← All vessels
SONGA PUMA
SONGA PUMA is a 2009 freight ship. The Coast Guard has recorded 21 inspections since 2010, most recently in January 2026, along with 13 deficiencies and 9 operational controls.
Records from 2010 to 2026. Most recent: inspection, 21 January 2026.
- Built
- 2009
- Last inspected
- 21 January 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 13 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9399789 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D5YU9
1092803
Flag
LIBERIA
—
Maury page id
psix-1092803
Inspections, by type
…with no type recorded8
Years with a record
6 calendar years (2010–2026)
The 21 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it32901 - Convention (Subpart B), Gross Ton
13452 - Convention (Subpart B), Net Ton
34616 - Dead Weight, Metric Ton
13452 - Convention (Subpart B), Net Ton
34616 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 21
21 January 2026
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8297909
7 January 2026
PSC B · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8289789
16 April 2025
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8112201
22 December 2021
Ballast Water Examination · PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7370019
25 December 2019
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6878802
17 December 2019
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6875118
10 December 2019
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6871144
2 December 2019
PII Safety Exam · ISPS II Exam · COE-Administrative · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6865231
30 November 2019
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6864674
28 November 2019
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6864223
3 April 2019
ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6654866
28 March 2019
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6651445
12 March 2019
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6646530
27 September 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6549758
6 September 2018
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6534292
4 September 2018
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6531258
4 September 2018
Ballast Water Examination · NPV Safety Exam · ISPS III Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6531742
3 May 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6404488
3 May 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6405240
10 September 2010
ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3846924
10 September 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3847092
Deficiency record · 13
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 January 2026
Resolved
FIRE PROTECTION SYSTEMS AND FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE MAINTAINED AND READY FOR USE. PSCO OBSERVED A LEAK IN THE FIRE MAIN IN THE ENGINE ROOM IN VICINITY OF THE DIESEL GENERATOR ROOM.
74 SOLAS (09) II-2/14.1
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 7 January 2026
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 January 2026
Resolved
OIL FUEL LINES SHALL BE ARRANGED FAR APART FROM HOT SURFACES, ELECTRICAL INSTALLATIONS OR OTHER SOURCES OF IGNITION AND SHALL BE SCREENED OR OTHERWISE SUITABLY PROTECTED TO AVOID OIL SPRAY OR OIL LEAKAGE ONTO THE SOURCES OF IGNITION. PSCO OBSERVED ALL MAIN DIESEL GENERATOR FUEL SUPPLY LINE CONNECTION FLANGES WERE MISSING SPRAY SHIELDS.
74 SOLAS (09) II-2/4.2.2.5.3
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 January 2026
Resolved
ELECTRICAL INSTALLATIONS SHALL BE SUCH THAT ELECTRICAL SERVICES ESSENTIAL FOR SAFETY WILL BE ENSURED UNDER VARIOUS EMERGENCY CONDITIONS. PSCO OBSERVED APPROXIMATELY 10 LIGHTING FIXTURES ADJACENT TO THE SUPERSTRUCTURE WITH INOPERABLE LIGHTS.
74SOLAS(04) II-1/40.1.2
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 December 2019
Resolved
The arrangements for securing weathertightness shall ensure that the tightness can be maintained in any sea conditions. PSCO observed rain water intrusion into the engine room from themain engine room skylight. 66 ICLL (88 proto)I/16.4
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 December 2019
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed excessive oil accumulation beneath each of the ships main diesel generators. 74 SOLAS (04) II-2/1.1
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 4 September 2018
Resolved
01 07126 74SOLAS(14 CONS)II-2/4.1.1 16C MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. BROKEN FUEL OIL LINE WAS ON NUMBER 2 GENERATOR WHICH IS REPAIRED, BUT EXCESSIVE FUEL OIL REMAINS IN BILGE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 September 2018
Resolved
02 13108 74SOLAS(14CONS) II-1/26.1 16AC THE MACHINERY, BOILERS AND OTHER PRESSURE VESSELS SHALL BE OF DESIGN AND CONSTRUCTION AND SO INSTALLED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD. NUMBER 2 GENERATOR HAS A SUBSTANTIAL EXHAUST LEAK.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 4 September 2018
Resolved
03 03103 ICLL66/25.2 16AC EFFICIENT GUARD RAILS SHALL BE FITTED TO ALL EXPOSED PARTS OF THE FREEBOARD AND SUPERSTRUCTURE DECKS. WALKWAY ON THE FORWARD STBD SIDE FOR ACCESS TO CONTAINERS HAD A MISSING RAILING ON THE TOP.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 4 September 2018
Resolved
04 14199 33CFR156-170(f)(3) 16C BUNKER LINE TEST FOR VESSELS, MUST BE CONDUCTED ANNUALLY. LAST TEST CONDUCTED 04SEP17 AND VESSEL IS UNABLE TO CONDUCT TEST PRESENTLY.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 3 May 2018
Resolved
0936-STEERING GEAR COMPARTMENTS SHALL BE PROVIDED WITH SUITABLE ARRANGEMENTS THAT SHALL INCLUDE HANDRAILS AND GRATINGS OR OTHER NON-SLIP SURFACES. / STEERING GEAR COMPARTMENT DID NOT HAVE NON-SLIP SURFACE OR GRATING. 74 SOLAS(14) CH II-1/ REG 29.13.2
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 3 May 2018
Resolved
2015- THE MASTER OF A SHIP IN A PORT OF ANOTHER CONTRACTING GOVERNMENT SHALL IMMEDIATLY REPORT ANY SUCH DEFICIENCIES DISCOVERED. / MASTER FAILD TO NOTIFY THE COTP OF A DISPENSATION FOR FIXED FIRE FIGHTING SYSTEM. 74SOLAS (14) CH I / REG11C
Fire Fighting › International Shore Connection › Washers
Issued 3 May 2018
Resolved
0720 - SHIPS OF 500 GT AND UPWARDS SHALL BE PROVIDED WITH AT LEAST ONE INTERNATIONAL SHORE CONNECTION COMPLYING WITH THE FSS CODE. / PSC OFFICERS NOTICED THE ISC WAS MISSING ALL WASHERS AND THE GASKET. 74 SOLAS(14) CH II-2 . REG 10.2.1.7.1
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.