← All vessels
ASPEN ARROW
ASPEN ARROW is a 2010 freight ship. The Coast Guard has recorded 11 inspections since 2011, most recently in February 2026, along with 12 deficiencies and 1 operational control.
Records from 2011 to 2026. Most recent: inspection, 10 February 2026.
- Built
- 2010
- Last inspected
- 10 February 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 12 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9423566 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C6GS3
1096745
Flag
BAHAMAS, THE
—
Maury page id
psix-1096745
Inspections, by type
…with no type recorded1
Years with a record
6 calendar years (2011–2026)
The 11 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it35240 - Convention (Subpart B), Gross Ton
16425 - Convention (Subpart B), Net Ton
53021 - Dead Weight, Metric Ton
67065 - Displacement, Metric Ton
16425 - Convention (Subpart B), Net Ton
53021 - Dead Weight, Metric Ton
67065 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 11
10 February 2026
PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8308558
14 February 2025
PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8074309
12 September 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7557299
4 April 2022
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7423989
10 February 2022
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7393998
7 February 2022
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7388867
1 February 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7389113
13 February 2020
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6908735
27 March 2019
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6650705
26 March 2019
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6649442
18 August 2011
PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4114125
Deficiency record · 12
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 April 2022
Resolved
Cylinders must always be secured and, when not in use, they must be stowed in a rack in an upright position, with the valve protection cap in place. PSCO observed oxygen and acetylene cylinders not in use stowed without caps on them and lashed together on the deck not in a rack.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 4 April 2022
Resolved
Cargo ships shalll carry at least one rescue boat complying with the requirements of section 5.1 of the code. PSCO observed crew retrieve fire extinguisher and all rescue boat items from a remote location; required rescue boat equipment was not stowed inside the rescue boat.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 7 February 2022
Resolved
In meeting these requirements, the company should ensure that any non-conformity is reported, with its possible cause, if known. PSCO noted the vessel failed to report several non-conformities, per vessel's Safety Management System (SMS) procedures, of a technical and operational nature which collectively provide objective evidence of a serious failure or lack of effectiveness of the implementation of the ISM Code. Due to the failure or lack of effectiveness of the SMS, an external SMS audit shall be carried out.
74SOLAS (20) IX/3.1
ISM CODE A/10.2
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 February 2022
Resolved
Oil fuel pipes, which, if damaged, would allow oil to escape from a storage settling or daily service tank having a capacity of 500L and above shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occuring in the space in which such tanks are situated. PSCO observed inoperable quick closing valve on LS Settling tank #1 and two bolts were wedged in place to prevent valve from closing.
74 SOLAS(20)II-2/4.2.2.3.4
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 February 2022
Resolved
The following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. PSCO observed a leak in the port side bunkering line where fuel leaked onto a ventilation trunk on port side upper level of engine room.
74 SOLAS(20) II-2/4.1.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 February 2022
Resolved
The condition of the ship and equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed significant leaking of the main engine jacket water regulating valve.
74 SOLAS(20) I/11
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 February 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed excessive leaking from overhead piping on port side lower level of engine room where vessel crew had set up arrangements to protect electrical equipment and motors from leak.
74 SOLAS (20) I/11
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 7 February 2022
Resolved
Guard rails or bulwarks shall be fitted around all exposed decks. PSCO observed safety chain for pilot embarkation point held together with wire.
ICLL(88)I/25(2)
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 7 February 2022
Resolved
The following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. PSCO observed engine room bilge was excessively dirty and requires flammable liquids to be removed.
74 SOLAS(20)II/4.1.1
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 7 February 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed non approved equipment installation where a blower was suspended to provide additional ventilation forward, mid-level of main engine.
74 SOLAS (20) I/11
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 April 2019
Resolved
13199 - Other (machinery) - The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. All three ship's generators have active oil leaks. No. 2 generator has a continuous leak from the cooler at the front of the generator. - 74 SOLAS (04) II-I/26.1 - 16ac
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 5 April 2019
Resolved
11102 - Lifeboat inventory - The normal equipment of every lifeboat shall consist of: a food ration totalling not less than 10,000kJ for each person the lifeboat is permitted to accommodate. 05 of the required 26 food rations were damaged. Ship's crew was able to restock rations from ship's safety store. 74 SOLAS (14) III/34, LSA CODE 4.4.8.12 - 10c
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.