Records from 2020 to 2022. Most recent: operational control imposed, 8 June 2022.
Inspection history · 10
8 June 2022
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7471851
6 June 2022
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7470125
2 June 2022
Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7466553
28 May 2022
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7461113
26 May 2022
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7459555
15 July 2020
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7007269
23 June 2020
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6978101
20 June 2020
COE-Administrative
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6981808
19 June 2020
Type not recorded
No type recorded · Station Dauphin Island · USCG Heartland District (CGD-H) · Activity 6981144
16 June 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6978376
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 23 June 2020
Resolved
The carriage of solid bulk cargoes other than grain shall be in compliance with the relevant provisions of the IMSBC. The ship shall be suitably fitted and carry on board approrpriate instruments for measuring the following without requiring entry in the cargo space: concentrations of methane in the atmosphere. Vessel did not have an instrument on board to measure methane gas.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 6 July 2020
Resolution: PSC NOLA received a class report from LR satisfying the requirement.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 23 June 2020
Resolved
All hatchways in position 1 and 2 shall be fitted with hatch covers of steel or other equivalent material. Except as provided in regulation 14(2), such covers shall be weathertight and fitted with gaskets and clamping devices. One (01) hatch covers next to the CO2 room was missing dogs to secure the door.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 6 July 2020
Resolution: PSC NOLA received a class report from LR satisfying the requirement.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 23 June 2020
Resolved
Ventilator openings shall be provided with weathertight closing appliances of steel or other equivalent material. PSCO noted deterioration of closing mechanisms on the following ventilators: paint locker, void space starboard side, pump room, forecastle ventilation, and CO2 room ventilation
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2020
Resolved 6 July 2020
Resolution: PSC NOLA received a class report from LR satisfying the requirement.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo ports and other similar openings
Issued 23 June 2020
Resolved
Bulk carriers shall comply with the maintenance requirements provided in regulation II-1/3-1 and the Standards for owners' inspection and maintenance of bulk carrier hatch covers, adopted by the Organization by resolution MSC.169(79). PSCO noted that the clamping devices and check valves for hatch sealing are not being maintained in accordance with MSC.169(79).
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 6 July 2020
Resolution: PSC NOLA received a class report from LR satisfying the requirement.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 23 June 2020
Resolved
The transfer procedures required by 33 CFR 155.720 must contain either in the order listed or by use of a cross-reference index page: A description of and procedures for emptying the discarge containment as required by 33 CFR 155.310 and 33 CFR 155.320. PSCO noted muptiple containement areas for oil were missing mechanical means of closure.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 6 July 2020
Resolution: PSC NOLA received a class report from LR satisfying the requirement.