Records from 2016 to 2025. Most recent: inspection, 21 February 2025.
Inspection history · 5
21 February 2025
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8078639
11 February 2025
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8078343
9 September 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6808947
4 September 2019
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6797846
15 November 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6037717
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 February 2025
Resolved
FIRE DOORS IN MAIN VERTICAL ZONE BULKHEADS, GALLEY BOUNDARIES AND STAIRWAY ENCLOSURES OTHER THAN POWER-OPERATED WATERTIGHT DOORS AND THOSE WHICH ARE NORMALLY LOCKED SHALL SATISFY THE FOLLOWING REQUIREMENTS: THE DOORS SHALL BE SELF-CLOSING AND BE CAPABLE OF CLOSING WITH AN ANGLE OF INCLINATION OF UP TO 3.5 OPPOSING CLOSURE...PSCO OBSERVED 02 CLASS A FIRE DOORS IN THE ENGINE ROOM AND TO THE GALLEY DID NOT CLOSE AND LATCH.
74SOLAS(09)11-2/4.1.1.4.1
10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 February 2025
Resolved 21 February 2025
Resolution: Fire doors were fixed and made to be self-closing and properly latch during inspection.
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 21 February 2025
Resolved
ON ALL SHIPS, WITHIN THE MACHINERY SPACES, EMERGENCY ESCAPE BREATHING DEVICES SHALL BE SITUATED READY FOR USE AT EASILY VISIBLE PLACES...PSCO OBSERVED ONE EEBD AT THE LOWER LEVEL OF THE ENGINE ROOM WITHOUT AIR PRESSURE.
74SOLAS(09)11-2/13.4.3.1
10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 February 2025
Resolved 21 February 2025
Resolution: EEBD was replaced with a spare during time of inspection.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 4 September 2019
Resolved
04114
Emergency Systems
Where the emergency source of electrical power is a generator, it shall be started automatically upon failure of the main source of electrical power supply.
PSCO noted that the emergency generator starter is broken and failed to start during the inspection.
SOLAS 74 (2014) II-1/43.3.1.2
60ac
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 11 September 2019
Resolved 5 September 2019
Resolution: Received, reviewed and accepted class report from ABS stating the deficiency was rectified. Emergency generator electric starter was replaced, tested on load, and performed satisfactory.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 4 September 2019
Resolved
15108
Safety Management System
Whenever there is a hazardous condition either on board a vessel or caused by a vessel or its operation, the owner, agent, master, operator or person in charge must immediately notify the nearest Coast Guard Sector Office.
PSCO observed that the vessel did not notify the nearest Coast Guard Sector Office about the inoperable emergency generator. The vessel will provide corrective action plan with concurrence with from administration within 30 days.
33 CFR 160.216(a)
50bc
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2019
Resolved 11 February 2025
14 - Pollution Prevention › 147 - Anti-Fouling › Other (AFS)
Issued 4 September 2019
Resolved
14799
Other (AFS)
The master, owner, operator or person in charge of any vessel equipped with ballast water tanks that operates in the waters of the United States must remove fouling organisms from the vessel's hull, piping, and tanks on a regular basis and dispose of any removed substances in acceptance with local, State, and Federal regulations. PSCO observed excessive growth of fouling organisms on both port and starboard side of the vessel's hull, as well as on the stern.
33 CFR 151.2050(c)
40c
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 November 2019
Resolved 11 February 2025