MAURY USCG vessel records
← All vessels

STOLT SISTO

STOLT SISTO is a 2010 tank ship. The Coast Guard has recorded 11 inspections since 2016, most recently in July 2024, along with 4 deficiencies and 1 operational control.

Records from 2016 to 2024. Most recent: inspection, 2 July 2024.

Built
2010
Last inspected
2 July 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 July 2024
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9359375
1096352
Flag
CAYMAN ISLANDS
Maury page id
psix-1096352

Documentation record

Tonnage as PSIX records it26329 - Convention (Subpart B), Gross Ton
14416 - Convention (Subpart B), Net Ton
57235 - Displacement, Ton
46011 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 11

2 July 2024 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7947163
19 March 2024 PSC B · Deficiency Check · Administrative Inspection · COC-CHEM & TVE Renew
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7881174
12 December 2022 COC-CHEM & TVE Annual · Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7603634
3 February 2022 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7390415
15 January 2022 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7379095
14 September 2020 Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7058282
31 May 2019 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6699133
4 May 2018 Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6403283
25 July 2017 ISPS II Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6220037
4 May 2017 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6134440
1 July 2016 Ballast Water Examination · COC-CHEM Annual · ISPS II Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 5923373

Deficiency record · 4

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 March 2024 Resolved
In tankers, electrical equipment, cables, and wiring shall not be installed in hazardous locations unless it conforms with the standards not inferior to the organization. Electrical conduit boxes at Frames 85/86, 57/58, and 53/54 found with conduits wasted through exposing wiring. Holes present a pathway for hazardous vapours to travel into the house/accommodation space. COC Not issued. 74 SOLAS (20) II-1/45.11
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 19 March 2024
Resolved 20 April 2024
Resolution: Received Class Report demonstrating full repair with new steel.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 19 March 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all aspects will remain fit to proceed to sea without danger to the ship or persons on board. Upper walkway and work area between port and stbd manifolds, mid ship, found with severe wastage in structural support members. Supporting flanges and webs found disintegrated and/or fractured due to significant corrosion. See the following specific locations. Frames 76, 77, 78, steam line support beam upper flange wasted through. Frames 55/56 through 61, raised walkway/work area supporting longitudinal and transverse members wasted through. 08 columns at frames 45, 53, 56, 57, 58 (painted by crew) holed through due to wastage. Deck longitudinal between frames 58/59 found "paper thin." 74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 March 2024
Resolved 20 April 2024
Resolution: Received Class Report demonstrating full repair with new steel.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 March 2024 Resolved
Flammable liquid lockers shall be protected by an appropriate fire extinguishing arrangement approved by the administration. PSCO observed 18 boxes of flammable liquid stored in the "rope storage room." Crew moved flammable liquid to chemical storage area. 74 SOLAS (04) II-2/10.6.3.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 March 2024
Resolved 19 March 2024
Resolution: corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 14 September 2020 Resolved
For tankers of 20,000 tonnes deadweight and upwards, the protection of the cargo tanks shall be achieved by a fixed inert gas system in accordance with the requirements of the fire safety systems code. Oxygen analyzer on Nitrogen gernerator plant A would not calibrate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2020
Resolved 16 September 2020
Resolution: received reviewed and accepted

Ownership record