TELENDOS is a 2010 tank ship. The Coast Guard has recorded 8 inspections since 2016, most recently in November 2018, along with 8 deficiencies and 2 operational controls.

Records from 2016 to 2018. Most recent: operational control imposed, 9 November 2018.

Built
2010
Last inspected
9 November 2018
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9412086
1093335
Flag
GREECE
Maury page id
psix-1093335

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded4
Years with a record 3 calendar years (2016–2018)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it22971 - Convention (Subpart B), Gross Ton
6891 - Convention (Subpart B), Net Ton
37108 - Displacement, Ton
26634 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 8

9 November 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6578301
3 August 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6518644
6 June 2018 Ballast Water Examination · ISPS II Exam · Deficiency Check · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6436049
10 October 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6285061
10 October 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6285072
15 March 2017 ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6105083
10 February 2016 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5807949
2 February 2016 In-Service Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 5807934

Deficiency record · 8

Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 15 June 2018 Resolved
The safety management system should ensure compliance with mandatory rules and regulations. The company should establish procedures to ensure the ship is maintained in conformity with the relevant rules and regulations and any additional requirements established by the company. The vessel's COF authorizes .25 BAR "AT SEA" and .45 BAR "IN HARBOR" MARV settings. The vessel was detained after the attending PSC officer discovered that all cargo tank auziliary relief valves were improperly sealed to the pilot relief valves, preventing the proper changing from the cargo tank's "AT SEA" and "IN HARBOR" pressure relief valve settings as required by the COF, SOE and shipboard SMS procedures. Further interviews and statements from the chief officer verified that the relief valves had not been changed since they were last adjusted and pressure tested on 04 February 2015 by Lloyd's Register. *Based on the seriousness of this deficiency, and external or internal ISM audit is recommended.*
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 August 2018
Resolution: SEC HOU-GAL PSC received an ISM Audit Report from LR satisfying the requirement.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 15 June 2018 Resolved
A permanently installed system of gas detection with audible and visual alarms shall be provided. Alarms should be activated when the vapor concentration reaches 30% LEL (or earlier). Testing and calibration should be carried out at regular intervals. When PSC officers requested to test the fixed gas detection, the crew calibrated with 50% LEL propane. The system uses a dilution pump due to a catalytic sensor being used and drawing samples from inerted spaces being monitored for gas concentrations. Due to using a 1:1 ratio of gas sample with the dilution pump, when the gas detection alarm panel reads 25% LEL gas concentration, it is equivilant to 50% LEL. On this ship, LEL alarms are set at 20% LEL (With High-High alarm at 30% LEL). When span gas (50% LEL) was applied to the sample point inside the cabinet, the panel alarmed at 20% LEL and stabilized at 35% LEL. WIth the calibration procedures and calculations needed due to the dilution pump, this alarm set point is equal to 40% LEL gas concentration and does not satisfy the IGC requirements of alarming when the vapor concetration reaches 30% LEL (or earlier). Recommend vessel carry out portable gas sampling with appropratite portrable equipment in accordance with IGC 13.6.12, if concurred with by the recognized organization, until proper alarm set points are able to be set.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 August 2018
Resolution: Vessel was able to have manufacturer technician attend vessel and provide proper procedures for testing and calibrating equipment. Technician provided training to crew for future testing and calibrating.
