This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for ALICE THERESA, retrieved 18 September 2026. mauryrecords.com/v/psix-1095410.html
Documentation record
Tonnage as PSIX records it7902 - Dead Weight, Ton 5706 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Inspection history · 2
3 October 2010Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3862321
22 September 2010Ballast Water Examination · COC-CHEM Renew · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3855046
Engineering › Generator (propulsion/auxiliary-electric) › Auto Transformer Circuitry
Issued 22 September 2010Resolved
1430- Auxiliary engines- Emergency generator shall start automatically upon failure of the main source of electrical power. While conducting pre-arrival E-Gen test, crew discovered that it would not start automatically. Prove proper operation to satisfaction of class. SOLAS2004(Cons)II-1/43.3.1.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2010
Resolution: Class attested to the automatic starting of the emergency generator.
Communications › Internal Communications System › Sound-powered Telephone
Issued 22 September 2010Resolved
9900- Other (Not clearly hazardous)- Appropriate means of communication shall be installed from machinery spaces to the navigation bridge. PSCO discovered sound powered phones are inoperable throughout the vessel. Prove proper operation to satisfaction of class. SOLAS2009(Cons)II-1/37.1
Action required: 705 - Other - as specified
Due 27 October 2010
Resolved 28 September 2010
Resolution: Condition of Class imposed to repair sound-powered phones within 30 days. Temporary comms provided via hand-held communication equipment
Documentation › Manuals/Policy Documentation › Tank Vessel Loading Information
Issued 22 September 2010Resolved
1135- Dangerous Liquid Chemicals in Bulk- Class must provide attestation that vessel meets requirements of 46CFR153.370, 153.371, and 153.438 as required by Chemical Tank Vessel Information Sheet in paragraph II prior to carrying cargos listed in same paragraph. 46CFR153
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2010
Resolution: Class attested that the requirements of 46CFR153.370, 153.371, 153.438 were met.
Deck/Cargo › Inert Gas System › Gas Regulating Valve
Issued 22 September 2010Resolved
0710- Fire Prevention- Suitable means shall be provided for zero and span calibration of the Inert Gas Generator (IGG). During calibration test, vessel crew was unfamiliar with specific calibration procedures. Also, valve for conducting calibration appeared to have been incorrectly installed. Class must attest ship specific instruction and calibration correction. SOLAS2009(Cons)II-2/5.5.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2010
Resolution: Calibration procedure of Oxygen Analyzer was placed in the Inert Gas Room. Officers were familiarized with calibration of 02 zero calibration, and 02 span calibration. This was verified by attending surveyor. Tests carried out satisfactory.