Records from 2016 to 2024. Most recent: inspection, 25 February 2024.
Documentation record
Tonnage as PSIX records it110402 - Regulatory (Subpart C or D), Net Ton
161963 - Regulatory (Subpart C or D), Gross Ton
161963 - Convention (Subpart B), Gross Ton
364452 - Displacement, Metric Ton
299999 - Dead Weight, Metric Ton
110402 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Inspection history · 10
25 February 2024
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7869783
3 July 2023
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7730515
14 June 2023
COC-TVE Annual · PSC B
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7710597
27 June 2022
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7488754
20 June 2022
COC-TVE Renew · PSC B · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7477222
29 December 2020
PSC B · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7109663
18 July 2019
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6754124
16 July 2019
COC-TVE Renew · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6735623
12 December 2016
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6056651
28 July 2016
COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5948470
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 25 February 2024
Resolved
The auxiliary steering gear shall be of adequate strength and capable of steering the ship at navigable speed and of being brought speedily in action in an emergency. Vessel reported inoperable #2 emergency steering gear pump.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 February 2024
Resolution: Dispatch recieved class report from the vessel authenticating the proper functioning of the #2 emergency steering gear pump
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 July 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported inoperable ICU on No.2 cylinder during a Main Engine test.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 3 July 2023
Resolved 3 July 2023
Resolution: ICU on No.2 Cylinder replaced and in good working condition. Class report submitted attests to satisfactroy repairs.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 14 June 2023
Resolved
One or more pressure/ vacuum breaking devices shall be provided to prevent the cargo tanks from being subject to the negative pressure in excess of 700mm water gauge. Number 3P PV valve found to be venting cargo fumes from the vacuum side of valve.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2023
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 14 June 2023
Resolved
The tank overfill alarm required by paragraph (a) of this section must be identified with the legend "TANK OVERFILL ALARM" In black letters at least 50.8mm high on a white background. Deck overfill alarm found to be identified with red letters.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2023
Resolved 20 June 2023
Resolution: Installed new signage for tank overfill alarm.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 27 June 2022
Resolved
Following installation, the master, owner, operator, agent, or person in charge of the vessel must properly maintain the BWMS in accordance with all manufacturer specifications. Vessel's ballast water management system is inoperable. Vessel shall not discharge ballast water into U.S. Waters. 33 CFR 151.2025(a)(1)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 July 2022
Resolution: Vessel provided tech report attesting to repairs and proper operation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 June 2022
Resolved
In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable to the organization.
Cargo pumps one, two, and three have improper electrical installation. Forward bosun hole str light is improperly terminated.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 20 June 2022
Resolved 29 June 2022
Resolution: observed repair