Records from 2010 to 2026. Most recent: inspection, 16 March 2026.
Documentation record
Registered dimensions (L × B × D)263.2 ft × 54.0 ft × 15.0 ft
Registered tonnagegross 1,741 / net 898
ITC dimensions (L × B × D)263.2 ft × 54.0 ft × 15.0 ft
ITC tonnagegross 1,741 / net 898
BuilderTRINITY MARINE PRODUCTS INC · MADISONVILLE, LA, UNITED STATES · built 2010
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portPORTLAND, OR
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 19 February 2026 · expires 31 March 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1741 - Convention (Subpart B), Gross Ton
898 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 29
16 March 2026
Drydock Exam · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8327073
6 March 2026
Administrative Inspection · Vessel Attendance
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8324818
5 March 2026
Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8313021
19 August 2025
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8148137
7 August 2024
Periodic Inspection · MTSA/ISPS Verification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7932568
28 May 2024
Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7905586
17 July 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7715809
13 July 2022
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7440937
9 July 2021
COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7255982
3 June 2021
Drydock Exam · Load Line/Change of Employment
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7214801
14 May 2021
Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7197027
5 August 2020
Periodic Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7024814
28 June 2019
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6699444
13 June 2018
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6408084
16 January 2018
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6338694
6 October 2017
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6288926
11 July 2017
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6208168
30 November 2016
Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6050107
31 August 2016
Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5988985
8 March 2016
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5829606
8 March 2016
COI Inspection · Drydock Exam · Hull Examination · Cargo Tank Internal · Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5829643
22 October 2015
Internal Structural Exam · COI Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5748881
15 October 2015
Hull Examination · Drydock Extension · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5743481
14 January 2015
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5062916
10 December 2013
Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4766259
24 January 2012
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4263540
5 October 2011
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4162313
19 August 2011
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4121006
1 December 2010
Administrative Inspection · Construction Oversight · Hull Examination · MTSA Verification · Initial Certification · Cargo Tank Internal
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3902043
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 July 2023
Resolved
Shutoff valves shall be installed in the fuel supply lines, as close to each tank as practicable, and one as close to each fuel pump as practicable. Valves shall be accessible at all times. Only one valve exists between the tank and fuel pump for the generator. The one valve in the system is close to the fuel pump. System is missing valve that is required to be as close to the tank as practicable.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 July 2023
Resolution: Received photographic evidence of fuel shutoff valve being installed close to the tank.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 July 2021
Resolved
Provide valid Load line certificate by ABS Class.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2021
Resolved 8 August 2021
Resolution: def cleared
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 July 2021
Resolved
Provide Stability letter
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2021
Resolved 1 August 2021
Resolution: def cleared
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 July 2021
Resolved
Replace Ring Buoy light as identified
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2021
Resolved 1 August 2021
Resolution: def cleared
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 9 July 2021
Resolved
Replace missing studs on 4 hatch covers as identified.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2021
Resolved 1 August 2021
Resolution: Def cleared
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 28 June 2019
Resolved
Gauging sight glasses 1 port, 5 port and 2 stbd were not serviceable. Repair or replace the sight glasses to demonstrate proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2019
Resolved 19 July 2019
Resolution: Verified proper operation of all sight glass.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 11 July 2017
Resolved
Provide adequate means of draining condensate from low points on vapor line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 September 2017
Resolved 10 September 2017
Resolution: Vsl rep called, member cleared def. casework was never completed.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 11 July 2017
Resolved
Review hazardous locations drawing and make corrections as necessary to account for fuel drains around generator house.
Condition: Placed in Improper Service
Due 10 September 2017
Resolved 6 October 2017
Resolution: Plans are satisfactory with drains and is currently under review for alterations.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 July 2017
Resolved
Remove water light on ring buoy on forward ring buoy.
Condition: Improper Installation
Due 11 July 2017
Resolved 11 July 2017
Resolution: Removed water light from buoy.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 October 2015
Resolved
Paint navigation light stands matt black in accordance with 33 CFR 84 (Inland Rules, Annex I).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 October 2015
Resolved 22 October 2015
Resolution: Corrected during inspection.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 24 January 2012
Resolved
Draft marks and loadline both need to be repainted.
Due 9 March 2012
Resolved 29 February 2012
Resolution: Draft marks and loadline painted