← All vessels
TELENDOS
TELENDOS is a 2010 tank ship. The Coast Guard has recorded 18 inspections since 2010, most recently in November 2018, along with 9 deficiencies and 4 operational controls.
Records from 2010 to 2018. Most recent: operational control imposed, 9 November 2018.
- Built
- 2010
- Last inspected
- 9 November 2018
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9412086 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
SVAP3
1093335
Flag
GREECE
—
Maury page id
psix-1093335
Inspections, by type
…with no type recorded8
Years with a record
6 calendar years (2010–2018)
The 18 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it22971 - Convention (Subpart B), Gross Ton
6891 - Convention (Subpart B), Net Ton
37108 - Displacement, Ton
26634 - Dead Weight, Ton
6891 - Convention (Subpart B), Net Ton
37108 - Displacement, Ton
26634 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 18
9 November 2018
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6578301
3 August 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6518644
6 June 2018
Ballast Water Examination · ISPS II Exam · Deficiency Check · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6436049
10 October 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6285061
10 October 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6285072
15 March 2017
ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6105083
10 February 2016
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5807949
2 February 2016
In-Service Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 5807934
28 June 2014
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4902490
28 June 2014
COE-Dockside
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4902998
24 June 2014
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4898586
7 May 2014
COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4852303
19 September 2011
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4148850
15 September 2011
COC-GAS Annual · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4145409
28 January 2011
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3933772
13 September 2010
Ballast Water Examination · COC-GAS Renew · ISPS I Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3849145
13 September 2010
Type not recorded
No type recorded · Station Pascagoula · USCG Heartland District (CGD-H) · Activity 3850609
9 September 2010
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3845943
Deficiency record · 9
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 15 June 2018
Resolved
The safety management system should ensure compliance with mandatory rules and regulations. The company should establish procedures to ensure the ship is maintained in conformity with the relevant rules and regulations and any additional requirements established by the company. The vessel's COF authorizes .25 BAR "AT SEA" and .45 BAR "IN HARBOR" MARV settings. The vessel was detained after the attending PSC officer discovered that all cargo tank auziliary relief valves were improperly sealed to the pilot relief valves, preventing the proper changing from the cargo tank's "AT SEA" and "IN HARBOR" pressure relief valve settings as required by the COF, SOE and shipboard SMS procedures. Further interviews and statements from the chief officer verified that the relief valves had not been changed since they were last adjusted and pressure tested on 04 February 2015 by Lloyd's Register.
*Based on the seriousness of this deficiency, and external or internal ISM audit is recommended.*
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 15 June 2018
Resolved
A permanently installed system of gas detection with audible and visual alarms shall be provided. Alarms should be activated when the vapor concentration reaches 30% LEL (or earlier). Testing and calibration should be carried out at regular intervals.
When PSC officers requested to test the fixed gas detection, the crew calibrated with 50% LEL propane. The system uses a dilution pump due to a catalytic sensor being used and drawing samples from inerted spaces being monitored for gas concentrations. Due to using a 1:1 ratio of gas sample with the dilution pump, when the gas detection alarm panel reads 25% LEL gas concentration, it is equivilant to 50% LEL. On this ship, LEL alarms are set at 20% LEL (With High-High alarm at 30% LEL). When span gas (50% LEL) was applied to the sample point inside the cabinet, the panel alarmed at 20% LEL and stabilized at 35% LEL. WIth the calibration procedures and calculations needed due to the dilution pump, this alarm set point is equal to 40% LEL gas concentration and does not satisfy the IGC requirements of alarming when the vapor concetration reaches 30% LEL (or earlier). Recommend vessel carry out portable gas sampling with appropratite portrable equipment in accordance with IGC 13.6.12, if concurred with by the recognized organization, until proper alarm set points are able to be set.
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 10 June 2018
Resolved
THE SAFETY MANAGEMENT SYSTEM SHOULD ENSURE COMPLIANCE WITH MANDATORY RULES AND REGULATIONS [ISM 1.2.3.1]. THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THE SHIP IS MAINTAINED IN CONFORMITY WITH THE RELEVANT RULES AND REGULATIONS AND ANY ADDITIONAL REQUIREMENTS ESTABLISHED BY THE COMPANY [ISM 10.1] VESSEL'S COF AUTHORIZES 0.25 BAR “AT SEA” AND 0.45 BAR “IN HARBOR” MARV SETTING IAW IGC 4.2.6.4, 8.2.6.2, AND 8.2.7.
