MAURY USCG vessel records
← All vessels

MAERSK SARATOGA

MAERSK SARATOGA is a freight ship. The Coast Guard has recorded 34 inspections since 2016, most recently in February 2026, along with 51 deficiencies and 1 casualty investigation in 2022.

Records from 2016 to 2026. Most recent: inspection, 8 February 2026.

Built
Not recorded
Last inspected
8 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 February 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9289207
1098058
Flag
UNITED STATES
Maury page id
psix-1098058

Documentation record

Registered dimensions (L × B × D)607.8 ft × 105.6 ft × 55.4 ft
Registered tonnagegross 24,488 / net 10,441
ITC dimensions (L × B × D)607.8 ft × 105.6 ft × 55.4 ft
ITC tonnagegross 24,488 / net 10,441
BuilderVOLKSWERFT GMBH STRALSUND · Stralsund, GERMANY
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNORFOLK, VA
Trade endorsementsRegistry, Canadian bulk freight
DocumentationValid · issued 9 August 2025 · expires 30 September 2026
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24488 - Convention (Subpart B), Gross Ton
10441 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 34

8 February 2026 Annual Inspection · MSP Select Annual Oversight
Physical examination · Activities Europe · Activity 8306988
24 December 2025 Administrative Inspection
Administrative · Activities Europe · Activity 8287079
15 December 2025 Administrative Inspection
Administrative · Activities Europe · Activity 8283320
25 June 2025 Administrative Inspection
Administrative · Activities Europe · Activity 8167711
19 October 2024 MTSA/ISPS Verification · MSP Select COI Oversight · COI Inspection
Physical examination · Activities Europe · Activity 8017690
5 July 2024 Administrative Inspection
Administrative · Activities Europe · Activity 7951323
9 June 2024 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8000811
3 January 2024 Annual Inspection · MSP Annual Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7844566
3 December 2023 Administrative Inspection
Administrative · Activities Europe · Activity 7833143
13 October 2023 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7809484
21 July 2023 Administrative Inspection
Administrative · Activities Europe · Activity 7751639
20 June 2023 Administrative Inspection
Administrative · Activities Europe · Activity 7718640
24 January 2023 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7626426
11 January 2023 MSP COI Oversight · Annual Inspection · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 7619769
2 January 2023 Administrative Inspection
Administrative · Activities Europe · Activity 7615322
1 December 2022 Administrative Inspection
Administrative · Activities Europe · Activity 7602569
8 October 2022 Administrative Inspection
Administrative · Activities Europe · Activity 7583272
12 September 2022 Type not recorded
No type recorded · Activities Europe · Activity 7560140
20 June 2022 Administrative Inspection
Administrative · Activities Europe · Activity 7482269
31 January 2022 MSP Annual Oversight · Annual Inspection · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 7390113
19 April 2021 MSP Periodic Oversight · Administrative Inspection · Annual Inspection
Physical examination · Activities Europe · Activity 7178038
28 January 2021 Administrative Inspection
Administrative · Activities Europe · Activity 7132157
9 March 2020 Administrative Inspection
Administrative · Activities Europe · Activity 6922870
6 January 2020 Administrative Inspection
Administrative · Activities Europe · Activity 6883138
30 September 2019 MTSA/ISPS Verification · COI Inspection · MSP Select Handover Survey · Administrative Inspection
Physical examination · Activities Europe · Activity 6824153
19 April 2019 Internal Structural Exam · Drydock Exam
Physical examination · Activities Europe · Activity 6665847
20 January 2019 MTSA/ISPS Verification · Annual Inspection · MSP Annual Oversight
Physical examination · Activities Europe · Activity 6600046
29 December 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6604649
13 December 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6597011
29 August 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6526182
12 December 2017 Administrative Inspection · MTSA/ISPS Verification · MSP Annual Oversight · Annual Inspection
Physical examination · Activities Europe · Activity 6309135
28 November 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6314655
15 April 2017 Internal Structural Exam · Underwater Inspection in lieu of Drydock
Physical examination · Activities Europe · Activity 6124831
2 December 2016 Reflagging & Initial Certification · Deficiency Check · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 6051204

