← All vessels
MAERSK COLUMBUS
Freight Ship · General Dry Cargo Ship class · USCG East District (CGD-E) · Other hulls named MAERSK COLUMBUS
MAERSK COLUMBUS is a freight ship. The Coast Guard has recorded 92 inspections since 2014, most recently in June 2026, along with 54 deficiencies, 10 operational controls, 1 with no removal date recorded and 11 casualty investigations between 2013 and 2026.
Records from 2013 to 2026. Most recent: inspection, 8 June 2026.
- Built
- Not recorded
- Last inspected
- 8 June 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 54 recorded · 0 without a recorded resolution
- Controls
- 1 with no removal date recorded
- Casualties
- 11 investigations · 2013–2026
Identity
1245603
9332987 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WMCU
1097100
Flag
UNITED STATES
338525000
Maury page id
psix-1097100
Inspections, by type
…with no type recorded30
Years with a record
13 calendar years (2014–2026)
The 92 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Registered dimensions (L × B × D)943.2 ft × 131.2 ft × 66.6 ft
Registered tonnagegross 74,642 / net 44,243
ITC dimensions (L × B × D)943.2 ft × 131.2 ft × 66.6 ft
ITC tonnagegross 74,642 / net 44,243
BuilderHANJIN HEAVY IND & CONSTRUCTION CO. LTD · KOREA, REPUBLIC OF
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNORFOLK, VA
Trade endorsementsRegistry, Canadian bulk freight
DocumentationValid · issued 7 August 2026 · expires 30 September 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it74642 - Convention (Subpart B), Gross Ton
44243 - Convention (Subpart B), Net Ton
84704 - Dead Weight, Ton
44243 - Convention (Subpart B), Net Ton
84704 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WMCUMMSI 338525000 · active · compulsorily equipped · granted 4 January 2023, expires 22 March 2033
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 92
8 June 2026
Annual Inspection · MSP Select Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8395169
22 May 2026
Explosive Handling Operation-Commercial
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8378386
31 March 2026
Explosive Handling Operation-Commercial
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8338784
28 January 2026
Administrative Inspection
Administrative · Activities Europe · Activity 8302706
27 January 2026
Type not recorded
No type recorded · Activities Europe · Activity 8306502
15 December 2025
Explosive Handling Operation-Commercial
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8283909
8 December 2025
Administrative Inspection
Administrative · Activities Europe · Activity 8278893
17 November 2025
Explosive Handling Operation-Commercial
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8267378
10 October 2025
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8250505
9 October 2025
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8250272
6 September 2025
Administrative Inspection
Administrative · Activities Europe · Activity 8228225
2 August 2025
Administrative Inspection
Administrative · Activities Europe · Activity 8200487
1 August 2025
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8215597
14 July 2025
Administrative Inspection · MSP Annual Oversight · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8185833
8 January 2025
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8060407
5 December 2024
Administrative Inspection
Administrative · Activities Europe · Activity 8043492
18 August 2024
Administrative Inspection
Administrative · Activities Europe · Activity 7983705
5 July 2024
MSP Annual Oversight · MTSA/ISPS Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7949665
12 December 2023
Administrative Inspection
Administrative · Activities Europe · Activity 7838041
9 November 2023
Administrative Inspection
Administrative · Activities Europe · Activity 7822415
20 October 2023
Administrative Inspection · Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7811689
13 October 2023
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7811798
29 September 2023
Type not recorded
No type recorded · Activities Europe · Activity 7804544
22 September 2023
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7796375
25 July 2023
Deficiency Check · MSP Annual Oversight · Annual Inspection · MSP Select Additional Oversight – Risk Assessment
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7744851
20 June 2023
Administrative Inspection
Administrative · Activities Europe · Activity 7719666
18 June 2023
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8068959
26 May 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7696954
19 May 2023
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7692259
6 April 2023
Administrative Inspection
Administrative · Activities Europe · Activity 7664415
9 March 2023
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7648077
27 February 2023
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7643279
22 February 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7640389
24 January 2023
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7626461
24 December 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7612770
8 December 2022
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7606461
6 December 2022
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7657338
30 November 2022
Ballast Water Examination · MSP Select Additional Oversight – Risk Assessment
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7601927
9 October 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7574900
9 October 2022
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7576631
6 October 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7572626
8 September 2022
Administrative Inspection
