MAURY USCG vessel records
← All vessels

AMPHITRITE

AMPHITRITE is a 2010 tank ship. The Coast Guard has recorded 9 inspections since 2016, most recently in February 2024, along with 2 deficiencies.

Records from 2016 to 2024. Most recent: inspection, 20 February 2024.

Built
2010
Last inspected
20 February 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 February 2024
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9455973
9HA4033
1097472
Flag
MALTA
Maury page id
psix-1097472

Documentation record

Tonnage as PSIX records it162203 - Convention (Subpart B), Gross Ton
112192 - Convention (Subpart B), Net Ton
320137 - Dead Weight, Metric Ton
364076 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

9 inspections, each with its date, unit and type; 2 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 9

20 February 2024 PSC B · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7860072
18 July 2019 COE-Administrative
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6754247
13 September 2018 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6539808
13 September 2018 NPV Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6540018
6 September 2018 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6525795
18 February 2018 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6352802
23 May 2017 ISPS II Exam · Ballast Water Examination · COC-TVE Annual · COE-Offshore
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6147895
13 January 2017 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6070534
23 May 2016 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5872908

Deficiency record · 2

07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 6 September 2018 Resolved
CODE: 07102 CITE: 74SOLAS(14)II-2/4.5.5.3.2 FSS CODE 15.2.3.1.6.1 ACTION: 60(a)(c) THE INERT GAS SYSTEM SHALL BE DESIGNED, CONSTRUCTED AND TESTED IN ACCORDANCE WITH THE FIRE SAFETY SYSTEMS CODE. SPECIAL CONSIDERATION SHALL BE GIVEN TO THE DESIGN AND LOCATION OF SCRUBBER AND BLOWERS WITH RELEVANT PIPING AND FITTINGS IN ORDER TO PREVENT THE FLUE GAS FROM LEAKAGES INTO ENCLOSED SPACES. BLOWERS #2 AND #3 WERE LEAKING INERT GAS INTO THE SPACE.
Action required: 60 - Rectify deficiencies prior to movement
Due 6 September 2018
Resolved 6 September 2018
Resolution: Received class report attesting to repair.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 6 September 2018 Resolved
CODE: 04114 CITE: 74SOLAS(14)II-1/43.3.3 ACTION 10(c) WHERE THE EMERGENCY SOURCE OF ELECTRICAL POWER IS A GENERATOR, IT SHALL BE: CAPABLE OF BEING AUTOMATICALLY STARTED AND SUPPLYING THE REQUIRED LOAD AS QUICKLY AS IS SAFE AND PRACTICABLE SUBJECT TO A AMAXIMUM OF 45 S. EMERGENCY GENERATOR TOOK 119 SECONDS TO SUPPLY THE REQUIRED LOAD. CREW ADJUSTED TIMER ON EMERGENCY GENERATOR AND REDUCED THE TIME REQUIRED TO SUPPLY EMERGENCY LOAD TO UNDER 45 SECONDS.
Action required: 10 - Deficiency Rectified
Due 6 September 2018
Resolved 6 September 2018
Resolution: CREW ADJUSTED TIMER ON EMERGENCY GENERATOR AND REDUCED THE TIME REQUIRED TO SUPPLY EMERGENCY LOAD TO UNDER 45 SECONDS.