Records from 2010 to 2025. Most recent: inspection, 26 December 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
26 December 2025
Administrative Inspection · PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8287072
18 August 2024
PSC B
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7983733
24 January 2023
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7626392
20 January 2023
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7621058
20 January 2023
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7624300
4 August 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7277100
31 January 2021
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7133556
10 May 2019
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6676114
17 April 2018
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6393649
12 April 2018
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6391918
9 April 2018
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6383279
7 April 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6119541
10 May 2016
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5873231
6 April 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5847034
1 April 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5845167
7 November 2015
COE-Dockside
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5755041
18 September 2015
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5722645
22 September 2011
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4151425
27 October 2010
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3878657
Fire Fighting › Structural - A Class Divisions › Doors
Issued 9 April 2018
Resolved
The penetrations in structural fire protection divisions shall be kept in good order so as to ensure their required performance. Self-closing mechanisms on ladderwell class A doors to cargo decks 7, 8, and 10 were missing or malfunctioning. Required on fire control plan.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2018
Resolution: Recieved Class report attesting to the repair of the fire doors.
Documentation › Logs/Records › Oil Record Book
Issued 1 April 2016
Resolved
1710: Every ship 400 GT and above shall be provided with an Oil Record Book. Dates and signatures missing from the Oil Record Book since Novermber 2015. Marpol Annex I Reg 17.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 6 April 2016
Resolution: Discussed with Captain and Chief Engineer.
Documentation › Safety/Response Plans/Programs › Ballast Water Management Plan
Issued 1 April 2016
Resolved
2510: See Narrative Section
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 6 April 2016
Resolved 10 May 2016
Resolution: Addressed and corrected to the satisfaction of the attending Classification Representative.
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 1 April 2016
Resolved
0750: The function of the fire detection system shall be periodically tested by means of appropriate equipment. Crew did not have adequate means of testing the flame detector. Tests were being conducted using an open flame. 74 SOLAS (14) II-2/7.3.2.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 6 April 2016
Resolution: Discussed with [name withheld], and Chief Engineer.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 1 April 2016
Resolved
1705: Vessel's Shipboard Oil Pollution Emergency Plan shall be prepared based on guidelines developed by the organization. The ship's SOPEP didn't contain the POC for the local authorities. The plan was in disarray and not setup in accordance with the table of content. Vessels nontank vessel response plan is in disarray and doesn't follow table of contents. Marpol Annex I Reg 37 & 33 CFR 155.5030
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 6 April 2016
Resolution: Discussed with Captain and Chief Engineer.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 1 April 2016
Resolved
2120: Every ship 400 GT and above shall carry a Garbage Management Plan which the crew shall follow. The garbage log is missing disposition and quantities of garbage incinerated and/or disposed of ashore. Mixed garbage found throughout vessel. Marpol Annex V Reg 9.2.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 6 April 2016
Resolution: Discussed with [name withheld], and Chief Engineer.
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 1 April 2016
Resolved
2420: Those ships using seperate fuel oils and entering or leaving and emission control area shall carry written procedures showing how the fuel oil change over is to be done. Vessel does not have change over procedures approved by the company. Marpol Annex III Reg 14.6.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 6 April 2016
Resolution: Discussed with Captain and Chief Engineer.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 1 April 2016
Resolved
0900: The machinery, pressure vessels, associated piping systems, and fittings shall be of a design and construction for the service for which they are intended. Incinerator has a 5 cm crack on upper right corner of the lower chamber.74 SOLAS (14) II-1/26.1.
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Due 6 April 2016
Resolved 10 May 2016
Resolution: Addressed and corrected to the satisfaction of the attending Classification Representative
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.1-Routine Visual Inspections
Issued 1 April 2016
Resolved
2510: VGP records of routine visual inspections shall be kept. Vessel is not following VGP requirements. VGP Part 4.1.1, 4.1.1.1, 4.1.3, and 4.2.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 6 April 2016
Resolution: Discussed with [name withheld], and Chief Engineer.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 1 April 2016
Resolved
0999: Cylinders must always be secured and when not in use they must be stowed in a rack in an upright position with the valve protection cap in place. Oxygen, acetylene, and R404 bottles throughout the vessel are not secure and several bottles are missing protection caps. 46 CFR 147.60(b).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 6 April 2016
Resolution: Discussed with [name withheld], and Chief Engineer.
Lifesaving › Lifeboat Equipment › Water/Water Receptacles
Issued 27 October 2010
Resolved
0611 - Lifeboat Inventory - Lifeboats required to have 3L of fresh water for each person the lifeboat is permitted to accomodate. Lifeboats accomodate 25 persons equating to 75L of fresh water. Lifeboats only contained 30L of fresh water. SOLAS 74 (09) Ch. III, Reg 13.1.4; LSA Code Ch. IV 4.4.8.9
Action required: 705 - Other - as specified
Due 27 October 2010
Resolved 27 October 2010
Resolution: Deficiency corrected on the spot. Vessel obtained sufficient amount of fresh water for each lifeboat.