Administrative · Activities Europe · Activity 7554825
19 June 2022
Type not recorded
No type recorded · Activities Europe · Activity 7484779
14 March 2022
MSP COI Oversight · COI Inspection · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 7411177
19 February 2022
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7398910
11 June 2021
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7222631
21 May 2021
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7274841
2 April 2021
MSP Annual Oversight · Annual Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7165706
7 January 2021
MSP Select Additional Oversight – Risk Assessment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7120808
7 January 2021
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7120848
31 October 2020
Administrative Inspection · In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7087632
17 August 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7035372
27 May 2020
MSP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6961619
25 February 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6915425
21 February 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6912969
2 February 2020
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6901283
11 October 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6842303
16 April 2019
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6663319
19 March 2019
Type not recorded
No type recorded · Activities Europe · Activity 6658641
6 February 2019
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6627991
4 February 2019
MSP COI Oversight · Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6619570
4 September 2018
MSP Select Additional Oversight – Risk Assessment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6531979
15 June 2018
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6445177
10 April 2018
MSP COI Oversight · MTSA/ISPS Verification · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6384772
9 February 2018
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6378617
5 February 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6349527
1 February 2018
MSP Select Additional Oversight – Risk Assessment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6347563
1 February 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6347892
2 January 2018
Type not recorded
No type recorded · Activities Europe · Activity 6339636
20 November 2017
MSP Select Additional Oversight – Risk Assessment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6309852
2 August 2017
In-Service Inspection
Physical examination · Activities Europe · Activity 6228028
27 July 2017
Type not recorded
No type recorded · Activities Europe · Activity 6232764
22 June 2017
Annual Inspection · MSP Annual Oversight · MTSA/ISPS Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6188385
3 February 2017
Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Activities Europe · Activity 6072603
6 January 2017
ISM Oversight
Administrative · Activities Europe · Activity 6067848
9 December 2016
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6055190
9 December 2016
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6137154
1 December 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6050788
18 October 2016
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6024672
8 July 2016
MTSA/ISPS Verification · MARPOL Annex VI Survey · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5931707
8 February 2016
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5811399
8 February 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5813816
5 February 2016
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5810260
4 February 2016
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5809628
1 February 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5807730
29 January 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5806371
16 November 2015
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5764452
13 November 2015
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5763138
16 June 2014
Type not recorded
No type recorded · Activities Europe · Activity 4959373
29 May 2014
In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4873049
29 May 2014
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4873195
29 May 2014
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4873372
Deficiency record · 54
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 6 September 2025
Resolved
At all times during a vessels voyage, all life-saving appliances shall be in working order and ready for immediate use. Vessel reported the rescue boat engine starter was discovered to be inoperable during routine checks. New part is on order and will arrive at vessel's next port of call in Antwerp, Belgium on 11Sep2025. Rectification is contingent upon successful installation and in person survey by class.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 July 2024
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use.
02 life-rafts were found to have the hydrostatic release
mechanism installed improperly rendering the float free
arrangement inoperable.
Hydro statics were removed and correctly installed. Def
cleared by USCG.
74SOLAS(2020) III/20.2
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 5 July 2024
Resolved
Instructions for on-board maintenance of life-saving
appliances shall be easily understood, illustrated
wherever possible, and, as appropriate shall include for
each appliance: log for records and maintenance.
Rescue boat was found to have unauthorized repairs done
to the underside of the rescue boat where it rests in
the cradle. There are no records of the when the repair
was conducted or approval from Class.
