Records from 2017 to 2023. Most recent: inspection, 5 July 2023.
Inspection history · 5
5 July 2023
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7733909
22 February 2023
PSC B · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7634734
11 October 2021
PSC B · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7323706
30 September 2021
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7323952
3 April 2017
Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6116535
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 22 February 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea with out danger to ship or or persons on board. Port side anchor chain has broken chain stud and multiple chain links with studs have a gap greater than 3in.
74SOLAS(14)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 July 2023
Resolution: Tech report showed weld repair. Class approval was also provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 22 February 2023
Resolved
The load line shall be painted in white or yellow on a dark background or in black on a light background. Port side load line paint chipped and corroded.
ICLL I/8
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 July 2023
Resolution: Vessel provided tech report and pictures of painted load lines.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 February 2023
Resolved
In tankers, electrical equipment, cables and wiring shall not be in hazardous locations unless it conforms with standards not inferior to those acceptable to the Organization. Water ballast pump #2 casing temp sensor has exposed wiring.
74SOLAS(14)II-1/45.11
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 February 2023
Resolved 22 February 2023
Resolution: Temp sensor cabling replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 February 2023
Resolved
In tankers, electrical equipment, cables and wiring shall not be in hazardous locations unless it conforms with standards not inferior to those acceptable to the Organization. Intrinsically safe and explosion proof light fixture lens cracked.
74SOLAS(14)II-1/45.11
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 22 February 2023
Resolved 22 February 2023
Resolution: Lens replaced.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 October 2021
Resolved
STAIRWAYS AND LIFT TRUNKS WHICH PENETRATE MORE THAN A SINGLE DECK SHALL BE SURROUNDED BY AT LEAST "A-0" CLASS DIVISIONS AND BE PROTECTED BY SELF-CLOSING DOORS AT ALL LEVELS. FIRE DOORS FOR THE DUMB WAITER ON "A" DECK IN GALLEY AND SUNKEN DECK DRY PROVISIONS STORE ROOM WERE NOT FITTED WITH SELF-CLOSING DEVICES. SELF-CLOSING DEVICES ARE REQUIRED BY THE VESSEL'S APPROVED FIRE CONTROL PLAN AND BY THIS REGULATION.
74 SOLAS (20) II-2/9.2.3.4.1
Action required: 17 - Rectify deficiencies prior to departure
Due 11 October 2021
Resolved 12 October 2021
Resolution: Reviewed class report attesting to the installation of self-closing devices on the fire doors for the dumb waiter at both levels.