MAURY USCG vessel records
← All vessels

BANGKOK BRIDGE

BANGKOK BRIDGE is a 2010 freight ship. The Coast Guard has recorded 7 inspections since 2016, most recently in April 2025, along with 2 deficiencies and 1 operational control.

Records from 2016 to 2025. Most recent: inspection, 1 April 2025.

Built
2010
Last inspected
1 April 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 April 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9463279
1095409
Flag
PANAMA
Maury page id
psix-1095409

Documentation record

Tonnage as PSIX records it44234 - Convention (Subpart B), Gross Ton
24146 - Convention (Subpart B), Net Ton
52118 - Dead Weight, Metric Ton
70779 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 7

1 April 2025 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8099394
24 May 2018 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6422254
16 March 2018 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6373852
16 March 2018 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6385347
10 May 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6142883
5 May 2017 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6138725
6 February 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5810640

Deficiency record · 2

Electrical › Electric Generation Source (service) › Generator
Issued 16 March 2018 Resolved
1430 - AUXILIARY ENGINES - ELECTRICAL INSTALLATIONS SHALL BE SUCH THAT ALL ELECTRICAL AUXILIARY SERVICES NECESSARY FOR MAINTAINING THE SHIP IN NORMAL OPERATIONAL AND HABITABLE CONDITIONS WILL BE ENSURED WITHOUT RECOURSE TO THE EMERGENCY SOURCE OF ELECTRICAL POWER. VESSEL EXPERIENCED A LOSS OF POWER WHILE INBOUND TO PORT. 74SOLAS(14) II-1/40.1.1 -60ac-
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 March 2018
Resolution: Survey report states: LO low pressure trip for generators was set at 0.43 MPa rather than 0.35MPa. After changing the setting satisfactory test was carried out in presence of the surveyor.
Electrical › Electric Supply System (service) › Cable
Issued 6 February 2016 Resolved
74SOLAS (2014cons.) CHII-1 Reg. 45.5.5Cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage. Wiring for the oil mist detection system on the main engine is not installed correctly and is not supported from chafing or other damage.40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 March 2016
Resolution: Recieved class report attesting to the repair of oil mist detection system wiring.

Ownership record