74SOLAS(2020) III/36.7
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 July 2024
Resolved
The machinery, boilers, and other pressure vessels,
associated piping systems and fittings shall be of a
design and construction adequate for the service for
which they are intended and shall be so installed and
protected as to reduce to a minimum any danger to
persons on board, due regard being paid to moving parts,
hot surfaces, and other hazards.
MI identified a leaking pressure regulating valve that
supplies fuel to the MDE located the in the purifier
room.
74SOLAS(04) II-1/26
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Shore - Ship
Issued 22 September 2023
Resolved
For all ships the means of embarkation and disembarkation shall be inspected and maintained in suitable condition for their intended purpose. Vessel self-reported damage to stbd accommodation ladder. Effect permanent repairs or replacement to satisfaction of RO. Flag Dispensation is granted to the vessel MAERSK COLUMBUS until 20 November 2023.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 25 July 2023
Resolved
Fire protection appliances shall be maintained ready for use, a fire extinguisher in the reefer deck workshop was blocked and not ready for immediate use. The area was immediately cleared.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 25 July 2023
Resolved
A duplicate set of fire control plans or a booklet containing such plans shall be permanently stored in a prominently marked weather-tight enclosure outside the deck-house for the assistance of shore-side fire-fighting personnel. The fire plan in the enclosures were revision #04 when there is a newer revision on-board. Ensure that all fire control plans on-board are of the most current revision.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 July 2023
Resolved
The machinery and associated fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts. The turbo return valves are leaking oil on the #1 & #3 generators make proper repairs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 July 2023
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Vessel is missing High Voltage safety equipment. Provide the proper high voltage personal equipment.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 25 July 2023
Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. As per the vessel's safety management system, there are over 50 maintenance items that are overdue. Maintenance needs to be completed to the satisfaction of the Recognized Organization, American Bureau of Shipping.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 July 2023
Resolved
Measures shall be taken to ensure that the equipment is functioning in a reliable manner and that satisfactory arrangements are made for regular inspections and routine tests to ensure continuous reliable operation. Found that the on-board Periodic Safety Test Procures not being fully tested nor is there any recording/log of when the tests when conducted. To the satisfaction of the Recognized Organization Lloyd’s Register of Shipping, ensure the testing and recording are done in a way to ensure that the there is evidence that the tests are being conducted.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 26 May 2023
Resolved
Whenever a vessel is deprived of the service of a member of its complement, and the master or person in charge is unable to find appropriate credentialed personnel to man the vessel MAERSK COLUMBUS a report of sailing short must be filed with the OCMI having cognizance for inspection in the area in which the vessel is operating, or the OCMI within whose jurisdiction the voyage is completed. Vessel master/rep made sailing short notification for the position of Able Seaman from Newark, NJ to Algeciras, Spain. 46 CFR 15.725
09 - Working and Living Conditions › 092 - Working Conditions › Adequate lighting - mooring arrangements
Issued 6 December 2022
Resolved
Whenever defect is discovered, the master or owner of the ship shall report at the earliest opportunity to the Administration or Recognized Organization (RO). Back in 2020 the vessel reported to the operator of a clutch issue (not aligned) to the port side anchor windless, but never reported it to the Administration or RO. In addition the vessel just came out of dry-dock in June 2022 with the clutch not aligned, there were also several anchor chain links and chain stopper pins, that were known to be bent but not repair or replaced while in the dry-dock.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 22 March 2022
Resolved
Falls used in launching shall be inspected periodically with special regard for areas passing through sheaves, and renewed when necessary due to deterioration of the falls or at intervals of not more than 5 years, whichever is the earlier. Falls for both port and starboard lifeboats were due to be replaced by 03JAN2022. Replace both sets of falls by the end of the next scheduled drydock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 March 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Several non-metallic expansion joints on the #1, #2, and #3 service diesel generators were found cracking.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 22 March 2022
