resolution: All buckets labeled correctly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 October 2021 Resolved
4 adult life jackets has worn/faded retro tape. Replace all retro tape on those life jackets with SOLAS retro tape.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2021
Resolved 25 October 2021
Resolution: Replaced all retro on life jackets
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 October 2021 Resolved
Life float was found with fade/worn retro tape. Must replace all retro with SOLAS retro tape.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2021
Resolved 25 October 2021
Resolution: Relaced all retro tape on life float.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 October 2021 Resolved
First aid kit was found with missing items. Must replace missing items to meet requirements.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2021
Resolved 25 October 2021
Resolution: Replaced missing items in first aid kit
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 October 2021 Resolved
All 3 fire buckets were only 2 gallons each. Must be 2.5 gallons. Replace all 3 buckets with at least 2.5 gallons, attach lanyards and label properly
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2021
Resolved 25 October 2021
Resolution: Replaced all 3 fire buckets with 3 gallon buckets, labeled and lanyards attached
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 7 October 2021 Resolved
Front guard was missing on MDE. Must Replace missing guard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2021
Resolved 25 October 2021
Resolution: Installed missing engine guard
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 7 October 2021 Resolved
Missing crew training logs. Must show proof of crew training for new hire and every 3 months after.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2021
Resolved 1 December 2021
Resolution: Provided Crew Training log for new hires as required.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 August 2021 Resolved
Vessel failed to have its Annual inspection conducted within the 90 day prior or 90 after COI anniversary date of OCT 17th. COI is no longer valid and can not operate with more than 6 passengers until new COI inspection is completed.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 13 August 2021
Resolved 7 October 2021
Resolution: Conducted annual inspection
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 August 2019 Resolved
Supply vessel with auxiliary means of steering that is of adequate strength, and that is capable of moving the rudder 15 degrees to either side.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: Axillary tiller provided for vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 August 2019 Resolved
Post sign on main deck stating “OFFICIAL DOCUMENTS AVAILABLE UPON REQUEST” in lieu of posting COI and Stability letter. Letters must be at-least 1/2in tall.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: Sign posted to the satisfaction of USCG.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 27 August 2019 Resolved
Provide FCC station license and FCC safety radio certificate (certifying the radio installation).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: FCC safety certificate provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 August 2019 Resolved
Provide means to physically separate Child PFDs from Adult PFDs, all PFDs are stowed in same compartment.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: PFD's separated by physical means in forward compartment.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 August 2019 Resolved
Provide first aid kit that has all contents as per 46CFR160.041, Ammonia Inhalants need to be replaced.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: New medical kit provided.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 27 August 2019 Resolved
Replace/repair rail courses at embarkation stations (03), connection points for chains were wasted.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: Chains replaced.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 27 August 2019 Resolved
Provide up to date Marine charts for area of operation, charts shall be of adequate scale.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: Adequate chart provided.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 27 August 2019 Resolved
Provide tide and current tables for area of operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: Publications onboard.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 27 August 2019 Resolved
VHF radio shall have MMSI# programed and GPS supplied to broadcast in case of emergency.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: MMSI# programed and GPS supplied to VHF.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 27 August 2019 Resolved
Provide durable emergency broadcast placard next to vhf radio.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: Placard at op station.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 27 August 2019 Resolved
Provide access to shutoff valves for submersible bilge pumps overboard discharge (Forward Compartment/Engine Room). Unable to verify if valves are installed or operational.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: Six inch access plate installed, verified shutoff valves were installed on hull.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 August 2019 Resolved
Repair cross-member for hydraulic steering ram, bolts were found backed out and cross-member was moving during rudder movement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: Cross member reinstalled and properly supporting steering system.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 August 2019 Resolved
Replace portable fire extinguisher at operating station (10-B:C), gauge was found in the red.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: New portable fire extinguisher provided.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 27 August 2019 Resolved
Provide flame screen for port side fuel tank vent pipe. Screen must be at least 30 by 30 mesh that is corrosion resistant.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: New flame screen installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 August 2019 Resolved
Wiring must be installed with metal supports spaced not more than 24 inches, plastic zip ties are ONLY to be used for bundling.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: Wiring under op station properly supported.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 27 August 2019 Resolved
Provide two portable flashlights, one shall be stored at operating station and one near access to engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: Portable lighting supplied.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 August 2019 Resolved
Electrical distribution panel shall be installed as per approved vessel plans dated (20JAN2011). Provide documentation that circuit breakers meet UL-489 and they are sized according to current carrying capacities.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: Verified breakers were UL listed (BLUESEAS) and properly sized for each supplied circuit per approved plans.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 August 2019 Resolved
Repair/replace vessel name on STBD bow
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: Name applied.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 August 2019 Resolved
Remove (03) 12volt cigarette lighters Electrical installation under console, wire not boat cable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: Cable replaced with boat cable and properly fused for overcurrent.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 August 2019 Resolved
Vessel constructed with general purpose resin. Provide smoke activated fire detection system of an approved type for forward compartment space installed in accordance with 46 CFR 76.27. Waiver may be requested from OCMI by vessel owner, OCMI will make final determination.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 September 2019
Resolution: OCMI approved request for waiver.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 27 August 2019 Resolved
Machinery space boundaries (ceiling, bulkheads) must be lined with noncombustible panels or insulation approved in accordance with 46 CFR 164.009.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: Verified presence of fire boundary lining.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 August 2019 Resolved
Seal bulkhead penetration in way of fuel lines to prevent vapor passage between lazarette and engine room. Engine room is protected by a fixed fire extinguishing system, contents must be prevented from escaping from space after discharge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: Bulkhead sealed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 September 2018 Resolved
ENSURE THE SHAFT IS PULLED, EXAMINED TO BE ADEQUATE, AND THE CUTLASS BEARING IS REPLACED.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 October 2018
Resolved 7 March 2019
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 21 September 2018 Resolved
WOOD ROT IN ABOVE BATTERY ROOM PORT SIDE IN PLYWOOD DECK AND LATERAL DECK BEAM LED TO DELAMINATION OF DECK.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2018
Resolved 7 March 2019
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 21 September 2018 Resolved
WOOD ROT ABOVE THE STARBOARD AFT FUEL TANK HAS CAUSED DELAMINATION OF THE DECK AND COMPROMISED STRUCTURAL INTEGRITY OF VESSEL.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2018
Resolved 7 March 2019
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 21 September 2018 Resolved
THE BOW PULPIT SUSTAINED DAMAGE TO FIBERGLASS. PULPIT HAS CRACKED ALONG ITS LENGTH DUE TO FALLING OFF THE BLOCKS DURING HURRICANE IRMA. BOW RAILING WAS ALSO DAMAGED DURING THIS FALL.04
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2018
Resolved 7 October 2019
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 21 September 2018 Resolved
EPIRB shall display NOAA registration stick and hydrostatic release shall be marked 2 years from installation date (AUG2021).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2019
Resolution: NOAA registration sticker attached to EPIRB.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.