This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it33044 - Simplified, Gross Ton 33044 - Convention (Subpart B), Gross Ton 19231 - Convention (Subpart B), Net Ton 19231 - Simplified, Net Ton 57021 - Dead Weight, Metric Ton 67681 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 2
7 December 2021PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7357274
27 November 2021Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7357965
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 January 2022Resolved
A fixed fire-extinguishing system required by paragraph 5 below may be any of the following systems: Afixed gas fire-extinguishing system complying with the provisions of the Fire Safety Systems Code.
The Piping for the distributuion of fire-extinguishing medium shall be arranged and discharge nozzles so positioned that a uniform distribution of the medium is obtained. PSCO observed 01 discharge nozzle in engine room clogged.
74SOLAS(09) II-2/4.1.1.1
FSS CODE 5.2.1.2.1
Action required: 10 - Deficiency Rectified
Resolved 14 January 2022
Resolution: PSCO Verified crew cleaned fixed fire extinguishing system nozzle.
Duct keels and ventilators shall be of the same strength as watertight bulkheads at corresponding levels. PSCO observed forward Duct keel hatch unable to secure properly.
Action required: 10 - Deficiency Rectified
Resolved 14 January 2022
Resolution: PSCO observed adjustment and proper latching of the forward Duct keel hatch.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National