Resolved
Load Line and draft marks: The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. The marks shall be plainly visible and, if necessary, special arrangements shall be made for this purpose. Load line and draft marks were not visible on the port side of the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 March 2022
Resolved
Hoses specified in this chapter as "fire hoses" shall, together with any necessary fittings and tools, be kept ready for use in conspicuous positions near the water service hydrants or connections. One hose on starboard side main deck had leaks on both ends, replace with new hose.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 March 2022
Resolved
Waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. Large waste receptacle on the bridge is made of combustible material.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 March 2022
Resolved
It shall be the duty of the owner, master, or person in charge to require and have performed as least once in every twelve months the tests and inspections of all hand portable fire extinguishers, semiportable fire extinguishing systems, and fixed fire extinguishing systems on board. Portable fire extinguishers were required to be serviced by 03 February 2022 and were not.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 14 March 2022
Resolved
Every vessel equipped with a radio installation on an international voyage must have a Cargo Ship Safety Radio Certificate. Each radio installation must meet the requirements of the Federal Communication Commission and the International Convention for Safety of Life at Sea. Vessel did not have a valid Cargo Ship Safety Radio Certificate on board.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 14 March 2022
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a
design and construction adequate for the service for which they are intended and shall be so installed and
protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts,
hot surfaces and other hazards. Fuel piping on all generators was found with missing and damaged lagging.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 2 April 2021
Resolved
The main steering gear and rudder stock shall be capable of moving the rudder over from 35 degrees on one side to 35 degrees on the other side. Steering pump #4 limited to 30 degrees to 30 degrees
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 2 April 2021
Resolved
A certificate called a Cargo Ship Safety Radio certificate shall be issued after an initial or renewal survey to a cargo ship which complies with the relevant requirements of Chapter IV and any other relevant requirements of the present regulations. The Cargo Ship Radio Certificate does not match the EPIRB registration number.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 2 April 2021
Resolved
A discharge of oil or oily mixture during the operation of the ship in excess of the quantities or instantaneous rate permitted in 151.10 or this subpart in 157.37 of this subchapter. Containment coaming found wasted port and starboard main deck.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 2 April 2021
Resolved
An alarm system shall be provided indicating any fault requiring attention and shall be capable of sounding an audible alarm in the main machinery control room or at the propulsion machinery control position, and indicate visually each separate alarm function at a suitable position. The low combustion air for the boiler was inoperative. Perform all auxiliary boiler automatic control tests, (check point 13.0-13.1) IAW approved vital system automation periodic safety test procedures in the prescence of the attending class surveyor.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 April 2021
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handles or touched in a normal maanner. Unapproved installation for 480 volt power in non-electrical container bays powering reefer units.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 2 April 2021
Resolved
Stairways and ladders shall be so arranged as to provide ready means of escape to the lifeboat and liferaft embarkation deck from passenger or crew accommodation spaces and from spaces in which the crew is normally employed other than machinery spaces. Leader leading to the Focsle was found wasted.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 2 April 2021
Resolved
The ship's name, call sign, official number, IMO international number, and principal characteristics. The ship's name and information was incorrect on the SOPEP.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 2 February 2020
Resolved
Every ship engaged in voyages in sea areas beyond sea areas A1 & A2, but remaining in sea area A3 shall be provided with radio installations and equiment required by Reg 10. MF/HF radio installation was found to be inop during annual maint. The vsl is authorized to sail until such time as repairs can be made by a qualified technician. SOLAS IV/10
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 February 2019