Deficiency record · 51

05 - Radio Communications › N/A - No Subsystem › Radio log (diary)
Issued 9 February 2026 Resolved
An entry at least once every thirty days that the batteries or other reserve power sources have been checked and are functioning properly. The GMDSS log was missing the monthly entry for checking the GMDSS batteries. Cite: 47 CFR 80.409(e)(7)
Action required: 10 - Deficiency Rectified
Resolved 9 February 2026
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 9 February 2026 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions. • The fire door on E Deck did not secure properly. • A cable penetration in the engine room (location) was not maintaining the fire boundary. Cite: SOLAS (2004 Cons) II-2/Reg 14.2.1.1.1
Action required: 10 - Deficiency Rectified
Resolved 9 February 2026
Resolution: Corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 February 2026 Resolved
Electrical installations shall be such that the safety of…crew and ship from electrical hazards will be ensured. • Two electrical cables in the laundry room were partially pulled out of their gland seals. • Remove dead end wire in laundry room. • Missing chafing material around overhead cable penetration in laundry room. • Identified daisy chain and improper power strip in Focsle. Cite: SOLAS (2004 Cons) II-1/Reg 40.1.3
Action required: 10 - Deficiency Rectified
Resolved 9 February 2026
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 9 February 2026 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Also, Posters or signs shall be provided on or in the vicinity of survival craft and their launching controls shall illustrate the purpose of controls and the procedures for operating the appliance and give relevant instructions and warnings and be easily seen under emergency lighting conditions. • The lower guard for the forward starboard liferaft was stuck in place and would prevent it from being launched in that position. • The liferaft launching procedures (port and stbd embarkation decks) not posted under e-lighting. Cite: SOLAS (2024 Cons) III/Reg 20.2 and 9.2
Action required: 10 - Deficiency Rectified
Resolved 9 February 2026
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 9 February 2026 Resolved
All items of lifeboat equipment shall be as small as possible and shall be packed in a suitable and compact form. Except where otherwise stated, the normal equipment of every lifeboat shall consist of anti-sickness medicine sufficient for at least 48 hours. The lifeboat did not have enough seasickness medicine for 30 passengers. The lifeboat had 240 tablets and required 360 tablets. Also, there were no dosage instructions for the medication. Cite: SOLAS (2024 Cons) III/Reg 31.1.2, LSA Code 4.4.8.21
Action required: 10 - Deficiency Rectified
Resolved 9 February 2026
Resolution: Corrected on the spot.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 9 February 2026 Resolved
The Company should establish procedures, plans and instructions, including checklists as appropriate, for key shipboard operations concerning the safety of the personnel, ship and protection of the environment. The various tasks should be defined and assigned to qualified personnel. In the Focsle, the anchor locker was left opened from a survey (bitter end) and unattended with no confined space/hazard signage posted. Cite: SOLAS (2024 Cons) XI/Reg 3.1, ISM Code Part A 7
Action required: 10 - Deficiency Rectified
Resolved 9 February 2026
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 February 2026 Resolved
Waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. Identified four non-combustible trash cans (plastic) throughout the vessel: one in the galley, one in the laundry room, and two in the engine room. Cite: SOLAS (2004 Cons) II-2/Reg 4.2
Action required: 10 - Deficiency Rectified
Resolved 9 February 2026
Resolution: Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 February 2026 Resolved
The machinery, boilers, and other pressure vessels...shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce a minimum danger to persons on board…The design shall have regard to materials used in construction, the purpose for which the equipment is intended, the working conditions to which it will be subjected and the environmental conditions on board. The service air tank data plate is illegible. Cite: SOLAS (2004 Cons) II-1/ Reg 26.1
Action required: 10 - Deficiency Rectified
Resolved 9 February 2026
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 January 2024 Resolved
Smoke detection system for the cargo holds is showing an active fault. Clear fault and restore to normal operations. SOLAS II-2
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 February 2024
Resolution: ABS Assigned a finding number and assumed responsibility for this deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 January 2024 Resolved
Illustrations and instructions in appropriate languages shall be posted in passenger cabins and be conspicuously displayed at muster stations and other passenger spaces to inform passengers of:the method of donning lifejackets. Post donning Instructions for both the immersion suits and life jackets at the embarkation areas. SOALS III/8.4
Action required: 10 - Deficiency Rectified
Resolved 17 January 2024
Resolution: Printed and posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 3 January 2024 Resolved