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 10 June 2018 Resolved
THE SAFETY MANAGEMENT SYSTEM SHOULD ENSURE COMPLIANCE WITH MANDATORY RULES AND REGULATIONS [ISM 1.2.3.1]. THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THE SHIP IS MAINTAINED IN CONFORMITY WITH THE RELEVANT RULES AND REGULATIONS AND ANY ADDITIONAL REQUIREMENTS ESTABLISHED BY THE COMPANY [ISM 10.1] VESSEL'S COF AUTHORIZES 0.25 BAR “AT SEA” AND 0.45 BAR “IN HARBOR” MARV SETTING IAW IGC 4.2.6.4, 8.2.6.2, AND 8.2.7. WHILE INSPECTING THE PILOT AND AUXILIARY RELIEF VALVES ON EACH TANK TOP, IT WAS DISCOVERED THAT THE “SET AND SEAL” FOR THE AUXILIARY (IN HARBOR) RELIEF VALVE WAS SECURED TO THE PILOT (AT SEA) RELIEF VALVE, PREVENTING THE TWO FROM BEING SEPARATED WITHOUT REMOVING THE “SET AND SEAL” WIRE OR THE TOP COUPLER FROM THE PILOT (AT SEA) RELIEF VALVE. THE SHIP’S OFFICIAL LOG DID NOT INDICATE THAT THE RELIEF VALVES WERE CHANGED AT EACH PORT VESSEL ENTERED AND DEPARTED. WHILE QUESTIONING THE MASTER AND [name withheld] RELIEF VALVE CHANGE PROCEDURES, THEY EACH STATED THAT THE RELIEF VALVE SETTING IS NEVER CHANGED FROM THEIR “IN HARBOR” SETTINGS WHILE THEY’RE AT SEA AND REQUIRED TO BE AT THE “AT SEA” SETTINGS. THE VESSEL PROVIDED DOCUMENTATION TO THE ATTENDING PSC EXAMINERS SHOWING THAT THE VESSEL RELIEF VALVES WERE LAST ADJUSTED AND PRESSURE TESTED ON 04 FEBRUARY 2015 BY LLOYD’S REGISTER. SHIPBOARD SMS, CARGO PLANT OPERATING MANUAL, REQUIRES RELIEF VALVES TO BE SET AND SEALED FOLLOWING SATISFACTORY TESTING AND ADJUSTMENTS (DOCUMENT NO. T-0655-N1).
Action required: 30 - Ship detained
Due 11 June 2018
Resolved 15 June 2018
Resolution: Class attended vessel and approved new company procedures for changing out relief valves after completing an audit. Class also bench tested relief valves onboard the vessel.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 10 June 2018 Resolved
GAS DETECTION EQUIPMENT SHOULD BE SO DESIGNED THAT IT MAY READILY BE TESTED. TESTING AND CALIBRATION SHOULD BE CARRIED OUT AT REGULAR INTERVALS. SUITABLE EQUIPMENT AND SPAN GAS FOR THIS PURPOSE SHOULD BE CARRIED ON BOARD. THE VESSEL ONLY HAD PROCEDURES IN PLACE TO CALIBRATE THE GAS DETECTION SYSTEM WITH NO PROCEDURES IN PLACE OR EQUIPMENT ONBOARD TO TEST THE GAS SAMPLING POINTS. WHEN ASKED TO TEST THE GAS DETECTION FROM A SAMPLING POINT, THE CREW USED AN UNAPPROVED PROPANE TORCH WITH UNKNOWN GAS CONCENTRATION.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 June 2018
Resolution: Company provided proper equipment and written procedures for testing and calibrating fixed gas detection equipment approved by class.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 10 June 2018 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Due 10 June 2018
Resolved 15 June 2018
Resolution: Company provided proper equipment and written procedures for testing and calibrating fixed gas detection equipment approved by class.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 June 2018 Resolved
ELECTRICAL INSTALLATIONS SHOULD BE SUCH AS TO MINIMIZE THE RISK OF FIRE AND EXPLOSION FROM FLAMMABLE PRODUCTS. UPON EXAMINATION OF THE COMPRESSOR ROOM, PSCO IDENTIFIED THE LIGHT OUTSIDE THE COMPRESSOR ROOM DOOR HAD STANDING WATER INSIDE THE GLASS ENCLOSURE. VESSEL IS REQUIRED TO ISOLATE THE LIGHT FROM THE ELECTRICAL CIRCUIT UNTIL REPLACEMENT IS AVAILABLE.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 June 2018
Resolution: Vessel was able to isolate the electrical circuit until a proper light could be installed.
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 10 June 2018 Resolved
THE CHANGING OF THE SET PRESSURE SHOULD BE CARRIED OUT UNDER THE SUPERVISION OF THE MASTER IN ACCORDANCE WITH THE PROCEDURES APPROVED BY THE ADMINISTRATION AND SPECIFIED IN THE OPERATING MANUAL. THE CHANGES IN SET PRESSURES SHOULD BE RECORDED IN THE SHIP’S LOG. THE VESSEL DID NOT INDICATE IN THE SHIP’S LOG THE CHANGING FROM “AT SEA” TO “IN HARBOR” RELIEF VALVE SETTING PRIOR TO CONDUCTING CARGO OPERATIONS.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 June 2018
Resolution: Vessel edited official logbook to reflect new relief valve changes approved by class.
Lifesaving › Lifeboat › Hull
Issued 2 February 2016 Resolved
STBD lifeboat damaged and inoperable.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 February 2016
Resolved 12 February 2016