Records from 2016 to 2017. Most recent: inspection, 6 January 2017.
Fire Fighting › Combustible Materials › Insulation
Issued 15 December 2016
Resolved
0750-Fire Prevention-Means shall be provided to control leaks of flammable liquids. Found oil soaked lagging along the sludge pipe, numerous places in the purifier room and oil soaked rags left in drip trays. 74 SOLAS(14)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 December 2016
Resolved 17 December 2016
Resolution: cleaned out drip trays and replaced lagging.
Engineering › Lubricating Oil Storage/Transfer System › Valve
Issued 15 December 2016
Resolved
1499-Other(Aux Machinery)- After any survey of the ship under regs 7,8,9,&10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. Vessel had two valve bonnets that had improper repairs located next to the OWS. 74 SOLAS(14) I/11(b)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 December 2016
Resolved 17 December 2016
Resolution: replaced the valve bonnets and class signed off as them being permanantly repaired.
Engineering › Feedwater/Condensate Water System › Tank
Issued 15 December 2016
Resolved
1499-Other(Aux. Machinery)- After any survey of the ship under Regs 7,8,9,&10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. The boiler hotwell was overfilling and spilling out water. 74 SOLAS(14) I/11(b)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 December 2016
Resolved 17 December 2016
Resolution: valve was installed incorrectly and once it was fixed the overlfow of water stopped.
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 15 December 2016
Resolved
0715-Detection-Fire protection system and fire fighting systems and appliances shall be properly tested and inspected. The vessel did not have the proper equipment to test their flame detectors. 74 SOLAS(14)II-2/14.1.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 January 2017
Resolved 6 January 2017
Resolution: Vessel procured new testing equipment. Submitted proof of equipment.
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 15 December 2016
Resolved
If the vessel's AIS radar, radio navigation receivers, gyro, echo depth sounding device, or primary steering gear stops operating properly, the person directing the movement of the vessel must report to the nearest COTP. Vessels 9 GHz radar was being fixed when CG team arrived to vessel and not mention of inoperable condition on the NOA was given to the CG prior to arrival.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 15 December 2016
Resolution: Corrected prior to CG departing the vessel.