Retro-reflective materials should be fitted on top of the gunwale as well as on the outside of the boat as near the gunwale as possible. The materials should be sufficiently wide and long to give a minimum area of 150 cm. Replace the retro reflective tape on the free fall lifeboat. Existing tape is badly wasted.SOLAS III / MSC.481
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 February 2024
Resolution: ABS Assigned a finding number and assumed responsibility for this deficiency.
12 - Dangerous Goods › N/A - No Subsystem › Personal protection
Issued 3 January 2024 Resolved
Personal equipment shall consist of the following,an Axe with a handle provided with high-voltage insulation. One fire Axe shall be present on each required fire fighters outfit. FSS C.3.2.2.1.5
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 February 2024
Resolution: ABS Assigned a finding number and assumed responsibility for this deficiency.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 3 January 2024 Resolved
All ships of 500 gross tonnage and above engaged on international voyages to carry portable atmosphere testing equipment/s on board the ship from 1 July 2016. Ensure that on board portable testing equipment is suitable for the depth of the tank being certified safe for entry. Current on board testing unit only have approximately 10 feet of hose which is inadequate to reach the bottom of the deepest void. This is to be completed prior to confined space entry. SOALS XI-1/7
Action required: 705 - Other - as specified
Resolved 6 February 2024
Resolution: ABS Assigned a finding number and assumed responsibility for this deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 January 2024 Resolved
A-15 Fire door: hold-back hooks not subject to central control station release are prohibited; the self closing mechanism for the galley to pantry door has been disabled. Restore to comply with the fire control plan. SOLAS II-1/9.4.1.1.5.4
Action required: 10 - Deficiency Rectified
Resolved 18 January 2024
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 3 January 2024 Resolved
A wire inboard of the 107 fuel service tank in the engine room was not properly dead ended. Remove or enclose in a junction box to minimize shock/fire hazards.SOLAS II-1/40
Action required: 10 - Deficiency Rectified
Resolved 18 January 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 January 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Make report to ABS and provide a route cause analysis as to why the main journal bearings between cylinder 3 and 4 has become dislodged on the main engine. SOLAS I-11(a)
Action required: 15 - Rectify deficiencies by next port
Resolved 25 January 2024
Resolution: Recieve a tech report summarizing repairs and replacement of the bearing in question.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 31 January 2022 Resolved
The purpose of this regulation is to maintain and monitor the effectiveness of the fire safety measures the ship is provided with. Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. MI found International Shore Connection and signage not consistent with Fire Control Plan. Provide clarification from Class on proper location of equipment and amend plan if needed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2022
Resolved 31 August 2022
Resolution: ABS Dubai surveyor provided class report with finding number.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 31 January 2022 Resolved
The purpose of this regulation is to maintain and monitor the effectiveness of the fire safety measures the ship is provided with. For this purpose, the following functional requirements shall be met: fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. Structural Fire Protection was missing on tank entrance & on bulkhead on ECR. There was also structural fire protection worn and torn down just aft of the tank entrance. (place holder) SOLAS 04 II-2/14.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 January 2022
Resolved 31 January 2022
Resolution: Structural Fire Protection was properly installed in both places
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 31 January 2022 Resolved
Oil fuel lines shall be arranged far apart from hot surfaces, electrical installations or other sources of ignition shall be screened or otherwise suitably protected to avoid oil spray or oil leakage onto the sources of ignition. Tape covering connection points on the fuel oil line on the generators were worn or missing. SOLAS 04 II-2/4.2.2.5.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 January 2022
Resolved 31 January 2022
Resolution: F/O connection points were covered with SOLAS tape.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 31 January 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel chemical storage PPE was excessively worn and not ready for use. SOLAS 04 I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 January 2022
Resolved 31 January 2022
Resolution: Vessel replaced equipment with new equipment ready for use.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 31 January 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Chemicals were not properly stored about the machinery spaces. SOLAS 04 I/11(a)
Action required: 10 - Deficiency Rectified
Due 31 January 2022
