MAURY USCG vessel records Sign in
← All vessels

ALMA ATA

ALMA ATA is a 1999 freight ship. The Coast Guard has recorded 27 inspections since 2000, most recently in February 2011, along with 17 deficiencies and 11 operational controls, 1 with no removal date recorded.

Records from 2000 to 2011. Most recent: operational control imposed, 27 February 2011.

Built
1999
Last inspected
27 February 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

8513132 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
TURKEY
—
Maury page id
psix-1096

Inspections, by type

…with no type recorded17
Years with a record 8 calendar years (2000–2011)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it76009 - Dead Weight, Ton
43286 - Regulatory (Subpart C or D), Gross Ton
24874 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 27

27 February 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3953372
23 February 2011 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3951886
22 February 2011 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3944323
22 February 2011 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3944324
28 January 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3137875
24 January 2008 ISPS II Exam · Ballast Water Examination · PII Safety Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3132797
22 January 2008 ISPS I Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3135873
22 January 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3136613
18 January 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3133015
21 July 2005 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2430775
18 July 2005 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2430767
14 July 2005 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2430824
21 May 2005 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2363874
18 May 2005 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2361532
27 May 2004 Re-Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2079516
25 May 2004 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2078162
8 April 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2043033
5 November 2003 Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1938449
4 November 2003 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1942187
18 February 2003 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1745884
5 February 2003 Administrative Inspection · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1740155
22 April 2002 Annual Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1604485
6 December 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 296127
23 February 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 287512
3 October 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 282785
3 October 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 282837
2 February 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 274338

Deficiency record · 17

Electrical › Lighting (service) › Ground Detection
Issued 22 February 2011 Resolved
There was a ground detected on the 220v feeder pannel in the emergency generator room, it was found that the ground was caused by faulty wiring in the engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 February 2011
Resolution: Received class report attesting to satisfactory repair to wiring in engine room lighting system.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 22 February 2011 Resolved
The class "A" door leading to the engine room on the starboard side could not be closed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 February 2011
Resolution: Received class report attesting to satisfactory repair of class "A" fire door.
Deck/Cargo › Holds/Tanks
Issued 10 November 2003 Resolved
Starboard side #2 hatch coaming was damaged by a crane during cargo operations. LEGACY COMPONENT DESC: Coaming
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2003
Resolution: Repairs were completed to the satisfaction of the ABS class surveyor. Vessel fit for service. Class faxed report documenting same was received on 12Nov03.
Lifesaving › Inflatable Liferafts
Issued 5 November 2003 Resolved
Three hydrostatic release units on port and starboard liferafts were found in questionable condition by CG boarding officer. Require replacement of these three releases prior to departure from port. LEGACY COMPONENT DESC: Hydrostatic Release Unit
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2003
Resolution: Replacements were verified to have been placed onboard by attending CG boarding officer.
Lifesaving › Lifebuoys
Issued 5 November 2003 Resolved
Two starboard side lifebouy lights were found inoperable. Replace two lights prior to departure. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2003
Resolution: Two replacement lights were verified to have been put into service by attending CG boarding officer.
Engineering › Steering Gear System
Issued 5 November 2003 Resolved
Hydraulic seal on #1 steering gear found leaking. LEGACY COMPONENT DESC: Hydraulic Hose
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 December 2003
Resolved 12 November 2003
Resolution: Received fax from class stating repairs complete and no further leakage.
Engineering › Freshwater Generation System
Issued 5 February 2003 Resolved
CEMENT PATCH ON SEAWATER FEED PIPE ON FRESHWATER GENERATOR. REPAIR/RENEW TO THE LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 March 2003
Resolved 1 August 2003
Resolution: Vessel went into drydock through the month of July03. Vessel was surveyed by class at end of drydock period and was found fit for sea. DF cleared.
Lifesaving › Rescue Boat
Issued 29 April 2002 Resolved
PROVE PROPER OPERATION OF RESCUE BOAT STARTING SYSTEM AND STEERING SYSTEM TO THE SATISFACTION OF ADMINISTRATION LEGACY COMPONENT DESC: Propulsion Starting System, Rudder/Tiller/Steering
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 April 2002
Resolved 1 May 2002
Resolution: REPAIRED TO THE SATISFACTION OF ABS
Lifesaving › Lifeboat
Issued 29 April 2002 Resolved
REPAIR CHARGE CABLE FOR PORT LIFEBOAT BATTERIES LEGACY COMPONENT DESC: CHARGE CABLE FOR LIFEBOAT BATTERIES
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 29 April 2002
Resolved 1 May 2002
Resolution: REPAIRED TO THE SATISFACTION OF ABS
Lifesaving › Lifeboat Equipment
Issued 29 April 2002 Resolved
MAKE REPAIRSTO STBD LIFEBOAT CHARGING/BATTERY SYSTEM. LEGACY COMPONENT DESC: CHARGING/BATTERIES
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 May 2002
Resolved 1 May 2002
Resolution: REPAIRED TO SATISFACTION ABS
Navigation › Piloting/Steering
Issued 29 April 2002 Resolved
PROVIDE CURRENT COPY OF LIGHTLIST. FAX RECIEPT TO USCG ACTIVITIES BALTIMORE PRIOR TO DEPARTURE LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 29 April 2002
Resolved 30 April 2002
Resolution: PROVIDED RECIEPT OF PURCHASE OF COPY OF CURRENT LIGHT LIST VOLUME J
Documentation › Certificates/Documents
Issued 29 April 2002 Resolved
FAX COPY OF NEW DOCUMENT OF COMPLIANCE TO USCG ACTIVITIES BALTIMORE LEGACY COMPONENT DESC: Document of Compliance (ISM)
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2002
Resolved 30 April 2002
Resolution: FAXED COPY OF NEW DOCUMENT OF COMPLIANCE TO ACTIVITIES BALTIMORE
Documentation
Issued 23 February 2001 Resolved
Vessel not manned in accordance with its safe manning document. Only one deck watch officer with GMDSS (Required 2) and no radio officer present. (Required if not manned with 2 GMDSS officers)
Condition: Unknown
Due 23 February 2001
Resolved 9 March 2001
Engineering
Issued 23 February 2001 Resolved
#1 & #3 F/O PURIFIER LEAKING. REPAIR TO SATISFACTION OF CLASS.
Condition: Unknown
Due 28 February 2001
Resolved 13 March 2001
Construction/Loadline
Issued 23 February 2001 Resolved
EXCESSIVE OIL IN BILGES.
Condition: Unknown
Due 28 February 2001
Resolved 13 March 2001
Electrical
Issued 23 February 2001 Resolved
EMERGENCY GENERATOR FUEL OIL LINE LEAKING. REPAIR TO THE SATISFACTION OF CLASS.
Condition: Unknown
Due 28 February 2001
Resolved 13 March 2001
Navigation
Issued 23 February 2001 Resolved
NUMBER 2 STEERING PUMP HAS NUMEROUS LEAKS. REPAIR TO THE SATISFACTION OF CLASS.
Condition: Unknown
Due 26 February 2001
Resolved 13 March 2001

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.