Resolved
Fire door between E/R and ECR self closure and hinge is malfunctioning.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 7 February 2019
Resolved
Rescue boat search light was inoperable.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 February 2019
Resolved
Fire detection head in purifier room was inopperable.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 4 February 2019
Resolved
Rescue boat is missing prop guard required by 4.4.6.7 of the LSA Code
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 4 September 2018
Resolved
One of the vessel's radar telescoping poles has 4 stays
securing to the deck above the bridge by means of a welded pad eye connection which is wasted completely
away and not connected allowing for this radar to move excessively, Second radar pole has three connections and one is wasted, must repair to new condition as designed.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 4 September 2018
Resolved
One VHF antenna on the port aft bridge wing area is mounted by duct tape, must repair this to manufacture instructions and/or like new condition.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 4 September 2018
Resolved
STBD lifeboat drum for both the fwd and aft falls is showing signs of being wasted and the steel is d-laminating, this could eventually cause the falls line to jump off the drum during operation; must prepare a permanent solution for repair to the satisfaction of the attending class society.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 4 September 2018
Resolved
Vessel's cover to the port P/A connection on the exterior bridge wing is being held in place with electrical tape, this must be fixed to correct new condition.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 5 February 2018
Resolved
The electrical storeroom on the navigation bridge has a wire penetration through a “A” Class boundary on the forward bulkhead in way of the door. Properly run wires through penetrations. Structural fire protection including fire-resisting divisions and protection of openings and penetrations in these divisions shall be kept in good order to ensure their required performance if a fire occurs. To be cleared by the satisfaction of the attending Authorized Classification Surveyor no later than 05 March 2018. SOLAS 74/78 Chapter II-2 Reg 14 2.1.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 5 February 2018
Resolved
The electrical storeroom on the navigation bridge has a wire penetration through a “A” Class boundary on the forward bulkhead in way of the door. Properly run wires through penetrations. Structural fire protection including fire-resisting divisions and protection of openings and penetrations in these divisions shall be kept in good order to ensure their required performance if a fire occurs. To be cleared by the satisfaction of the attending Authorized Classification Surveyor no later than 05 March 2018. SOLAS 74/78 Chapter II-2 Reg 14 2.1.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 5 February 2018
Resolved
Fuel shut off for the emergency generator was not easily assessable, as door had to be pried open, in addition there is nothing identifying where the pull cable is located. Properly label the emergency fuel shut off on exterior aft bulkhead of emergency generator, so it is easily identified in case of an emergency. Oil fuel pipes….or daily service tank….shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space in which such tanks are situated. To be cleared by the satisfaction of the attending Authorized Classification Surveyor no later than 05 March 2018. SOLAS 74/78 Chapter II-2 Reg 4.2.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 5 February 2018
Resolved
Air supply dampener, starboard side for the emergency generator not able to open/closed manual in case the air supply is loss of control air, all sheaves and fittings are painted over. Free up all fittings and demonstrate proper operation of dampener without control air. The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. To be cleared by the satisfaction of the attending Authorized Classification Surveyor no later than 05 March 2018. SOLAS 74/78 Chapter I Part B Reg 11
Fire Fighting › Structural - A Class Divisions › Special Category Spaces
Issued 5 February 2018
Resolved
(Corrected while onboard) The electrical storeroom on the navigation bridge was being used as a storeroom (buckets, mobs, toilet paper, rock and salt coffee). By using it as a storeroom this changes the space category and does not meet the Fire Safety Objectives of SOLAS 74/78 II-2 Reg 2.1. All items had been removed while onboard.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 5 February 2018
Resolved
The elevator inspection report had expired on 8/1/2017. Vessel had tried several times to get the elevator inspected serviced however the company keeps delaying the inspection. The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. To be cleared by the satisfaction of the attending Authorized Classification Surveyor no later than 05 March 2018. SOLAS 74/78 Chapter I Part B Reg 11
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 5 February 2018