Resolved 31 January 2022
Resolution: walked machinery spaces to see all chemicals were properly stored in chemica storage locker.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - work and rest hours
Issued 31 January 2022 Resolved
For every seafarer on call, such as when a machinery space is unattended, the seafarer must have adequate compensatory rest period if the normal period of rest is disturbed by call-outs to work. Reviewed STCW work rest hours when an alarm was answered while the machinery space was unattended. 2nd A/E logged work, but did not receive adequate rest. 46 CFR 15.1111(h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2022
Resolved 29 August 2022
Resolution: Vsl rep provided documentation supporting 2AE received rest on 30Jan2022.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 January 2022 Resolved
The maintenance program of a 46 CFR 62.50-20(h) must include a checkoff list to make sure routine daily maintenance has been performed, fire and flooding hazards have been minimized, and plant status is suit- able for unattended operation. Completion of this checkoff list must be logged before leaving the plant unattended. Provide maintenance program check-off list [See 46 CFR 62.50-20 (h)] utilized for unattended plant operation. Provide log entries prior to leaving engine room unattended. Cite: 46 CFR 62.50-30 (j)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2022
Resolved 29 August 2022
Resolution: Documentation provided by vsl/port engineer showed check-list incorporated into SMS.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 January 2022 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. A power strip was utilized to recharge the flash lights in the port side fire locker. Cite: SOLAS (2004) II-1 / Reg 45.1.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2022
Resolved 31 August 2022
Resolution: ABS Dubai provided preliminary report with finding number.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 4 November 2019 Resolved
All general alarm bells, carbon dioxide alarms, and emergency lights shall be marked in accordance with 46 CFR Part 97. Provide required markings for all items on board the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2019
Resolved 6 January 2020
Resolution: Received email confirmation with statement from [name withheld] that the two remaining outstanding deficiencies from MSP Select Handover Survey, MISLE Activity #6876530 have been rectified (see Documents for further information).
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 30 September 2019 Resolved
2 fire hose nozzles partially clogged on Port Bridge Wing.
Action required: 10 - Deficiency Rectified
Due 4 November 2019
Resolved 4 November 2019
Resolution: Nozzles replaced and all others tested sat.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 30 September 2019 Resolved
Indicator was off by 4 degrees from actual.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2019
Resolved 27 November 2019
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 30 September 2019 Resolved
Multiple plans noted on board, but none were identified as a primary, approved plan from class.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2019
Resolved 6 January 2020
Resolution: Received email confirmation with statement from [name withheld] that the two remaining outstanding deficiencies from MSP Select Handover Survey, MISLE Activity #6876530 have been rectified (see Documents for further information).
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 30 September 2019 Resolved
Soft patch found on sewage flushing line covering a hole.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2019
Resolved 5 November 2019
Resolution: T joint was replaced with new fitting to satisfaction of MI.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 September 2019 Resolved
CO2 alarm in hold 1 found broken and detached from mount.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2019
Resolved 27 November 2019
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 30 September 2019 Resolved
Cable penetration found missing stuffing for A-60 bulkhead
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2019
Resolved 27 November 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 September 2019 Resolved
Self Closing door to E/R access was not able to close on its own.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2019
Resolved 5 November 2019
Resolution: Door closer adjusted and door closes properly as witnessed by MI
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 30 September 2019 Resolved
Remote fuel shut offs for Op zone 5 quick-closing valves were not able to close when actuated.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2019
Resolved 5 November 2019
Resolution: Pneumatic system and valves were tightened/repaired and tested sat for MI.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 12 December 2017 Resolved
Ship was unable to successfully test the emergency fire pump as requested during the inspection due to mechanical failure of the pump.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 December 2017
Resolved 13 December 2017
Resolution: ACTEUR received email from vessel represtative with report from attending ABS Surveyor stating satisfactory repair and operational test was witnessed (see report in Documents for further information).
