← All vessels
COFFEE
Freight Ship · General Dry Cargo Ship class · Built 2000s · USCG Southeast District (CGD-SE) · Other hulls named COFFEE
COFFEE is a 2008 freight ship. The Coast Guard has recorded 22 inspections since 2012, most recently in February 2026, along with 9 deficiencies and 5 operational controls.
Records from 2012 to 2026. Most recent: inspection, 13 February 2026.
- Built
- 2008
- Last inspected
- 13 February 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9383285 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
A8SB7
1097104
Flag
LIBERIA
—
Maury page id
psix-1097104
Inspections, by type
…with no type recorded7
Years with a record
11 calendar years (2012–2026)
The 22 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it9948 - Convention (Subpart B), Gross Ton
5020 - Convention (Subpart B), Net Ton
13997 - Dead Weight, Metric Ton
5020 - Convention (Subpart B), Net Ton
13997 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 22
13 February 2026
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8310004
11 June 2025
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8156335
7 September 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7998183
27 December 2023
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7842514
4 January 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7616276
8 June 2022
Ballast Water Examination · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7471672
17 February 2022
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7395825
16 February 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7397216
25 November 2020
PSC B · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7101224
27 June 2019
Deficiency Check · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6727093
15 May 2019
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6684598
2 April 2019
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6654265
27 February 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6633213
13 February 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6624926
30 January 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6617239
21 March 2018
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6375816
24 May 2017
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6154291
5 May 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6139450
16 March 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6103572
25 February 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5821680
5 February 2012
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4234409
5 February 2012
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4242346
Deficiency record · 9
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 8 June 2022
Resolved
DOORS AND DOOR FRAMES IN "A" CLASS DIVISIONS SHALL BE CONSTRUCTED OF STEEL. PSCO'S OBSERVED A PENETRATION THROUGH A BROKEN LOCKING MECHANISM WHICH WOULD ALLOW FOR THE PASSAGE OF BOTH SMOKE AND FLAMES THROUGH THE PAINT LOCKER DOOR.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 25 November 2020
Resolved
All life saving appliances and arrangements shall comply with the applicable requirements of the code. the limit switch was preventing the davit from raising the rescue boat with the crew manually raising it. crew replaced the wire, and conducted a satifactory test. 74 SOLAS(14) III/34 LSA CODE 6.1.1.3
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 27 June 2019
Resolved
BEFORE THE SHIP LEAVES PORTAND AT ALL TIMES DURING THE VOYAGE ALL LIFESAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. PSCOS OBSERVED THAT THE RESCUE BOAT DAVIT IS UNABLOE TO OPERATE DUE TO INSUFFICIENT PRESSURE WITHIN THE ACCUMULATOR. ACCUMULATOR IS ONLY REACHING 100 OF 200 BAR. 74 SOLAS (14 CONS) III/20.2
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 24 May 2017
Resolved
MARPOL (2011 cons) Annex I/14.6 - Oil filtering equipment shall be of a design approved by the administration and shall be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15ppm. Vessel oily water seperator inoperable.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 16 March 2017
Resolved
0750-Fire Prevention - Doors required to be self-closing shall not be fitted with hold-back hooks. Fire door to galley opening is fitted with a hold back hook and is not fitted with a self closing mechanism as per fire control plan. 74 SOLAS (14 Cons) CH II-2/REG 9.4.2.2
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 16 March 2017
Resolved
0730- Appliances (General) Fire fighting systems and appliances shall be maintained ready for use. Suction gauge for emergency fire pump is inoperable. Additionally, the flex hose on CO2 cylinder located outside paint locker is cracked, exposing steel fibers. 74 SOLAS (14 Cons) CH II-2/Reg 14.1.1
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 25 February 2016
Resolved
The safety management system should ensure compliance with mandatory rules and regulations. A valve controlling lube oil flow from the MDE to cooler was tied open.
Documentation › Logs/Records › Oil Record Book
Issued 5 February 2012
Resolved
Many entries made in the Oil Record Book Part I did not match oiler sounding records, three OWS usages exceeded throughput value listed on IOPP, and soundings at the incinerator waste oil tank were not being recorded.
73/78 MARPOL ANNEX I/17.2.3,4
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 5 February 2012
Resolved
Vessel did not have an approved manual for the installed Oil Content Meter, and crew members were unable to review previous oil content information.
73/78 MARPOL ANNEX I/31.4
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.