Records from 2017 to 2020. Most recent: inspection, 4 June 2020.
Inspection history · 4
4 June 2020
PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6956480
26 August 2019
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6788296
12 April 2018
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6382693
6 April 2017
ISPS II Exam · PII Safety Exam · Administrative Inspection · Ballast Water Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6115032
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 26 August 2019
Resolved
EACH VESSSEL MUST HAVE MARINE CHARTS OF THE AREA TO BE TRANSITED THAT ARE CURRENTLY CORRECTED. VESSEL IS UNABLE TO RECIEVE ECDIS UPDATES DUE TO INTERNET CONNECTIVITY AND IS USING PAPER CHARTS THAT ARE NOT CURRENTLY CORRECTED.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2019
Resolution: Vessel updated ECDIS and paper charts.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 12 April 2018
Resolved
0750- Fire Prevention- Means shall be provided to control leaks of flammable liquids. PSCO observed excessive FO leaking IWO of 02 FO strainers on the FO purification flat. SOLAS 74a (2014) II-2/4.1.1 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2018
Resolved 14 April 2018
Resolution: Received class report from NKK stating deficiency have been rectified. The class report stated: All flanges in the area were thoroughly retightened.
Engineering › Fuel Oil Storage/Transfer System › Flange
Issued 12 April 2018
Resolved
1470- Insulation wetted through (oil)- Means shall be provided to control leaks of flammable liquids. PSCO observed excessive FO leaking IWO incinerator sludge tank flanges onto tank top, tank insulation holed and saturated with FO. SOLAS 74a (2009) II-2/4.1.1 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2018
Resolved 14 April 2018
Resolution: Received class report from NKK stating deficiency have been rectified. The class report stated:Tank insulation, saturated with FO, was removed and replaced with new one. Tinplate was restored to original condition to complete tank top repairs.
Fire Fighting › Self-contained Breathing Apparatus › Facepiece
Issued 12 April 2018
Resolved
0699- (other) Life Saving Appliances)- On all ships, within the machinery spaces, EEBD shall be situated ready for use at easily visible places, which can be reached quickly and easily at any time in the event of fire. PSCO observed 02 EEBD that were empty. EEBDs were lasted serviced 31MAR18, no weekly checks had been conducted since placed into service. SOLAS 74a (2014) II-2/13.4.3 MSC/Circ 850 10c
Action required: 10 - Deficiency Rectified
Due 12 April 2018
Resolved 14 April 2018
Resolution: Received class report from NKK stating deficiency have been rectified. The class report stated:
Engineering › Steam System (auxiliary) › Valve
Issued 12 April 2018
Resolved
1499- Other (Prop. & Aux. Machinery)- Every steam boiler and every unfired steam generator shall be provided with not less than two safety valves of adequate capacity. PSCO observed 01 boiler pressure relief valves block from manual release due to incorrect instillation position. SOLAS 74a (2009) II-2/32.1 16a
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2018
Resolved 14 April 2018
Resolution: Received class report from NKK stating deficiency have been rectified. The class report stated: Valve manual release lever was re-positioned. Valve tested satisfactory.