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 12 December 2017 Resolved
Required vessel to provide documentation from attending Class Surveyor attesting to satisfactory alteration made to the drain piping to the oil settling tank in the oil purifier space (see photos in Documents for further information).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2018
Resolved 3 January 2018
Resolution: Received ABS survey report attesting to satisfactory piping repairs (see Documents for supporting information).
Fire Fighting › Fire Pumps › Pressure
Issued 28 December 2016 Resolved
Vessel could not prove proper operation of the emergency fire pump.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 December 2016
Resolved 3 January 2017
Resolution: Class attested to the proper operation of the emergency fire pump.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 28 December 2016 Resolved
Provide fire rating certificate for newly installed fire doors for the hospital, linnen locker and engine room.
Action required: 705 - Other - as specified
Due 27 January 2017
Resolved 3 January 2017
Resolution: Vessel provided certificates.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 28 December 2016 Resolved
Install proper latching/locking mechanisms for all fire doors.
Due 27 January 2017
Resolved 3 January 2017
Resolution: Class attested to the repair of all fire doors.
Engineering › Steam System (auxiliary) › Valve, Control
Issued 28 December 2016 Resolved
Prove proper operation of the auxiliary boiler water level control.
Due 21 March 2017
Resolved 22 March 2017
Resolution: Vessel installed new level control for boiler.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 28 December 2016 Resolved
Make repairs to the hydraulic leak on the aft cargo crane.
Due 21 January 2017
Resolved 3 January 2017
Resolution: Class attested to the repairs.
Electrical › Lighting (service) › Lighting Fixture
Issued 28 December 2016 Resolved
Provide and install intrinsically safe lighting and electrical connections in way of areas used for the stowage of dangerous cargoes.
Due 21 January 2017
Resolved 3 January 2017
Resolution: Class stated that this has been corrected.
Electrical › Electric Generation Source (emergency) › Switch
Issued 28 December 2016 Resolved
Provide a contigency plan to ensure power is shifted to emergency diesel generator power wihtin 45 seconds upon initial main power loss.
Action required: 15 - Rectify deficiencies by next port
Due 28 December 2017
Resolved 3 January 2017
Resolution: Vessel provided contingency plan but eventually was not needed due to the repairs of the EDG.
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 28 December 2016 Resolved
Provide PSTPs approval letter from ABS or MSC.
Due 21 March 2017
Resolved 22 March 2017
Resolution: Vessel submitted PSTPs to class for approval.
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 28 December 2016 Resolved
The vessel is granted interim approval to operator as a periodically unattended Machinery Space. During this period the vessel will be reevaluated at the next scheduled dry-dock on reliable operation and maintenance.
Due 25 June 2017
Resolved 10 June 2019
Resolution: Updated PSTP provided, engineers assitance alarm installed and tested, and maintenance program reviewed, all sat.
Communications › Alarms/Indicators › Refrigerated Spaces Alarm System
Issued 28 December 2016 Resolved
Prove proper operation of the refrigeration alarms.
Due 21 February 2017
Resolved 20 January 2017
Resolution: Vessel repaired alarms, witnessed by class.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 28 December 2016 Resolved
Remove storage from the bottom of the deck in main staircase tower.
Due 28 January 2017
Resolved 3 January 2017
Resolution: Class attested to the boxes being removed.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 28 December 2016 Resolved
Repair deck drains throughout the vessel.
Due 27 March 2017
Resolved 22 March 2017
Resolution: Vessel replaced deck drainage with new piping.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 28 December 2016 Resolved
Provide a contigency plan for missing smoke detector in the paint locker.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 December 2017
Resolved 3 January 2017
Resolution: Vessel provide a contingency plan to have a watch stander check the locker every 4 hours
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 28 December 2016 Resolved
Install an intrinsically safe smoke detector in the paint locker.
Due 21 February 2017
Resolved 20 January 2017
Resolution: Vessel installed new alarm, witnessed by class.
Construction/Loadline › Structures › Superstructure
Issued 28 December 2016 Resolved
Make repairs to the weathertight doors on the A deck.
Due 27 January 2017
Resolved 3 January 2017
Resolution: Class atteested to repairs to the doors.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 2 December 2016 Resolved
Prove transitional power with the EDG to automatically start and supply the required output within 45 sec.
Due 21 January 2017
Resolved 3 January 2017
Resolution: Class attested to the repairs of the EDG.

Casualty record · 1

12 September 2022Routine · role: Involved in a Marine Casualty · activity 7560140
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.