MAURY USCG vessel records
← All vessels

GREEN PIONEER

GREEN PIONEER is a 2010 tank ship. The Coast Guard has recorded 17 inspections since 2016, most recently in May 2026, along with 3 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 12 May 2026.

Built
2010
Last inspected
12 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9471018
1097130
Flag
PANAMA
Maury page id
psix-1097130

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded2
Years with a record 9 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it37108 - Displacement, Metric Ton
22977 - Convention (Subpart B), Gross Ton
6893 - Convention (Subpart B), Net Ton
26599 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 17

12 May 2026 PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8361356
6 March 2023 COC-GAS Annual · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7641412
26 April 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7438490
17 March 2022 PSC B · COC-GAS Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7413502
30 April 2021 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7186452
24 June 2020 COC-GAS Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6981771
21 March 2020 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6929906
5 July 2019 COC-GAS Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6713251
5 July 2019 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6742542
3 April 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6655236
3 April 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6655245
19 February 2019 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6628003
29 July 2018 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6493776
2 July 2018 Ballast Water Examination · Deficiency Check · ISPS II Exam · COC-GAS Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6457579
18 February 2018 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6357180
25 September 2017 Ballast Water Examination · ISPS II Exam · COC-GAS Annual
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6224940
15 July 2016 Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5936824

Deficiency record · 3

08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 March 2022 Resolved
A gas carrier shall comply with the requirements of the IGC Code. An audible and visual alarm system to give warning on both sides of teh airlock should be provided to indicate if more than one door is moved from the closed position. Electrical motor room air lock doors did not alarm locally due to the malfunctioning alarm unit.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 April 2022
Resolution: Class report received attesting to the rectification of the noted deficiency.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 2 July 2018 Resolved
1870 - Tankers-Special Requirements - water spray system on ships carrying flammable or toxic products or both, a water spray system for cooling, fire prevention and crew protection should be installed to cover: exposed cargo tanks; when testing deck water spray there was little to no water flow on both port & stbd tpye C deck tanks and No.#1 FWD tank dome did not have adequate coverage - 74SOLAS(14) VII/13.1 & IGC(93) 11.3.1.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2018
Resolution: Vessel tested deck water spray; Test Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 2 July 2018 Resolved
0610 - Lifeboats - Chemical tankers & gas carriers carrying cargoes emitting toxic vapors or gases shall carry, in lieu of totally enclosed lifeboats complying with the requirements of section 4.6 of the code, lifeboats with a self contained air support complying with the requirements of section 4.8 of the code. The STBD lifeboat's compressed air line failed during testing of the system. The hoses began popping and relieving air throughout the hose - 74SOLAS(14) III/31.1.6
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 July 2018
Resolution: Stbd lifeboat air supply hose renewed and tested with satisfactory pressure.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.