WHILE INSPECTING THE PILOT AND AUXILIARY RELIEF VALVES ON EACH TANK TOP, IT WAS DISCOVERED THAT THE “SET AND SEAL” FOR THE AUXILIARY (IN HARBOR) RELIEF VALVE WAS SECURED TO THE PILOT (AT SEA) RELIEF VALVE, PREVENTING THE TWO FROM BEING SEPARATED WITHOUT REMOVING THE “SET AND SEAL” WIRE OR THE TOP COUPLER FROM THE PILOT (AT SEA) RELIEF VALVE. THE SHIP’S OFFICIAL LOG DID NOT INDICATE THAT THE RELIEF VALVES WERE CHANGED AT EACH PORT VESSEL ENTERED AND DEPARTED. WHILE QUESTIONING THE MASTER AND [name withheld] RELIEF VALVE CHANGE PROCEDURES, THEY EACH STATED THAT THE RELIEF VALVE SETTING IS NEVER CHANGED FROM THEIR “IN HARBOR” SETTINGS WHILE THEY’RE AT SEA AND REQUIRED TO BE AT THE “AT SEA” SETTINGS.
THE VESSEL PROVIDED DOCUMENTATION TO THE ATTENDING PSC EXAMINERS SHOWING THAT THE VESSEL RELIEF VALVES WERE LAST ADJUSTED AND PRESSURE TESTED ON 04 FEBRUARY 2015 BY LLOYD’S REGISTER. SHIPBOARD SMS, CARGO PLANT OPERATING MANUAL, REQUIRES RELIEF VALVES TO BE SET AND SEALED FOLLOWING SATISFACTORY TESTING AND ADJUSTMENTS (DOCUMENT NO. T-0655-N1).
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 10 June 2018
Resolved
GAS DETECTION EQUIPMENT SHOULD BE SO DESIGNED THAT IT MAY READILY BE TESTED. TESTING AND CALIBRATION SHOULD BE CARRIED OUT AT REGULAR INTERVALS. SUITABLE EQUIPMENT AND SPAN GAS FOR THIS PURPOSE SHOULD BE CARRIED ON BOARD.
THE VESSEL ONLY HAD PROCEDURES IN PLACE TO CALIBRATE THE GAS DETECTION SYSTEM WITH NO PROCEDURES IN PLACE OR EQUIPMENT ONBOARD TO TEST THE GAS SAMPLING POINTS. WHEN ASKED TO TEST THE GAS DETECTION FROM A SAMPLING POINT, THE CREW USED AN UNAPPROVED PROPANE TORCH WITH UNKNOWN GAS CONCENTRATION.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 10 June 2018
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Electrical › Lighting (service) › Lighting Fixture
Issued 10 June 2018
Resolved
ELECTRICAL INSTALLATIONS SHOULD BE SUCH AS TO MINIMIZE THE RISK OF FIRE AND EXPLOSION FROM FLAMMABLE PRODUCTS. UPON EXAMINATION OF THE COMPRESSOR ROOM, PSCO IDENTIFIED THE LIGHT OUTSIDE THE COMPRESSOR ROOM DOOR HAD STANDING WATER INSIDE THE GLASS ENCLOSURE. VESSEL IS REQUIRED TO ISOLATE THE LIGHT FROM THE ELECTRICAL CIRCUIT UNTIL REPLACEMENT IS AVAILABLE.
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 10 June 2018
Resolved
THE CHANGING OF THE SET PRESSURE SHOULD BE CARRIED OUT UNDER THE SUPERVISION OF THE MASTER IN ACCORDANCE WITH THE PROCEDURES APPROVED BY THE ADMINISTRATION AND SPECIFIED IN THE OPERATING MANUAL. THE CHANGES IN SET PRESSURES SHOULD BE RECORDED IN THE SHIP’S LOG. THE VESSEL DID NOT INDICATE IN THE SHIP’S LOG THE CHANGING FROM “AT SEA” TO “IN HARBOR” RELIEF VALVE SETTING PRIOR TO CONDUCTING CARGO OPERATIONS.
Lifesaving › Lifeboat › Hull
Issued 2 February 2016
Resolved
STBD lifeboat damaged and inoperable.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 15 September 2011
Resolved
PSCO observed raw water emanating from boiler attachment plate to IGG. Prior to use of IGG demonstrate proper operation of all audible/visual alarms and shutdowns.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.