← All vessels
NAV NEHA
NAV NEHA is a 2010 freight ship. The Coast Guard has recorded 12 inspections since 2010, most recently in August 2023, along with 9 deficiencies and 2 operational controls.
Records from 2010 to 2023. Most recent: operational control imposed, 1 August 2023.
- Built
- 2010
- Last inspected
- 1 August 2023
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9563392 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FHI7
1095810
Flag
LIBERIA
—
Maury page id
psix-1095810
Inspections, by type
The 12 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it22409 - Convention (Subpart B), Gross Ton
12013 - Convention (Subpart B), Net Ton
35034 - Dead Weight, Metric Ton
44764 - Displacement, Metric Ton
12013 - Convention (Subpart B), Net Ton
35034 - Dead Weight, Metric Ton
44764 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 12
1 August 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7759518
28 July 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7755015
7 February 2022
PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7391095
9 July 2021
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7250442
1 July 2021
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7241172
20 June 2021
PSC B · Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7230081
17 June 2021
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7228495
9 June 2021
PSC B
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7218785
4 June 2021
Deficiency Check · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7215192
24 December 2016
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6059278
27 December 2011
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4212135
25 September 2010
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3856584
Deficiency record · 9
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 June 2021
Resolved
Maintenance, testing & inspections shall be carried out based on guidelines of organization & in a manner having regard to esnuring the reliability of fire fighting systesm and appliances. Crew stated manual call points are tested monthly but could not provide inspection records. Crew tested two manual call points in ECR but had to unscrew and remove the front plate. Test key did not function properly in accordance with SALWICO CS4000 Instruction Manual. 74SOLAS14 II-2 / 14.2.2.1 50ac
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 20 June 2021
Resolved
The fire protection systems shall be kept in good order so as to ensure their required performance occurs for fire detection and fire alarm systems. Water mist instruction manual & fire control plan require 01 smoke and 01 flame detectors over SSDGs. #1 SSDG had 01 flame and 01 heat detectors in the overhead. Additionally, the workshop smoke detector had a trash bag covering it to prevent smoke detection. 74SOLAS14 II-2 / 14.2.1.1.2 17ac
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 June 2021
Resolved
Before a ship leaves port and at all times during voyage, all lifesaving appliances shall be in working orter and ready for immediate use. PSCO observed steering on the freefall lifeboat inoperable. The steering wheel moved with no rudder action. Repaired by C/E in approximately 15 minutes. Oil was added to the steering mechanism.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 June 2021
Resolved
The purpose of this regulation is to maintain and monitor the effectiveness of fire safety measures the ship is provided with. Fire protection systems and fire fighting appliances shall be maintained ready for use. PSCO observed fire extinguisher in acetylene cage corroded and empty and the fire extinguisher outside the engine control room overcharged. PSCO verified fire control plan. Crew replaced fire extinguishers.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 6 June 2021
Resolved
BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFESAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. THE VESSEL IS LACKING 15/36 IMMERSION SUITS REQUIRED BY ITS CARGO SHIP SAFETY EQUIPMENT CERTIFICATE.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 4 June 2021
Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. 35 out of 36 immersion suits are unserviceable due to unsealed seams. 74 SOLAS (20) III/20.2
14 - Pollution Prevention › 146 - MARPOL Annex VI › Other (MARPOL Annex VI)
Issued 4 June 2021
Resolved
Each incinerator on a ship shall meet the requirements in appendix IV of this Annex. PSCO noticed refractory on incinerator wasted, exposing metal rebar. MARPOL VI/16.6.1
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 4 June 2021
Resolved
The company and the ship shall comply with the requirements of the international Safety Management Code. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations which may be established by the company. 35/36 immersion suits were unserviceable and not noted by the crew during monthly checks. An internal audit of the vessels SMS must be completed within 03 months to the satisfaction of RO and USCG. 74SOLAS(20) IX/3.1, ISM Code A/10.1
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 27 December 2011
Resolved
50C
VGP REQUIRES VESSEL TO SUBMIT A NOTICE OF INTENT TO RECEIVE PERMIT COVERAGE. VESSEL UNABLE TO PROVIDE VGP AND NOI AS PER EPA REQUIREMENTS. 40CFR122 and VGP part 1.5.1 part 10 Appendix ENOI
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.