Resolved
Vent/fire damper cut off handle safety pin for galley is rusted and frozen in place and is not easily removed in case of emergency. Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. Demonstrate proper operation of the pin and damper closure. To be cleared by the satisfaction of the attending Authorized Classification Surveyor no later than 05 March 2018. SOLAS 74/78 Chapter II-2 Reg 14.1
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 February 2018
Resolved
Replace the fuel line lagging which is worn in the starboard cargo tunnel. The condition of the ship and its equipment shall be maintained. To be cleared by the satisfaction of the attending Authorized Classification Surveyor no later than 05 March 2018. SOLAS 74/78 Chapter I Reg 11
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 5 February 2018
Resolved
Mechanical fitting (plug) for the containment under the fuel oil vent starboard side IWO hatch 37 is missing. Provide a mechanical fitting. Ensure the discharge containment required by §§ 154.530, 155.310, and 155.320 of this chapter, as applicable are in place. . To be cleared by the satisfaction of the attending Authorized Classification Surveyor or USCG no later than 05 March 2018. 33CFR155.320 33CFR156.120 (n) / MARPOL Annex I
Electrical › Electric Supply System (service) › Cable
Issued 5 February 2018
Resolved
Windless control is hanging by cables. All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Properly mount windless control. To be cleared by the satisfaction of the attending Authorized Classification Surveyor no later than 05 March 2018. SOLAS 74/78 Chapter II-1 Reg 45 1.3
Electrical › Lighting (service) › Lighting Fixture
Issued 5 February 2018
Resolved
The emergency light on the port side bow is hanging by lanyards and zip ties. All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Properly mount the light. To be cleared by the satisfaction of the attending Authorized Classification Surveyor no later than 05 March 2018. SOLAS 74/78 Chapter II-1 Reg 45 1.3
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 5 February 2018
Resolved
Cable penetration found on D&F decks not properly ran through boundaries. Properly run wires through penetrations. Structural fire protection including fire-resisting divisions and protection of openings and penetrations in these divisions shall be kept in good order to ensure their required performance if a fire occurs. To be cleared by the satisfaction of the attending Authorized Classification Surveyor no later than 05 March 2018. SOLAS 74/78 Chapter II-2 Reg 14 2.1
Operations/Management › Drills/Instruction › Fire
Issued 5 February 2018
Resolved
Due to a 60% crew change out USCG was not able to witness a proper frill drill and confine space extraction drill. Prior to depart the next US port the vessel must contact OCMI to attended vessel to wittiness a satisfactory fire and confine space extraction drill. Sector Charleston [phone withheld] or [phone withheld]. In addition, if possible launch operate and recover the port lifeboat and rescue boat in water. Starboard boat were already done.
Stability › Watertight Integrity › General
Issued 22 June 2017
Resolved
WTD gaskets in way of portside upper deck to house and CO2 room WTD entrance are damaged; replaced
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 22 June 2017
Resolved
Strip plug for 110v washers unacceptable for marine application. Permanently rewire machines to good marine practice.
Navigation › Collision/Grounding Avoidance › Radar
Issued 8 February 2016
Resolved
10 CM Radar was reported to be not working; issued inbound LOD to make Permanent repairs prior to departing Sector Houston.
Electrical › Electric Generation Source (emergency) › Panelboard
Issued 29 May 2014
Resolved
#1 generator had tripped off line and the emergency diesel generator started however it did not assume the load. Demonstrate the following in presence of a Marine Inspector and a Surveyor from your Classification (LR); 1) Operation of ship service generators on load singled up and paralleled. 2) Demonstrate automatic start up and assuming the load of the emergency diesel generator.
Casualty record · 11
12 December 2013Routine · role: Involved in a Marine Casualty · activity 4768867
29 May 2014Routine · role: Involved in a Marine Casualty · activity 4873372
9 December 2016Routine · role: Involved in a Marine Casualty · activity 6137154
27 July 2017Routine · role: Involved in a Marine Casualty · activity 6232764
2 January 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6339636
19 March 2019Routine · role: Involved in a Marine Casualty · 1 injured · activity 6658641
21 May 2021Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7274841
19 June 2022Routine · role: Involved in a Marine Casualty · 1 dead · activity 7484779
27 February 2023Routine · role: Involved in a Marine Casualty · activity 7643279
29 September 2023Routine · role: Involved in a Marine Casualty · activity 7804544
27 January 2026Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 8306502
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.