Records from 2018 to 2025. Most recent: inspection, 10 December 2025.
Documentation record
Registered dimensions (L × B × D)29.0 ft × 12.0 ft × 5.4 ft
Registered tonnagegross 12 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEA HAWK INDUSTRIES INC · SEBRING, FL, UNITED STATES · built 2011
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCHARLESTON, SC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 26 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 12
10 December 2025
Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8281643
23 October 2025
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8257767
30 October 2024
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8026358
8 January 2024
Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7846363
10 August 2023
COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7754637
31 October 2022
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7586839
20 July 2022
Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7507338
2 November 2021
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7343276
29 October 2020
DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7077262
8 July 2020
Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7000599
17 September 2019
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6813833
10 July 2018
COI Inspection · Hull Examination · Simplified Stability Test · Drydock Exam · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6474326
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 October 2024
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy.
Vsl's ring life buoy missing lanyard with corrosion-resistant clip. 46 CFR 180.70(d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2024
Resolved 18 November 2024
Resolution: Received photo of new waterlight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 August 2023
Resolved
Flexible nonmetallic hose may be used in lube oil, fuel oil and fluid power systems installed in lengths of not more than 30 inches. The engine's fuel supply and return flexible nonmetallic hoses were over 30 inches and secured using hose clamps.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 November 2023
Resolved 25 August 2023
Resolution: Hose meets requirements set forth in 182.720, less than 30 inches and properly secured.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 1 November 2022
Resolved
Provision must be made for closing all supply duct cowls or scoops for a space protected by a fixed gas extinguishing system. Vent closures for the machinery space did not adequately secure the openings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2022
Resolved 7 November 2022
Resolution: Operator provided photographs attesting to adequate closures of ventilation to the machinery space. Deficiency rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 November 2022
Resolved
A vessel of more than 7.9 meters in length, but not more than 19.8 meters, must carry a minimum of one life buoy. Ring life buoy on vessel was missing the plug, allowing for the potential for water to enter the ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2022
Resolved 28 November 2022
Resolution: Operator provided photo of new ring life buoy. Deficiency rectified.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 November 2022
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either: (1) A pressure type connector on each conductor; (2) A solder lug on each conductor; (3) A splice made with a pressure type connector to a flexible lead or conductor; or (4) A splice that is soldered, brazed, or welded to a flexible lead or conductor. Multiple exposed wires were identified in forward compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2022
Resolved 7 November 2022
Resolution: Operator provided photographs attesting to adequate repairs made to the wiring. Deficiency rectified.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 November 2022
Resolved
At each inspection for certification all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Electrical cable connected to one of the battery terminals had sheathing that was ripped and exposed wires to the environment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2022
Resolved 7 November 2022
Resolution: Operator provided photographs attesting to adequate repairs made to the wiring. Deficiency rectified.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 1 November 2022
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessel did not have the Emergency Instructions mounted at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2022
Resolved 7 November 2022
Resolution: Operator provided photographs attesting to the correct emergency iinstructions being mounted at the operating station. Deficiency rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 November 2022
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel had two different types of life jackets and no donning placard to match one of the types.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2022
Resolved 9 November 2022
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 November 2022
Resolved
Watertight containers for distress flares shall be marked in legible contrasting letters at least 0.5 in high: “DISTRESS SIGNALS”. Distress Signals was not marked on the watertight container designated for flares
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2022
Resolved 7 November 2022
Resolution: Operator provided photographs attesting to "DISTRESS SIGNALS" marked on watertight container. Deficiency rectified.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 2 November 2021
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. The FCC-licensed technician must use the latest FCC Information Bulletin, How to Conduct an Inspection of a Small Passenger Vessel. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate.
Vessel missing Safety Radiotelephony Certificate for newly purchased VHF-DSC radiotelephone. Vessel restricted to operations within 1000 ft from shore.
47 CFR 80.903
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2021
Resolved 18 November 2021
Resolution: FCC representative issued new Safety Radiotelephony Certificate.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 2 November 2021
Resolved
Except as noted in paragraph (c) of this section, stations in the maritime service must be licensed by the FCC either individually or by fleet.
Vessel held expired Station License. Vessel restricted to operations within 1000 ft from shore.
47 CFR 80.13(a)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2021
Resolved 5 November 2021
Resolution: Recieved copy of new Station License
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 2 November 2021
Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: “DISTRESS SIGNALS”.
Vessel's portable watertight container not labeled with "DISTRESS SIGNALS".
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2021
Resolved 8 November 2021
Resolution: Vessel's portable watertight container labeled as required.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 November 2021
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space.
Vessel missing two portable battery lights.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2021
Resolved 8 November 2021
Resolution: Vessel obtained two portable battery lights.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 November 2021
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16).
Vessel's life buoy contained incorrect retro reflective tape. Correct tape was available and fixed on the spot.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 2 November 2021
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 October 2020
Resolved
Place in service two USCG approved day flares or two USCG approved night flares.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 October 2020
Resolution: New USCG approved flares were purchased and placed in service.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 October 2020
Resolved
Update expired items in first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 October 2020
Resolution: A new USCG approved first aid kit was placed in service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 September 2019
Resolved
Place is service a new USCG approved waterlight that meets the requirements of 46 CFR 160.010 or 160.110.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 October 2019
Resolution: A new, USCG approved waterlight was placed in service.